Performance analysis of a novel two-stage membrane waste heat recovery system

被引:7
|
作者
Yang, Bo [1 ]
Yuan, Weixing [1 ,2 ]
机构
[1] Beihang Univ, Sch Aeronaut Sci & Engn, Lab Ergon & Environm Control, Beijing 100191, Peoples R China
[2] Beihang Univ, Ningbo Inst Technol, Aircraft & Prop Lab, Ningbo 315100, Peoples R China
基金
中国国家自然科学基金;
关键词
Flue gas; Waste heat; Total heat recovery; Membrane; Mass transfer; TUBULAR CERAMIC MEMBRANE; FLUE-GAS; WATER RECOVERY; MASS-TRANSFER; GASEOUS STREAMS; AIR; CONDENSER; MOISTURE; BOILER; POWER;
D O I
10.1016/j.applthermaleng.2022.118952
中图分类号
O414.1 [热力学];
学科分类号
摘要
There is a tremendous waste heat recovery potential for the gas boiler exhaust flue gas. Conventional condensing recovery and state-of-the-art membrane (one-stage membrane more accurately) recovery technologies have upper limit of the total heat recovery efficiency, depending on cooling source temperature. This paper innova-tively proposes a two-stage membrane waste heat recovery (2sMWHR) to enlarge the heating capacity of district heating network (DHN). The flue gas exchanges the total heat with the DHN return water and boiler fresh air in two membrane total heat exchangers (MTHX) successively. The system realizes the self-humidification of the boiler fresh air, and therefore the mass transfer potential of the boiler flue gas is elevated, without any additional energy consumption. The 2sMWHR system yields the total heat recovery efficiency of 77.0% and the system thermal efficiency (based on net caloric value of fuel) of 105.4% at the DHN water temperature of 40 degrees C. The waste heat exhausted finally to the ambience accounts for 3.6% only, in comparison with 15% when no heat recovery is employed. Owning to the coupled effect between the two MTHX, the total heat recovery performance is retained at a high level to a certain extent as the DHN water temperature rises from 40 degrees C to 60 degrees C. The total heat recovery efficiency just decreases from 77.0% to 53.5%. In comparison, both the condensing system and one-stage membrane system perform dramatic decrease from 41.8% to 14.9% and from 45.3% to 15.1%, respectively.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Simulation Study of a Two-stage Membrane Coupled Flue Gas Waste Heat Recovery System
    Yang, Bo
    Yuan, Weixin
    Hou, Jiaqi
    Zheng, Tianqi
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2022, 43 (05): : 1345 - 1350
  • [2] Optimisation of two-stage screw expanders for waste heat recovery applications
    Read, M. G.
    Smith, I. K.
    Stosic, N.
    9TH INTERNATIONAL CONFERENCE ON COMPRESSORS AND THEIR SYSTEMS, 2015, 90
  • [3] Evaluation of a heat pump coupled two-stage humidification-dehumidification desalination system with waste heat recovery
    Zhou, Shihe
    Zhang, Kechong
    Yang, Wenkuan
    Zhu, Xiaojing
    Shen, Shengqiang
    ENERGY CONVERSION AND MANAGEMENT, 2023, 278
  • [4] Analysis of two-stage waste heat recovery based on natural gas-fired boiler
    Cui, Xinying
    Zhang, Haiyan
    Guo, Jiangfeng
    Huai, Xiulan
    Xu, Min
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2019, 43 (14) : 8898 - 8912
  • [5] Two-stage heat recovery system equipped with thermoelectric elements
    Rednic, V
    Gutt, R.
    Bruj, E.
    Bot, A.
    APPLIED THERMAL ENGINEERING, 2021, 185
  • [6] RETRACTED: A novel configuration and performance for a two-stage thermoelectric heat pump system driven by a two-stage thermoelectric generator (Retracted Article)
    Chen, L.
    Meng, F.
    Sun, F.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2009, 223 (A4) : 329 - 339
  • [7] Performance analysis for two-stage TEC system driven by two-stage TEG obeying Newton's heat transfer law
    Meng, Fankai
    Chen, Lingen
    Sun, Fengrui
    MATHEMATICAL AND COMPUTER MODELLING, 2010, 52 (3-4) : 586 - 595
  • [8] Economic, thermal analysis and optimizing of a novel hybrid fuel cell and two-stage thermoelectric device for waste heat-recovery applications
    Yan, Shu-Rong
    Alanazi, Abdulaziz
    Alanazi, Mohana
    Aldawi, Fayez
    Ayed, Hamdi
    Loukil, Hassen
    Khadimallah, Mohamed Amine
    JOURNAL OF POWER SOURCES, 2024, 610
  • [9] Performance evaluation of a two-stage compression heat pump system for district heating using waste energy
    Kwon, Ohkyung
    Cha, Dongan
    Park, Chasik
    ENERGY, 2013, 57 : 375 - 381
  • [10] Modeling and performance analysis of a two-stage thermoelectric energy harvesting system from blast furnace slag water waste heat
    Xiong, Bing
    Chen, Lingen
    Meng, Fankai
    Sun, Fengrui
    ENERGY, 2014, 77 : 562 - 569