Double balloon enteroscopy and capsule endoscopy for obscure gastrointestinal bleeding: An updated meta-analysis

被引:205
|
作者
Teshima, Christopher W. [1 ,2 ]
Kuipers, Ernst J. [1 ]
van Zanten, Sander Veldhuyzen [2 ]
Mensink, Peter B. F. [1 ]
机构
[1] Erasmus MC Univ, Med Ctr, Dept Gastroenterol & Hepatol, Rotterdam, Netherlands
[2] Univ Alberta, Div Gastroenterol, Edmonton, AB, Canada
关键词
capsule endoscopy; double balloon endoscopy; gastrointestinal endoscopy; gastrointestinal hemorrhage; meta-analysis; small intestine; SMALL-BOWEL; DIAGNOSTIC YIELD; MANAGEMENT; STARD;
D O I
10.1111/j.1440-1746.2010.06530.x
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background and Aim: Uncertainty remains about the best test to evaluate patients with obscure gastrointestinal bleeding (OGIB). Previous meta-analyses demonstrated similar diagnostic yields with capsule endoscopy (CE) and double balloon enteroscopy (DBE) but relied primarily on data from abstracts and were not limited to bleeding patients. Many studies have since been published. Therefore, we performed a new meta-analysis comparing CE and DBE focused specifically on OGIB. Methods: A comprehensive literature search was performed of comparative studies using both CE and DBE in patients with OGIB. Data were extracted and analyzed to determine the weighted pooled diagnostic yields of each method and the odds ratio for the successful localization of a bleeding source. Results: Ten eligible studies were identified. The pooled diagnostic yield for CE was 62% (95% confidence interval [CI] 47.3-76.1) and for DBE was 56% (95% CI 48.9-62.1), with an odds ratio for CE compared with DBE of 1.39 (95% CI 0.88-2.20; P = 0.16). Subgroup analysis demonstrated the yield for DBE performed after a previously positive CE was 75.0% (95% CI 60.1-90.0), with the odds ratio for successful diagnosis with DBE after a positive CE compared with DBE in all patients of 1.79 (95% CI 1.09-2.96; P = 0.02). In contrast, the yield for DBE after a previously negative CE was only 27.5% (95% CI 16.7-37.8). Conclusions: Capsule endoscopy and double balloon enteroscopy provide similar diagnostic yields in patients with OGIB. However, the diagnostic yield of DBE is significantly higher when performed in patients with a positive CE.
引用
收藏
页码:796 / 801
页数:6
相关论文
共 50 条
  • [31] Targeted double balloon enteroscopy using capsule endoscopy in obscure gastrointestinal bleeding: effectiveness and clinical outcomes in 60 consecutive patients
    Kaffes, A. J.
    Siah, C.
    Koo, J. H.
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2006, 21 : A279 - A279
  • [32] Usefulness of small bowel reexamination in obscure gastrointestinal bleeding patients with negative capsule endoscopy findings: Comparison of repeat capsule endoscopy and double-balloon enteroscopy
    Otani, Koji
    Watanabe, Toshio
    Shimada, Sunao
    Nadatani, Yuji
    Hosomi, Shuhei
    Nagami, Yasuaki
    Tanaka, Fumio
    Kamata, Noriko
    Taira, Koichi
    Yamagami, Hirokazu
    Tanigawa, Tetsuya
    Shiba, Masatsugu
    Fujiwara, Yasuhiro
    UNITED EUROPEAN GASTROENTEROLOGY JOURNAL, 2018, 6 (06) : 879 - 887
  • [33] Double balloon enteroscopy in uremic patients with obscure gastrointestinal bleeding
    Hu, M. L.
    Chiu, Y. C.
    Tai, W. C.
    Wu, K. L.
    Chuah, S. K.
    Chiou, S. S.
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2011, 26 : 247 - 247
  • [34] Degree of concordance between single balloon enteroscopy and capsule endoscopy for obscure gastrointestinal bleeding after an initial positive capsule endoscopy finding
    Shiani, Ashok
    Nieves, Javier
    Lipka, Seth
    Patel, Brijesh
    Kumar, Ambuj
    Brady, Patrick
    THERAPEUTIC ADVANCES IN GASTROENTEROLOGY, 2016, 9 (01) : 13 - 18
  • [35] A comparison between capsule endoscopy and double balloon enteroscopy using propensity score-matching analysis in patients with previous obscure gastrointestinal bleeding
    Kakiya, Yuki
    Shiba, Masatsugu
    Okamoto, Junichi
    Kato, Kunihiro
    Minamino, Hiroaki
    Ominami, Masaki
    Fukunaga, Shusei
    Nagami, Yasuaki
    Sugimori, Satoshi
    Tanigawa, Tetsuya
    Yamagami, Hirokazu
    Watanabe, Toshio
    Tominaga, Kazunari
    Fujiwara, Yasuhiro
    Arakawa, Tetsuo
    SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 2017, 52 (03) : 306 - 311
  • [36] Is There a Role for Sonde Enteroscopy in Patients with Obscure Gastrointestinal Bleeding? A Comparison with Capsule Endoscopy
    Giordano, Samuel N.
    Dilisi, Jeff
    Banwait, Kuldip
    Wild, Daniel
    Infantolino, Anthony
    Miranda, Lenore
    Conn, Mitchell
    GASTROENTEROLOGY RESEARCH, 2009, 2 (02) : 86 - 90
  • [37] Wireless capsule endoscopy compared to push enteroscopy in the management of obscure gastrointestinal bleeding
    Bolz, G
    Hartmann, D
    Hahne, M
    Adamek, HE
    Schilling, D
    Riemann, JF
    GASTROENTEROLOGY, 2003, 124 (04) : A245 - A245
  • [38] IMPACT OF A PROTOCOL INVOLVING THE RATIONAL USE OF CAPSULE ENDOSCOPY AND DOUBLE BALLOON ENTEROSCOPY ON THE COST-EFFECTIVENESS IN THE MANAGEMENT OF OBSCURE GASTROINTESTINAL BLEEDING
    Carvalho, Rafael Pasqualini
    Lima, Leonardo S.
    Silvah, Jose Henrique
    Kemp, Rafael
    dos Santos, Jose Sebastiao S.
    GASTROINTESTINAL ENDOSCOPY, 2018, 87 (06) : AB64 - AB64
  • [39] Diagnostic Yield of Capsule Endoscopy vs. Double-Balloon Endoscopy for Patients who have Undergone Total Enteroscopy with Obscure Gastrointestinal Bleeding
    Shishido, Takayoshi
    Oka, Shiro
    Tanaka, Shinji
    Aoyama, Taiki
    Watari, Ikue
    Imagawa, Hiroki
    Yoshida, Shigeto
    Chayama, Kazuaki
    HEPATO-GASTROENTEROLOGY, 2012, 59 (116) : 955 - 959
  • [40] Capsule Endoscopy (CE) Increases the Diagnostic Yield of Double Balloon Enteroscopy (DBE) in Patients Being Investigated for Obscure Gastrointestinal Bleeding (OGIB)
    Fry, Lucia C.
    Moenkemueller, Klaus
    Neumann, Helmut
    Von Arnim, Ulrike
    Bellutti, Michael
    Malfertheiner, Peter
    GASTROINTESTINAL ENDOSCOPY, 2009, 69 (05) : AB190 - AB190