Performance analysis of a novel two-stage membrane waste heat recovery system

被引:7
|
作者
Yang, Bo [1 ]
Yuan, Weixing [1 ,2 ]
机构
[1] Beihang Univ, Sch Aeronaut Sci & Engn, Lab Ergon & Environm Control, Beijing 100191, Peoples R China
[2] Beihang Univ, Ningbo Inst Technol, Aircraft & Prop Lab, Ningbo 315100, Peoples R China
基金
中国国家自然科学基金;
关键词
Flue gas; Waste heat; Total heat recovery; Membrane; Mass transfer; TUBULAR CERAMIC MEMBRANE; FLUE-GAS; WATER RECOVERY; MASS-TRANSFER; GASEOUS STREAMS; AIR; CONDENSER; MOISTURE; BOILER; POWER;
D O I
10.1016/j.applthermaleng.2022.118952
中图分类号
O414.1 [热力学];
学科分类号
摘要
There is a tremendous waste heat recovery potential for the gas boiler exhaust flue gas. Conventional condensing recovery and state-of-the-art membrane (one-stage membrane more accurately) recovery technologies have upper limit of the total heat recovery efficiency, depending on cooling source temperature. This paper innova-tively proposes a two-stage membrane waste heat recovery (2sMWHR) to enlarge the heating capacity of district heating network (DHN). The flue gas exchanges the total heat with the DHN return water and boiler fresh air in two membrane total heat exchangers (MTHX) successively. The system realizes the self-humidification of the boiler fresh air, and therefore the mass transfer potential of the boiler flue gas is elevated, without any additional energy consumption. The 2sMWHR system yields the total heat recovery efficiency of 77.0% and the system thermal efficiency (based on net caloric value of fuel) of 105.4% at the DHN water temperature of 40 degrees C. The waste heat exhausted finally to the ambience accounts for 3.6% only, in comparison with 15% when no heat recovery is employed. Owning to the coupled effect between the two MTHX, the total heat recovery performance is retained at a high level to a certain extent as the DHN water temperature rises from 40 degrees C to 60 degrees C. The total heat recovery efficiency just decreases from 77.0% to 53.5%. In comparison, both the condensing system and one-stage membrane system perform dramatic decrease from 41.8% to 14.9% and from 45.3% to 15.1%, respectively.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Performance analysis on a novel compact two-stage sorption refrigerator driven by low temperature heat source
    Jiang, L.
    Wang, R. Z.
    Wang, L. W.
    Liu, J. Y.
    Gao, P.
    Zhu, F. Q.
    Roskilly, A. P.
    ENERGY, 2017, 135 : 476 - 485
  • [22] Research on working characteristics of composite two-stage ventilation heat recovery system with heat pipe and heat pump
    Xu, Shuxue
    Niu, Jianhui
    Ma, Guoyuan
    Wu, Junfeng
    ENERGY, 2024, 304
  • [23] Performance analysis of a novel absorption-refrigeration driven membrane condenser system for recovery of water and waste heat from flue gas
    Salilih, Elias M.
    Bamaga, Omar
    Almatrafi, Eydhah
    Abulkhair, Hani
    Alhumade, Hesham
    Bamasag, Ahmed
    Ahmed, Iqbal
    Alsaiari, Abdulmohsen
    Nurrohman, Mohammad
    Albeirutty, Mohammad
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2023, 156 : 219 - 231
  • [24] Two-Stage Radial Turbine for a Small Waste Heat Recovery Organic Rankine Cycle (ORC) Plant
    Giovannelli, Ambra
    Archilei, Erika Maria
    Salvini, Coriolano
    ENERGIES, 2020, 13 (05)
  • [25] A modular approach to study the performance of a two-stage heat pump system for drying
    Chua, KJ
    Chou, SK
    APPLIED THERMAL ENGINEERING, 2005, 25 (8-9) : 1363 - 1379
  • [26] Two-stage anaerobic digestion of food waste coupled with in situ ammonia recovery using gas membrane absorption: Performance and microbial community
    Shi, Xuchuan
    Zuo, Jiane
    Li, Bing
    Yu, Heng
    BIORESOURCE TECHNOLOGY, 2020, 297
  • [28] Two-stage Energy Recovery System for DEMO Gyrotron
    Glyavin, M.
    Manuilov, V.
    Morozkin, M.
    2018 43RD INTERNATIONAL CONFERENCE ON INFRARED, MILLIMETER, AND TERAHERTZ WAVES (IRMMW-THZ), 2018,
  • [29] Performance Analysis of Two-Stage Solid Desiccant Densely Coated Heat Exchangers
    Li, Kun-Ying
    Luo, Win-Jet
    Tsai, Bo-Yi
    Kuan, Yean-Der
    SUSTAINABILITY, 2020, 12 (18)
  • [30] Performance analysis of a novel multi-heat sinks heat pump based on two-stage ejector-compression cycle
    Shifang, Huang
    Zhou, Lu
    Liu, Jian
    Lin, Zhang
    Zhou, Qiang
    Zhang, Xiaosong
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2023, 37