Influence of polyaniline on the potentiometric determination of risedronate with ion-selective membranes

被引:4
|
作者
Shishkanova, Tatiana V. [1 ]
Rezacova , Anna [2 ]
Kral, Vladimir [2 ]
Gospodinova, Natalia P. [3 ]
机构
[1] Inst Chem Technol, Dept Analyt Chem, CR-16628 Prague 6, Czech Republic
[2] Zentiva Ks, Prague 10237, Czech Republic
[3] CRP Henri Tudor, Dept Adv Mat & Struct, L-4002 Esch Sur Alzette, Luxembourg
关键词
ELECTRODES; SENSORS; PAIR;
D O I
10.1039/c0ay00382d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel kind of potentiometric sensor for the determination of risedronate in pharmaceutical products is proposed. This potentiometric sensor is comprised of a poly(vinyl chloride) (PVC) membrane based on an anion-exchanger, tridodecylmethylammonium chloride (TDDMACl), and coated with a polyaniline (PAN I) layer. The potentiometric response towards a highly hydrated risedronate species was strongly promoted by the presence of the PAN! layer. In contrast to uncoated membranes, the PANI-coated membrane exhibited a sensitivity of -39.9 +/- 0.9 mV decade(-1) and the detection limit reached 0.45 mg mL(-1). The results of the potentiometric analysis of risedronate agreed with those obtained with a validated chromatographic method. The TDDMACl-based membrane coated with the PANI layer differentiated 0.94 wt % and 3.44 wt % of a specific contaminant in 1.6 mg mL(-1) risedronate.
引用
收藏
页码:1614 / 1617
页数:4
相关论文
共 50 条
  • [21] POTENTIOMETRIC DETERMINATION OF IODIPAMIDE USING AN IODIPAMIDE ION-SELECTIVE ELECTRODE
    YAO, SZ
    LIU, DZ
    NIE, LH
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1990, 8 (04) : 373 - 377
  • [22] Photocurable membranes for ion-selective light-addressable potentiometric sensor
    Ermolenko, Y
    Yoshinobu, T
    Mourzina, Y
    Levichev, S
    Furuichi, K
    Vlasov, Y
    Schöning, MJ
    Iwasaki, H
    SENSORS AND ACTUATORS B-CHEMICAL, 2002, 85 (1-2) : 79 - 85
  • [23] ION-SELECTIVE MEMBRANES
    SIMON, W
    AMMANN, D
    MORF, WE
    OESCH, U
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1984, 31 (08) : 584 - 584
  • [24] Potentiometric response of ion-selective membranes with ionic liquids as ion-exchanger and plasticizer
    Peng, Bo
    Zhu, Jingwei
    Liu, Xiaojie
    Qin, Yu
    SENSORS AND ACTUATORS B-CHEMICAL, 2008, 133 (01) : 308 - 314
  • [25] An ion-selective potentiometric sensor for hexafluoroarsenate
    A. V. Kopytin
    A. F. Zhukov
    E. G. Il’in
    Journal of Analytical Chemistry, 2015, 70 : 485 - 487
  • [26] An ion-selective potentiometric sensor for hexafluoroarsenate
    Kopytin, A. V.
    Zhukov, A. F.
    Il'in, E. G.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 70 (04) : 485 - 487
  • [27] POTENTIOMETRIC AND AMPEROMETRIC ION-SELECTIVE ELECTRODES
    GULENS, J
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1988, 195 : 124 - ANYL
  • [28] POTENTIOMETRIC DETERMINATION OF PALLADIUM IN ELECTROLYTES BY MEANS OF A LIQUID ION-SELECTIVE ELECTRODE
    VASILEV, VA
    GUREV, IA
    INDUSTRIAL LABORATORY, 1989, 55 (10): : 1108 - 1109
  • [29] DIRECT POTENTIOMETRIC WATER HARDNESS DETERMINATION USING ION-SELECTIVE ELECTRODES
    MEIER, PC
    ERNE, D
    CIMERMAN, Z
    AMMANN, D
    SIMON, W
    MIKROCHIMICA ACTA, 1980, 1 (5-6) : 317 - 327
  • [30] POTENTIOMETRIC DETERMINATION OF CHLORIDE IN PULPING LIQUORS WITH A CHLORIDE ION-SELECTIVE ELECTRODE
    PAPP, J
    SVENSK PAPPERSTIDNING-NORDISK CELLULOSA, 1972, 75 (16): : 677 - &