Determination of Trace Metals by Anodic Stripping Voltammetry Using a Carbon Nanotube Tower Electrode

被引:77
|
作者
Guo, Xuefei [1 ]
Yun, Yeoheung [2 ]
Shanov, Vesselin N. [3 ]
Halsall, H. Brian [1 ]
Heineman, William R. [1 ]
机构
[1] Univ Cincinnati, Dept Chem, Cincinnati, OH 45221 USA
[2] N Carolina Agr & Tech State Univ, Dept Bioengn, Greensboro, NC 27411 USA
[3] Univ Cincinnati, Smart Mat Nanotechnol Lab, Dept Mech Ind & Nucl Engn, Cincinnati, OH 45221 USA
基金
美国国家科学基金会;
关键词
Carbon nanotube (CNT) array; CNT tower electrode; Osteryoung square-wave stripping voltammetry (OSWSV); Anodic stripping voltammetry (ASV); IN-SITU; CADMIUM; ELECTROCHEMISTRY; SPECIATION; LEAD;
D O I
10.1002/elan.201000674
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Anodic stripping voltammetry (ASV) trace detection of the heavy metals ions Pb(2+), Cd(2+), Cu(2+) and Zn(2+) was done at highly aligned multi-wall carbon nanotube tower electrodes (CNT tower electrodes). The CNT tower electrode is one type of CNT array that consists of millions of ordered super long CNTs. Osteryoung square-wave stripping voltammetry was used for the stripping step. This electrode material shows good resolution for individual detection of these four metal ions with calculated detection limits of 12 nM, 25 nM, 44 nM and 67 nM for Pb(2+), Cd(2+), Cu(2+) and Zn(2+), respectively, for a deposition time of 120 s. The detectable limit was as low as 0.5 nM for a 10 min deposition.
引用
收藏
页码:1252 / 1259
页数:8
相关论文
共 50 条
  • [31] Detection of Trace Copper Metal at Carbon Nanotube Based Electrodes Using Squarewave Anodic Stripping Voltammetry
    Choi, Changkun
    Jeong, Youngsam
    Kwon, Yongchai
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2013, 34 (03) : 801 - 809
  • [32] Trace determination of molybdenum by anodic adsorptive stripping voltammetry using a multi-walled carbon nanotubes modified carbon paste electrode
    Deng, Pei-Hong
    Fei, Jun-Jie
    Feng, Yong-Lan
    SENSORS AND ACTUATORS B-CHEMICAL, 2010, 148 (01): : 214 - 220
  • [33] Determination of trace heavy metal ions by anodic stripping voltammetry using nanofibrillated cellulose modified electrode
    Zinoubi, K.
    Majdoub, H.
    Barhoumi, H.
    Boufi, S.
    Jaffrezic-Renault, N.
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2017, 799 : 70 - 77
  • [34] TRACE DETERMINATION OF PLATINUM BY DIFFERENTIAL-PULSE ANODIC-STRIPPING VOLTAMMETRY (DPASV) USING THE GLASSY-CARBON ELECTRODE
    KRITSOTAKIS, K
    TOBSCHALL, HJ
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1985, 320 (02): : 156 - 158
  • [35] Trace mercury determination by differential pulse anodic stripping voltammetry using polythiophene-quinoline/glassy carbon modified electrode
    Yoo, KS
    Woo, SB
    Jyoung, JY
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2003, 24 (01) : 27 - 31
  • [36] ANODIC-STRIPPING VOLTAMMETRY FOR THE DETERMINATION OF TRACE IODIDE
    LU, GH
    YANG, M
    ZHENG, QF
    WANG, AL
    JIN, ZX
    ELECTROANALYSIS, 1995, 7 (06) : 591 - 593
  • [37] Determination of trace amounts of copper in iron and steel by differential pulse anodic stripping voltammetry at a glassy carbon electrode
    Tanaka, T
    Adachi, M
    Ishiyama, T
    Sato, M
    Ono, A
    BUNSEKI KAGAKU, 1998, 47 (05) : 255 - 260
  • [38] Stripping voltammetry of heavy metals on a metal catalyst free carbon nanotube electrode
    Yue, Wei
    Riehl, Bill L.
    Schlueter, Kevin T.
    Heineman, William R.
    Bange, Adam
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2012, 244
  • [39] Determination of trace vanadium by adsorptive stripping voltammetry at a carbon paste electrode
    Li, Yi-Heng
    Wang, Yue-Xuan
    Huang, Mei-Hua
    ELECTROANALYSIS, 2008, 20 (13) : 1440 - 1444
  • [40] Determination of copper by anodic stripping voltammetry on a glassy carbon electrode using a continuous flow system
    J. F. van Staden
    M. Matoetoe
    Fresenius' Journal of Analytical Chemistry, 1997, 357 : 624 - 628