Performance analysis of a novel two-stage membrane waste heat recovery system

被引:7
|
作者
Yang, Bo [1 ]
Yuan, Weixing [1 ,2 ]
机构
[1] Beihang Univ, Sch Aeronaut Sci & Engn, Lab Ergon & Environm Control, Beijing 100191, Peoples R China
[2] Beihang Univ, Ningbo Inst Technol, Aircraft & Prop Lab, Ningbo 315100, Peoples R China
基金
中国国家自然科学基金;
关键词
Flue gas; Waste heat; Total heat recovery; Membrane; Mass transfer; TUBULAR CERAMIC MEMBRANE; FLUE-GAS; WATER RECOVERY; MASS-TRANSFER; GASEOUS STREAMS; AIR; CONDENSER; MOISTURE; BOILER; POWER;
D O I
10.1016/j.applthermaleng.2022.118952
中图分类号
O414.1 [热力学];
学科分类号
摘要
There is a tremendous waste heat recovery potential for the gas boiler exhaust flue gas. Conventional condensing recovery and state-of-the-art membrane (one-stage membrane more accurately) recovery technologies have upper limit of the total heat recovery efficiency, depending on cooling source temperature. This paper innova-tively proposes a two-stage membrane waste heat recovery (2sMWHR) to enlarge the heating capacity of district heating network (DHN). The flue gas exchanges the total heat with the DHN return water and boiler fresh air in two membrane total heat exchangers (MTHX) successively. The system realizes the self-humidification of the boiler fresh air, and therefore the mass transfer potential of the boiler flue gas is elevated, without any additional energy consumption. The 2sMWHR system yields the total heat recovery efficiency of 77.0% and the system thermal efficiency (based on net caloric value of fuel) of 105.4% at the DHN water temperature of 40 degrees C. The waste heat exhausted finally to the ambience accounts for 3.6% only, in comparison with 15% when no heat recovery is employed. Owning to the coupled effect between the two MTHX, the total heat recovery performance is retained at a high level to a certain extent as the DHN water temperature rises from 40 degrees C to 60 degrees C. The total heat recovery efficiency just decreases from 77.0% to 53.5%. In comparison, both the condensing system and one-stage membrane system perform dramatic decrease from 41.8% to 14.9% and from 45.3% to 15.1%, respectively.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Two-stage process for phosphorus extraction and recovery from agricultural waste
    Senguptal, Sukalyan
    Beaudry, Jeffrey
    Shashvatt, Utsav
    Blaney, Lee
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2017, 253
  • [32] Recovery of Energy and Nitrogen via Two-Stage Valorization of Food Waste
    Motavaf, Bita
    Capece, Sofia H.
    Eldor, Tomer
    Savage, Phillip E.
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2022, 61 (33) : 12064 - 12072
  • [33] Presentation of two new two-stage desiccant cooling cycles based on heat recovery and evaluation of performance based on energy and exergy analysis
    Tavakol, Peyman
    Behbahaninia, Ali
    JOURNAL OF BUILDING ENGINEERING, 2018, 20 : 455 - 466
  • [34] Theoretical performance analysis of a new hybrid air conditioning system with two-stage energy recovery in cold winter
    Yang, Yang
    Ren, Chengqin
    Tu, Min
    Luo, Baojun
    Fu, Jianqin
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2020, 117 (117) : 1 - 11
  • [35] Compressor performance of two-stage turbocharging system
    He, Yituan
    Ma, Chaochen
    Wei, Mingshan
    Zhu, Zhifu
    FRONTIERS OF MECHANICAL ENGINEERING, 2008, 3 (02) : 218 - 221
  • [36] Design and Mechanical Performance Analysis of Two-Stage Flexible Damping System
    Shi X.
    Guo Z.
    Huang Z.
    Zhou C.
    Ren Z.
    Zhendong Ceshi Yu Zhenduan/Journal of Vibration, Measurement and Diagnosis, 2024, 44 (03): : 494 - 501and618
  • [37] Design and performance analysis of two-stage ejector for the subzero refrigeration system
    Song Y.
    Wang X.
    Wang L.
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2022, 43 (09): : 34 - 43
  • [38] Theoretical Research on the Performance of Novel Two-stage Indirect Evaporative Cooling System
    Yan, Zhen
    Zhou, Yuan-Yuan
    Yu, Yan-Shun
    Wang, Fang
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2022, 43 (02): : 451 - 458
  • [39] Experimental study on an innovative multifunction heat pipe type heat recovery two-stage sorption refrigeration system
    Li, T. X.
    Wang, R. Z.
    Wang, L. W.
    Lu, Z. S.
    ENERGY CONVERSION AND MANAGEMENT, 2008, 49 (10) : 2505 - 2512
  • [40] Anaerobic digestion of citrus waste using two-stage membrane bioreactor
    Millati, Ria
    Lukitawesa
    Permanasari, Ervina Dwi
    Sari, Kartika Wulan
    Cahyanto, Muhammad Nur
    Niklasson, Claes
    Taherzadeh, Mohammad J.
    QUALITY IN RESEARCH: INTERNATIONAL SYMPOSIUM ON MATERIALS, METALLURGY, AND CHEMICAL ENGINEERING, 2018, 316