Influence of polyaniline on the potentiometric determination of risedronate with ion-selective membranes

被引:4
|
作者
Shishkanova, Tatiana V. [1 ]
Rezacova , Anna [2 ]
Kral, Vladimir [2 ]
Gospodinova, Natalia P. [3 ]
机构
[1] Inst Chem Technol, Dept Analyt Chem, CR-16628 Prague 6, Czech Republic
[2] Zentiva Ks, Prague 10237, Czech Republic
[3] CRP Henri Tudor, Dept Adv Mat & Struct, L-4002 Esch Sur Alzette, Luxembourg
关键词
ELECTRODES; SENSORS; PAIR;
D O I
10.1039/c0ay00382d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel kind of potentiometric sensor for the determination of risedronate in pharmaceutical products is proposed. This potentiometric sensor is comprised of a poly(vinyl chloride) (PVC) membrane based on an anion-exchanger, tridodecylmethylammonium chloride (TDDMACl), and coated with a polyaniline (PAN I) layer. The potentiometric response towards a highly hydrated risedronate species was strongly promoted by the presence of the PAN! layer. In contrast to uncoated membranes, the PANI-coated membrane exhibited a sensitivity of -39.9 +/- 0.9 mV decade(-1) and the detection limit reached 0.45 mg mL(-1). The results of the potentiometric analysis of risedronate agreed with those obtained with a validated chromatographic method. The TDDMACl-based membrane coated with the PANI layer differentiated 0.94 wt % and 3.44 wt % of a specific contaminant in 1.6 mg mL(-1) risedronate.
引用
收藏
页码:1614 / 1617
页数:4
相关论文
共 50 条
  • [11] Potentiometric determination of effective complex formation constants of lipophilic ion carriers within ion-selective electrode membranes
    Bakker, E
    Pretsch, E
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1997, 144 (05) : L125 - L127
  • [12] Influence of plasticizers on ion-selective polyimide membranes
    Totu, Eugenia
    Ruse, Elena
    Josceanu, Ana Maria
    ANNALI DI CHIMICA, 2006, 96 (3-4) : 237 - 246
  • [13] CHOICE OF ION-SELECTIVE ELECTRODES FOR THE POTENTIOMETRIC DETERMINATION OF MERCAPTANS IN CONDENSATES
    KIYANSKII, VV
    BURAKHTA, VA
    LADYGIN, VV
    JOURNAL OF ANALYTICAL CHEMISTRY OF THE USSR, 1987, 42 (06): : 908 - 910
  • [14] POTENTIOMETRIC DETERMINATION OF AMIDES AND SUBSTITUTED URACILS WITH ION-SELECTIVE ELECTRODES
    OBTEMPERANSKAYA, SI
    RASHID, S
    KASHIN, AN
    BUZLANOVA, MM
    KARANDI, IV
    JOURNAL OF ANALYTICAL CHEMISTRY OF THE USSR, 1988, 43 (08): : 1230 - 1232
  • [15] A new ion-selective electrode for potentiometric determination of Ce(III)
    Karami, H
    Mousavi, MF
    Shamsipur, M
    Yavari, I
    Alizadeh, AA
    ANALYTICAL LETTERS, 2003, 36 (06) : 1065 - 1078
  • [16] POTENTIOMETRIC DETERMINATION OF GOLD IN ELECTROLYTES USING ION-SELECTIVE ELECTRODES
    BOROVSKII, ES
    RAKHMANKO, EM
    STAROBINETS, GL
    JOURNAL OF ANALYTICAL CHEMISTRY OF THE USSR, 1985, 40 (08): : 1127 - 1130
  • [17] POTENTIOMETRIC DETERMINATION OF IODIDE IN MILK BY USE OF ION-SELECTIVE ELECTRODE
    SUCMAN, E
    SUCMANOVA, M
    SYNEK, O
    ZEITSCHRIFT FUR LEBENSMITTEL-UNTERSUCHUNG UND-FORSCHUNG, 1978, 167 (01): : 5 - 6
  • [18] POTENTIOMETRIC DETERMINATION OF HALOGENS IN ALUMINA PRODUCTION WITH ION-SELECTIVE ELECTRODES
    BLOKH, MS
    TASHUTA, GN
    KHALYAPINA, OB
    JOURNAL OF APPLIED CHEMISTRY OF THE USSR, 1992, 65 (10): : 1845 - 1849
  • [19] INDIRECT POTENTIOMETRIC DETERMINATION OF SULFIDE WITH A CADMIUM ION-SELECTIVE ELECTRODE
    CALOKERINOS, AC
    TIMOTHEOUPOTAMIA, M
    SARANTONIS, E
    HADJIIOANNOU, TP
    ANALYTICA CHIMICA ACTA, 1983, 151 (01) : 85 - 90
  • [20] POTENTIOMETRIC ION-SELECTIVE AND BIOSELECTIVE ELECTRODES BASED ON ASYMMETRIC POLYURETHANE MEMBRANES
    LIU, D
    MEYERHOFF, ME
    GOLDBERG, HD
    BROWN, RB
    ANALYTICA CHIMICA ACTA, 1993, 274 (01) : 37 - 46