Influence of polyaniline on the potentiometric determination of risedronate with ion-selective membranes

被引:4
|
作者
Shishkanova, Tatiana V. [1 ]
Rezacova , Anna [2 ]
Kral, Vladimir [2 ]
Gospodinova, Natalia P. [3 ]
机构
[1] Inst Chem Technol, Dept Analyt Chem, CR-16628 Prague 6, Czech Republic
[2] Zentiva Ks, Prague 10237, Czech Republic
[3] CRP Henri Tudor, Dept Adv Mat & Struct, L-4002 Esch Sur Alzette, Luxembourg
关键词
ELECTRODES; SENSORS; PAIR;
D O I
10.1039/c0ay00382d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel kind of potentiometric sensor for the determination of risedronate in pharmaceutical products is proposed. This potentiometric sensor is comprised of a poly(vinyl chloride) (PVC) membrane based on an anion-exchanger, tridodecylmethylammonium chloride (TDDMACl), and coated with a polyaniline (PAN I) layer. The potentiometric response towards a highly hydrated risedronate species was strongly promoted by the presence of the PAN! layer. In contrast to uncoated membranes, the PANI-coated membrane exhibited a sensitivity of -39.9 +/- 0.9 mV decade(-1) and the detection limit reached 0.45 mg mL(-1). The results of the potentiometric analysis of risedronate agreed with those obtained with a validated chromatographic method. The TDDMACl-based membrane coated with the PANI layer differentiated 0.94 wt % and 3.44 wt % of a specific contaminant in 1.6 mg mL(-1) risedronate.
引用
收藏
页码:1614 / 1617
页数:4
相关论文
共 50 条
  • [41] TRANSPORT IN ION-SELECTIVE MEMBRANES
    PETERSON, MA
    GREGOR, HP
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1958, 105 (03) : C53 - C53
  • [42] Properties of ion-selective electrodes with polymer membranes for ibuprofen determination
    Lenik, J
    Marczewska, B
    Wardak, C
    DESALINATION, 2004, 163 (1-3) : 77 - 83
  • [43] Potentiometric determination of thiamine bromide in pharmaceutical preparations using an ion-selective electrode
    Petukhova, IY
    Zarechenskii, MA
    Gaidukevich, AN
    JOURNAL OF ANALYTICAL CHEMISTRY, 1996, 51 (09) : 934 - 936
  • [44] ION-SELECTIVE ELECTRODES, POTENTIOMETRY, AND POTENTIOMETRIC TITRATIONS
    BUCK, RP
    ANALYTICAL CHEMISTRY, 1974, 46 (05) : R28 - R51
  • [45] POTENTIOMETRIC TITRATION WITH PAIRS OF ION-SELECTIVE ELECTRODES
    KIYANSKII, VV
    JOURNAL OF ANALYTICAL CHEMISTRY OF THE USSR, 1987, 42 (05): : 653 - 658
  • [46] A Review of the Potentiometric Samarium Ion-Selective Sensors
    Rezapour, Morteza
    Alahdadi, Iraj
    Pirali-Hamedani, Morteza
    Ganjali, Hossein
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2025, 17 (03): : 242 - 255
  • [47] POTENTIOMETRIC TITRATION OF PESTICIDES WITH ION-SELECTIVE ELECTRODES
    KIYANSKII, VV
    BURAKHTA, VA
    JOURNAL OF ANALYTICAL CHEMISTRY OF THE USSR, 1990, 45 (02): : 266 - 270
  • [48] DETERMINATION OF CITRATE BY POTENTIOMETRIC TITRATION WITH COPPER(II) AND A COPPER ION-SELECTIVE ELECTRODE
    OLIN, A
    WALLEN, B
    ANALYTICA CHIMICA ACTA, 1983, 151 (01) : 65 - 75
  • [49] Direct Potentiometric Determination of Fluoride Species by Using Ion-Selective Fluoride Electrode
    Prkic, Ante
    Giljanovic, Josipa
    Bralic, Marija
    Boban, Katarina
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (02): : 1170 - 1179
  • [50] POTENTIOMETRIC DETERMINATION OF THE BILE PHOSPHATES BY A LEAD ION-SELECTIVE MEMBRANE-ELECTRODE
    CAMPANELLA, L
    DASCENZO, G
    DEANGELIS, G
    TOMASSETTI, M
    JOURNAL OF CLINICAL CHEMISTRY AND CLINICAL BIOCHEMISTRY, 1981, 19 (08): : 629 - 630