Flow injection amperometric detection of 2′-deoxyguanosine at a ruthenium oxide hexacyanoferrate modified electrode

被引:22
|
作者
Paixao, Thiago R. L. C. [1 ]
Garcia, Camila C. M. [1 ]
Medeiros, Marisa H. G. [1 ]
Bertotti, Mauro [1 ]
机构
[1] Univ Sao Paulo, Inst Quim, BR-05508900 Sao Paulo, SP, Brazil
关键词
D O I
10.1021/ac070490e
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A ruthenium oxide hexacyanoferrate (RuOHCF) modified electrode was developed. Hydrodynamic voltammetry was employed to demonstrate the remarkable electrocatalytic activity toward the oxidation of 2 '-deoxyguanosine. The RuOHCF modified electrode was used as amperometric detector for 2 '-deoxyguanosine determination in a FIA apparatus. The influence of various experimental conditions was explored for optimum analytical performance, and at these experimental conditions, the method exhibited a linear response range to 2 '-deoxyguanosine extending from 3.8 to 252 mu mol L-1 with detection limit of 94 nmol L-1. Applications in DNA samples were examined, and the results for determination of 2 '-deoxyguanosine were in good agreement with those obtained by HPLC analysis. Studies on the kinetics of the in vitro consumption of 2 '-deoxyguanosine by acetaldehyde were also performed.
引用
收藏
页码:5392 / 5398
页数:7
相关论文
共 50 条
  • [21] INVESTIGATION OF THE USE OF GLASSY CARBON ELECTRODE MODIFIED WITH RUTHENIUM HEXACYANOFERRATE FOR DETECTION OF PROCAINE
    Silva, Thalita G.
    Salles, Maiara O.
    Paixao, Thiago R. L. C.
    QUIMICA NOVA, 2015, 38 (01): : 85 - 90
  • [22] Flow injection indirect amperometric detection of ammonium ions using a clinoptilolite-modified electrode
    Walcarius, A.
    Vromman, V.
    Bessiere, J.
    Sensors and Actuators, B: Chemical, 1999, 56 (01): : 136 - 143
  • [23] FLOW-INJECTION AMPEROMETRIC DETECTION OF ANILINE WITH A PEROXIDASE MODIFIED CARBON-PASTE ELECTRODE
    DOMINGUEZSANCHEZ, P
    OSULLIVAN, CK
    MIRANDAORDIERES, AJ
    TUNONBLANCO, P
    SMYTH, MR
    ANALYTICA CHIMICA ACTA, 1994, 291 (03) : 349 - 356
  • [24] Flow injection indirect amperometric detection of ammonium ions using a clinoptilolite-modified electrode
    Walcarius, A
    Vromman, V
    Bessiere, J
    SENSORS AND ACTUATORS B-CHEMICAL, 1999, 56 (1-2) : 136 - 143
  • [25] Flow Injection Amperometric Detection of Sulfide Using a Prussian Blue Modified Glassy Carbon Electrode
    Bensu Ertek
    Dai Long Vu
    Libor Červenka
    Yusuf Dilgin
    Analytical Sciences, 2012, 28 : 1075 - 1080
  • [26] Flow Injection Amperometric Detection of Sulfide Using a Prussian Blue Modified Glassy Carbon Electrode
    Ertek, Bensu
    Vu, Dai Long
    Cervenka, Libor
    Dilgin, Yusuf
    ANALYTICAL SCIENCES, 2012, 28 (11) : 1075 - 1080
  • [27] Flow injection amperometric detection of insulin at cobalt hydroxide nanoparticles modified carbon ceramic electrode
    Habibi, Esmaeil
    Omidinia, Eskandar
    Heidari, Hassan
    Fazli, Maryam
    ANALYTICAL BIOCHEMISTRY, 2016, 495 : 37 - 41
  • [28] Amperometric Determination of Nicotine using a Composite of Palladium hexacyanoferrate incorporated Graphene oxide modified Electrode
    Yang, Cheng Yu
    Chang, Min-Hui
    Chen, Shen-Ming
    Devadas, Balamurugan
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2016, 11 (04): : 2650 - 2658
  • [29] Low-potential reduction of sulfite at a ruthenium-oxide hexacyanoferrate modified electrode
    Montes, Rodrigo H. O.
    Richter, Eduardo M.
    Munoz, Rodrigo A. A.
    ELECTROCHEMISTRY COMMUNICATIONS, 2012, 21 : 26 - 29
  • [30] COBALT(II, III)-OXIDE CHEMICALLY MODIFIED ELECTRODE AS AMPEROMETRIC DETECTOR IN FLOW-INJECTION SYSTEMS
    MANNINO, S
    COSIO, MS
    RATI, S
    ELECTROANALYSIS, 1993, 5 (02) : 145 - 148