Double balloon enteroscopy and capsule endoscopy for obscure gastrointestinal bleeding: An updated meta-analysis

被引:205
|
作者
Teshima, Christopher W. [1 ,2 ]
Kuipers, Ernst J. [1 ]
van Zanten, Sander Veldhuyzen [2 ]
Mensink, Peter B. F. [1 ]
机构
[1] Erasmus MC Univ, Med Ctr, Dept Gastroenterol & Hepatol, Rotterdam, Netherlands
[2] Univ Alberta, Div Gastroenterol, Edmonton, AB, Canada
关键词
capsule endoscopy; double balloon endoscopy; gastrointestinal endoscopy; gastrointestinal hemorrhage; meta-analysis; small intestine; SMALL-BOWEL; DIAGNOSTIC YIELD; MANAGEMENT; STARD;
D O I
10.1111/j.1440-1746.2010.06530.x
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background and Aim: Uncertainty remains about the best test to evaluate patients with obscure gastrointestinal bleeding (OGIB). Previous meta-analyses demonstrated similar diagnostic yields with capsule endoscopy (CE) and double balloon enteroscopy (DBE) but relied primarily on data from abstracts and were not limited to bleeding patients. Many studies have since been published. Therefore, we performed a new meta-analysis comparing CE and DBE focused specifically on OGIB. Methods: A comprehensive literature search was performed of comparative studies using both CE and DBE in patients with OGIB. Data were extracted and analyzed to determine the weighted pooled diagnostic yields of each method and the odds ratio for the successful localization of a bleeding source. Results: Ten eligible studies were identified. The pooled diagnostic yield for CE was 62% (95% confidence interval [CI] 47.3-76.1) and for DBE was 56% (95% CI 48.9-62.1), with an odds ratio for CE compared with DBE of 1.39 (95% CI 0.88-2.20; P = 0.16). Subgroup analysis demonstrated the yield for DBE performed after a previously positive CE was 75.0% (95% CI 60.1-90.0), with the odds ratio for successful diagnosis with DBE after a positive CE compared with DBE in all patients of 1.79 (95% CI 1.09-2.96; P = 0.02). In contrast, the yield for DBE after a previously negative CE was only 27.5% (95% CI 16.7-37.8). Conclusions: Capsule endoscopy and double balloon enteroscopy provide similar diagnostic yields in patients with OGIB. However, the diagnostic yield of DBE is significantly higher when performed in patients with a positive CE.
引用
收藏
页码:796 / 801
页数:6
相关论文
共 50 条
  • [11] Degree of concordance between double-balloon enteroscopy and capsule endoscopy in obscure gastrointestinal bleeding: a multicenter study
    Marmo, R.
    Rotondano, G.
    Casetti, T.
    Manes, G.
    Chilovi, F.
    Sprujevnik, T.
    Bianco, M. A.
    Brancaccio, M. L.
    Imbesi, V.
    Benvenuti, S.
    Pennazio, M.
    ENDOSCOPY, 2009, 41 (07) : 587 - 592
  • [12] Double-Balloon Enteroscopy Following Capsule Endoscopy in the Management of Obscure Gastrointestinal Bleeding: Outcome of a Combined Approach
    Alomani, Tareq
    Shimamura, Yuto
    Akram, Hamzah
    Dargavel, Callum
    Muwanwella, Niroshan
    Chandran, Sujievvan
    Cirocco, Maria
    Basset, Nancy
    Mosko, Jeffrey D.
    Teshima, Christopher W.
    Kandel, Gabor
    Kortan, Paul P.
    May, Gary R.
    Marcon, Norman E.
    GASTROINTESTINAL ENDOSCOPY, 2016, 83 (05) : AB316 - AB316
  • [13] A Prospective Trial Comparing Wireless Capsule Endoscopy and Double-Balloon Enteroscopy in Patients with Obscure Gastrointestinal Bleeding
    Kameda, Natsuhiko
    Higuchi, Kazuhide
    Shiba, Masatsugu
    Tabuchi, Masahiko
    Sugimori, Satoshi
    Yukawa, Tomomi
    Kadouchi, Kaori
    Okazaki, Hirotoshi
    Machida, Hirohisa
    Inagawa, Makoto
    Wada, Tomoko
    Tanigawa, Tetsuya
    Yamagami, Hirokazu
    Watanabe, Kenji
    Watanabe, Toshio
    Tominaga, Kazunari
    Fujiwara, Yasuhiro
    Oshitani, Nobuhide
    Arakawa, Tetsuo
    GASTROINTESTINAL ENDOSCOPY, 2006, 63 (05) : AB162 - AB162
  • [14] Double-balloon enteroscopy following capsule endoscopy in the management of obscure gastrointestinal bleeding: Outcome of a combined approach
    Kamalaporn, Patarapong
    Cho, Sarah
    Basset, Nancy
    Cirocco, Maria
    May, Gary
    Kortan, Paul
    Kandel, Gabor
    Marcon, Norman
    CANADIAN JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2008, 22 (05): : 491 - 495
  • [15] Capsule endoscopy and push enteroscopy in the diagnosis of obscure gastrointestinal bleeding
    Ge, ZZ
    Hu, YB
    Xiao, SD
    CHINESE MEDICAL JOURNAL, 2004, 117 (07) : 1045 - 1049
  • [16] Capsule endoscopy and push enteroscopy in the diagnosis of obscure gastrointestinal bleeding
    戈之铮
    胡运彪
    萧树东
    中华医学杂志(英文版), 2004, (07) : 86 - 90
  • [17] Capsule endoscopy and push enteroscopy in the diagnosis of obscure gastrointestinal bleeding
    戈之铮
    胡运彪
    萧树东
    Chinese Medical Journal, 2004, (07)
  • [18] Double Balloon Enteroscopy vs Single Balloon Enteroscopy in Obscure Gastrointestinal Bleeding
    Landaeta, Jorge L.
    Dias, Carla
    Rodriguez, Maria J.
    GASTROINTESTINAL ENDOSCOPY, 2009, 69 (05) : AB187 - AB187
  • [19] Laparoscopic assisted balloon enteroscopy to detect obscure gastrointestinal bleeding sources missed by capsule endoscopy
    Bisogni, Damiano
    Alemanno, Giovanni
    Galli, Andrea
    Di Bella, Annamaria
    Novelli, Luca
    Innocenti, Tommaso
    Prosperi, Paolo
    JOURNAL OF MINIMAL ACCESS SURGERY, 2021, 17 (01) : 104 - 107
  • [20] Role of double balloon enteroscopy in obscure gastrointestinal bleeding
    John, Sneha
    Appleyard, Mark
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2008, 23 (07) : 994 - 996