Performance analysis of a novel two-stage membrane waste heat recovery system

被引:7
|
作者
Yang, Bo [1 ]
Yuan, Weixing [1 ,2 ]
机构
[1] Beihang Univ, Sch Aeronaut Sci & Engn, Lab Ergon & Environm Control, Beijing 100191, Peoples R China
[2] Beihang Univ, Ningbo Inst Technol, Aircraft & Prop Lab, Ningbo 315100, Peoples R China
基金
中国国家自然科学基金;
关键词
Flue gas; Waste heat; Total heat recovery; Membrane; Mass transfer; TUBULAR CERAMIC MEMBRANE; FLUE-GAS; WATER RECOVERY; MASS-TRANSFER; GASEOUS STREAMS; AIR; CONDENSER; MOISTURE; BOILER; POWER;
D O I
10.1016/j.applthermaleng.2022.118952
中图分类号
O414.1 [热力学];
学科分类号
摘要
There is a tremendous waste heat recovery potential for the gas boiler exhaust flue gas. Conventional condensing recovery and state-of-the-art membrane (one-stage membrane more accurately) recovery technologies have upper limit of the total heat recovery efficiency, depending on cooling source temperature. This paper innova-tively proposes a two-stage membrane waste heat recovery (2sMWHR) to enlarge the heating capacity of district heating network (DHN). The flue gas exchanges the total heat with the DHN return water and boiler fresh air in two membrane total heat exchangers (MTHX) successively. The system realizes the self-humidification of the boiler fresh air, and therefore the mass transfer potential of the boiler flue gas is elevated, without any additional energy consumption. The 2sMWHR system yields the total heat recovery efficiency of 77.0% and the system thermal efficiency (based on net caloric value of fuel) of 105.4% at the DHN water temperature of 40 degrees C. The waste heat exhausted finally to the ambience accounts for 3.6% only, in comparison with 15% when no heat recovery is employed. Owning to the coupled effect between the two MTHX, the total heat recovery performance is retained at a high level to a certain extent as the DHN water temperature rises from 40 degrees C to 60 degrees C. The total heat recovery efficiency just decreases from 77.0% to 53.5%. In comparison, both the condensing system and one-stage membrane system perform dramatic decrease from 41.8% to 14.9% and from 45.3% to 15.1%, respectively.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] A novel system of two-stage partial nitritation/hydroxyapatite (HAP)-anammox treating effluent of anaerobic membrane reactor: Performance, elemental flow and nutrient recovery potentials
    Song, Ying
    Ma, Zhen
    Qin, Yu
    Zhao, Wenzhao
    Qi, Wei-Kang
    Li, Yu-You
    RESOURCES CONSERVATION AND RECYCLING, 2022, 184
  • [42] Performance of a biomass fueled two-stage micro gas turbine (MGT) system with hot air production heat recovery unit
    Al-attab, K. A.
    Zainal, Z. A.
    APPLIED THERMAL ENGINEERING, 2014, 70 (01) : 61 - 70
  • [43] Performance optimization for two-stage thermoelectric refrigerator system driven by two-stage thermoelectric generator
    Meng, Fankai
    Chen, Lingen
    Sun, Fengrui
    CRYOGENICS, 2009, 49 (02) : 57 - 65
  • [44] MODELING AND ANALYSIS OF A TWO-STAGE ORC FOR RECOVERING WASTE HEAT OF SINGLE FLASH GEOTHERMAL CYCLE
    Aryanfar, Yashar
    Akhsheej, Arash
    Sheykh, Kasra Ataei
    Mousavi Ghasemlou, Shaban
    Garcia Alcaraz, Jorge Luis
    CT&F-CIENCIA TECNOLOGIA Y FUTURO, 2021, 11 (02): : 51 - 62
  • [45] A novel two-stage approach for cryptocurrency analysis
    Yang, Boyu
    Sun, Yuying
    Wang, Shouyang
    INTERNATIONAL REVIEW OF FINANCIAL ANALYSIS, 2020, 72
  • [46] Heat transfer and thermal performance of two-stage molten salt steam generation system
    He, Canming
    Lu, Jianfeng
    Ding, Jing
    Wang, Weilong
    Yuan, Yibo
    APPLIED ENERGY, 2017, 204 : 1231 - 1239
  • [47] Solar/waste heat driven two-stage adsorption chiller: the prototype
    Saha, BB
    Akisawa, A
    Kashiwagi, T
    RENEWABLE ENERGY, 2001, 23 (01) : 93 - 101
  • [48] Promoting the performance of district heating from waste heat recovery in China: A general solving framework based on the two-stage branch evaluation method
    Wang, Jinda
    Sun, Chunhua
    Qi, Chengying
    Zhou, Zhigang
    Zhao, Jianing
    Zheng, Jinfu
    ENERGY, 2021, 220
  • [49] PERFORMANCE ANALYSIS OF AN ENHANCED TWO-STAGE DETECTOR
    Hao, Chengpeng
    Hou, Chaohuan
    Orlando, Danilo
    2015 IEEE CHINA SUMMIT & INTERNATIONAL CONFERENCE ON SIGNAL AND INFORMATION PROCESSING, 2015, : 292 - 295
  • [50] Performance analysis of a two-stage Rao detector
    Hao, Chengpeng
    Liu, Bin
    Cai, Long
    SIGNAL PROCESSING, 2011, 91 (08) : 2141 - 2146