Determination of Trace Metals by Anodic Stripping Voltammetry Using a Carbon Nanotube Tower Electrode

被引:77
|
作者
Guo, Xuefei [1 ]
Yun, Yeoheung [2 ]
Shanov, Vesselin N. [3 ]
Halsall, H. Brian [1 ]
Heineman, William R. [1 ]
机构
[1] Univ Cincinnati, Dept Chem, Cincinnati, OH 45221 USA
[2] N Carolina Agr & Tech State Univ, Dept Bioengn, Greensboro, NC 27411 USA
[3] Univ Cincinnati, Smart Mat Nanotechnol Lab, Dept Mech Ind & Nucl Engn, Cincinnati, OH 45221 USA
基金
美国国家科学基金会;
关键词
Carbon nanotube (CNT) array; CNT tower electrode; Osteryoung square-wave stripping voltammetry (OSWSV); Anodic stripping voltammetry (ASV); IN-SITU; CADMIUM; ELECTROCHEMISTRY; SPECIATION; LEAD;
D O I
10.1002/elan.201000674
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Anodic stripping voltammetry (ASV) trace detection of the heavy metals ions Pb(2+), Cd(2+), Cu(2+) and Zn(2+) was done at highly aligned multi-wall carbon nanotube tower electrodes (CNT tower electrodes). The CNT tower electrode is one type of CNT array that consists of millions of ordered super long CNTs. Osteryoung square-wave stripping voltammetry was used for the stripping step. This electrode material shows good resolution for individual detection of these four metal ions with calculated detection limits of 12 nM, 25 nM, 44 nM and 67 nM for Pb(2+), Cd(2+), Cu(2+) and Zn(2+), respectively, for a deposition time of 120 s. The detectable limit was as low as 0.5 nM for a 10 min deposition.
引用
收藏
页码:1252 / 1259
页数:8
相关论文
共 50 条
  • [1] Determination of trace metals by anodic stripping voltammetry using a bismuth-modified carbon nanotube electrode
    Hwang, Gil Ho
    Han, Won Kyu
    Park, Joon Shik
    Kang, Sung Goon
    TALANTA, 2008, 76 (02) : 301 - 308
  • [2] Determination of trace xanthine by anodic stripping voltammetry with carbon nanotube modified glassy carbon electrode
    Zhao, G
    Zang, SQ
    Liu, KZ
    Lin, S
    Liang, J
    Guo, XY
    Zhang, ZJ
    ANALYTICAL LETTERS, 2002, 35 (14) : 2233 - 2244
  • [3] Determination of trace tin by anodic stripping voltammetry at a carbon paste electrode
    Li, Yi-Heng
    Xie, Hong-Qi
    Zhou, Fang-Qin
    Guo, Hui-Shi
    ELECTROANALYSIS, 2006, 18 (10) : 976 - 980
  • [4] Anodic adsorptive stripping voltammetry at a carbon paste electrode for determination of trace thorium
    Liu, SM
    Li, JN
    Mao, X
    Gao, P
    ANALYTICAL LETTERS, 2003, 36 (07) : 1381 - 1392
  • [5] DETERMINATION OF TRACE ALUMINUM BY ANODIC ADSORPTIVE STRIPPING VOLTAMMETRY USING A MULTI-WALLED CARBON NANOTUBE MODIFIED CARBON PASTE ELECTRODE
    Deng, Peihong
    Fei, Junjie
    Zhang, Jun
    Feng, Yonglan
    ANALYTICAL LETTERS, 2011, 44 (08) : 1521 - 1535
  • [6] Anodic Stripping Voltammetry of Heavy Metals on a Metal Catalyst Free Carbon Nanotube Electrode
    Yue, Wei
    Riehl, Bill L.
    Pantelic, Nebojsa
    Schlueter, Kevin T.
    Johnson, Jay M.
    Wilson, Robert A.
    Guo, Xuefei
    King, Edward E.
    Heineman, William R.
    ELECTROANALYSIS, 2012, 24 (05) : 1039 - 1046
  • [7] Application of a carbon nanotube modified electrode in anodic stripping voltammetry for determination of trace amounts of 6-benzylaminopurine
    Zhao, G
    Liu, KZ
    Lin, S
    Liang, J
    Guo, XY
    Zhang, ZJ
    MICROCHIMICA ACTA, 2003, 143 (04) : 255 - 260
  • [8] Application of a Carbon Nanotube Modified Electrode in Anodic Stripping Voltammetry for Determination of Trace Amounts of 6-Benzylaminopurine
    Ge Zhao
    Kuaizhi Liu
    Song Lin
    Ji Liang
    Xinyong Guo
    Zhijun Zhang
    Microchimica Acta, 2003, 143 : 255 - 260
  • [9] Nafion Coated Silver Amalgam Electrode for Determination of Trace Metals by Anodic Stripping Voltammetry
    Strasunske, Kristina
    Mikkelsen, Oyvind
    Billon, Gabriel
    ELECTROANALYSIS, 2010, 22 (05) : 501 - 507
  • [10] DETERMINATION OF TRACE-METALS IN AQUEOUS ENVIRONMENTS BY ANODIC-STRIPPING VOLTAMMETRY WITH A VITREOUS CARBON ROTATING ELECTRODE
    MIGUEL, AH
    JANKOWSKI, CM
    ANALYTICAL CHEMISTRY, 1974, 46 (12) : 1832 - 1834