Double balloon enteroscopy and capsule endoscopy for obscure gastrointestinal bleeding: An updated meta-analysis

被引:205
|
作者
Teshima, Christopher W. [1 ,2 ]
Kuipers, Ernst J. [1 ]
van Zanten, Sander Veldhuyzen [2 ]
Mensink, Peter B. F. [1 ]
机构
[1] Erasmus MC Univ, Med Ctr, Dept Gastroenterol & Hepatol, Rotterdam, Netherlands
[2] Univ Alberta, Div Gastroenterol, Edmonton, AB, Canada
关键词
capsule endoscopy; double balloon endoscopy; gastrointestinal endoscopy; gastrointestinal hemorrhage; meta-analysis; small intestine; SMALL-BOWEL; DIAGNOSTIC YIELD; MANAGEMENT; STARD;
D O I
10.1111/j.1440-1746.2010.06530.x
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background and Aim: Uncertainty remains about the best test to evaluate patients with obscure gastrointestinal bleeding (OGIB). Previous meta-analyses demonstrated similar diagnostic yields with capsule endoscopy (CE) and double balloon enteroscopy (DBE) but relied primarily on data from abstracts and were not limited to bleeding patients. Many studies have since been published. Therefore, we performed a new meta-analysis comparing CE and DBE focused specifically on OGIB. Methods: A comprehensive literature search was performed of comparative studies using both CE and DBE in patients with OGIB. Data were extracted and analyzed to determine the weighted pooled diagnostic yields of each method and the odds ratio for the successful localization of a bleeding source. Results: Ten eligible studies were identified. The pooled diagnostic yield for CE was 62% (95% confidence interval [CI] 47.3-76.1) and for DBE was 56% (95% CI 48.9-62.1), with an odds ratio for CE compared with DBE of 1.39 (95% CI 0.88-2.20; P = 0.16). Subgroup analysis demonstrated the yield for DBE performed after a previously positive CE was 75.0% (95% CI 60.1-90.0), with the odds ratio for successful diagnosis with DBE after a positive CE compared with DBE in all patients of 1.79 (95% CI 1.09-2.96; P = 0.02). In contrast, the yield for DBE after a previously negative CE was only 27.5% (95% CI 16.7-37.8). Conclusions: Capsule endoscopy and double balloon enteroscopy provide similar diagnostic yields in patients with OGIB. However, the diagnostic yield of DBE is significantly higher when performed in patients with a positive CE.
引用
收藏
页码:796 / 801
页数:6
相关论文
共 50 条
  • [41] Double Balloon Enteroscopy (DBE) Compared to Capsule Endoscopy (CE) Among Patients with Obscure Gastrointestinal Bleeding (OGIB): A Multicenter US Experience
    Mehdizadeh, Shahab
    Ross, Andrew S.
    Leighton, Jonathan
    Kamal, Ahmad
    Chen, Ann
    Schembre, Drew
    Binmoeller, Kenneth
    Kozarek, Richard
    Waxman, Irving
    Gerson, Lauren
    Jones, Brad
    Semrad, Carol
    Lo, Simon K.
    GASTROINTESTINAL ENDOSCOPY, 2006, 63 (05) : AB91 - AB91
  • [42] A prospective, single-blind trial comparing wireless capsule endoscopy and double-balloon enteroscopy in patients with obscure gastrointestinal bleeding
    Kameda, Natsuhiko
    Higuchi, Kazuhide
    Shiba, Masatsugu
    Machida, Hirohisa
    Okazaki, Hirotoshi
    Yamagami, Hirokazu
    Tanigawa, Tftsuya
    Watanabe, Kenji
    Watanabe, Toshio
    Tominaga, Kazunari
    Fujiwara, Yasuhiro
    Oshitani, Nobuhide
    Arakawa, Tetsuo
    JOURNAL OF GASTROENTEROLOGY, 2008, 43 (06) : 434 - 440
  • [43] A prospective, single-blind trial comparing wireless capsule endoscopy and double-balloon enteroscopy in patients with obscure gastrointestinal bleeding
    Natsuhiko Kameda
    Kazuhide Higuchi
    Masatsugu Shiba
    Hirohisa Machida
    Hirotoshi Okazaki
    Hirokazu Yamagami
    Tetsuya Tanigawa
    Kenji Watanabe
    Toshio Watanabe
    Kazunari Tominaga
    Yasuhiro Fujiwara
    Nobuhide Oshitani
    Tetsuo Arakawa
    Journal of Gastroenterology, 2008, 43 : 434 - 440
  • [44] Degree of Concordance Between Single Balloon Enteroscopy and Capsule Endoscopy for Obscure Gastrointestinal Bleeding Aft er an Initial Positive Capsule
    Nieves, Javier
    Lipka, Seth
    Shiani, Ashok
    Fahmi, Kerolos
    Mustafa, Sahab
    Kumar, Ambuj
    Brady, Patrick
    Nieves, Javier
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2014, 109 : S587 - S588
  • [45] Single balloon enteroscopy in obscure gastrointestinal bleeding
    John, S.
    Remedios, M.
    Appleyard, M. A.
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2008, 23 : A237 - A237
  • [46] Obscure gastrointestinal bleeding: Role of videocapsule and double-balloon enteroscopy
    Cellier, Christophe
    BEST PRACTICE & RESEARCH CLINICAL GASTROENTEROLOGY, 2008, 22 (02) : 329 - 340
  • [47] Urgent Double Balloon Enteroscopy in Patients With Overt Obscure Gastrointestinal Bleeding
    Ridtitid, Wiriyaporn
    Treeprasertsuk, Sombat
    Kongkam, Pradermchai
    Angsuwatcharakon, Phonthep
    Rerknimitr, Rungsun
    Viriyautsahakul, Vichai
    Kullavanijaya, Pinit
    GASTROINTESTINAL ENDOSCOPY, 2010, 71 (05) : AB365 - AB365
  • [48] Usefulness of Double-Balloon Enteroscopy for Gastrointestinal Bleeding of Obscure Origin
    Fukumoto, Akira
    Manabe, Noriaki
    Tanaka, Shinji
    Matsumoto, Yoshiaki
    Shimamoto, Masaru
    Yamaguchi, Toshiki
    Nakao, Madoka
    Mitsuoka, Yutaka
    Ueno, Yoshitaka
    Ito, Masanori
    Chayama, Kazuaki
    GASTROINTESTINAL ENDOSCOPY, 2006, 63 (05) : AB175 - AB175
  • [49] Yield of Double Balloon Versus Spiral Enteroscopy for Obscure Gastrointestinal Bleeding
    Schembre, Drew
    Ross, Andrew S.
    GASTROINTESTINAL ENDOSCOPY, 2009, 69 (05) : AB193 - AB193
  • [50] Obscure Gastrointestinal Bleeding: Capsule or Balloon?
    Lee, Bo-In
    CLINICAL ENDOSCOPY, 2016, 49 (01) : 4 - 5