Determination of Trace Metals by Anodic Stripping Voltammetry Using a Carbon Nanotube Tower Electrode

被引:77
|
作者
Guo, Xuefei [1 ]
Yun, Yeoheung [2 ]
Shanov, Vesselin N. [3 ]
Halsall, H. Brian [1 ]
Heineman, William R. [1 ]
机构
[1] Univ Cincinnati, Dept Chem, Cincinnati, OH 45221 USA
[2] N Carolina Agr & Tech State Univ, Dept Bioengn, Greensboro, NC 27411 USA
[3] Univ Cincinnati, Smart Mat Nanotechnol Lab, Dept Mech Ind & Nucl Engn, Cincinnati, OH 45221 USA
基金
美国国家科学基金会;
关键词
Carbon nanotube (CNT) array; CNT tower electrode; Osteryoung square-wave stripping voltammetry (OSWSV); Anodic stripping voltammetry (ASV); IN-SITU; CADMIUM; ELECTROCHEMISTRY; SPECIATION; LEAD;
D O I
10.1002/elan.201000674
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Anodic stripping voltammetry (ASV) trace detection of the heavy metals ions Pb(2+), Cd(2+), Cu(2+) and Zn(2+) was done at highly aligned multi-wall carbon nanotube tower electrodes (CNT tower electrodes). The CNT tower electrode is one type of CNT array that consists of millions of ordered super long CNTs. Osteryoung square-wave stripping voltammetry was used for the stripping step. This electrode material shows good resolution for individual detection of these four metal ions with calculated detection limits of 12 nM, 25 nM, 44 nM and 67 nM for Pb(2+), Cd(2+), Cu(2+) and Zn(2+), respectively, for a deposition time of 120 s. The detectable limit was as low as 0.5 nM for a 10 min deposition.
引用
收藏
页码:1252 / 1259
页数:8
相关论文
共 50 条
  • [41] Determination of copper by anodic stripping voltammetry on a glassy carbon electrode using a continuous flow system
    vanStaden, JF
    Matoetoe, M
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 357 (06): : 624 - 628
  • [43] Anodic stripping voltammetry using a vibrating electrode
    Chapman, Conrad S.
    van den Berg, Constant M. G.
    ELECTROANALYSIS, 2007, 19 (13) : 1347 - 1355
  • [44] ANODIC STRIPPING VOLTAMMETRY OF TRACE METALS IN SEA-WATER
    ZIRINO, A
    LIEBERMA.S
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1972, 119 (08) : C246 - &
  • [45] Anodic stripping voltammetry of trace metals by batch injection analysis
    Brett, CMA
    Brett, AMO
    Tugulea, L
    ANALYTICA CHIMICA ACTA, 1996, 322 (03) : 151 - 157
  • [46] Anodic stripping voltammetry - ASV for determination of heavy metals
    Baron-Jaimez, J.
    Joya, M. R.
    Barba-Ortega, J.
    2ND INTERNATIONAL MEETING FOR RESEARCHERS IN MATERIALS AND PLASMA TECHNOLOGY, 2013, 466
  • [47] Double Deposition and Stripping Steps for Trace Determination of Au(III) Using Anodic Stripping Voltammetry
    Rutyna, Iwona
    Ochab, Mateusz
    Korolczuk, Mieczyslaw
    ELECTROANALYSIS, 2015, 27 (10) : 2486 - 2491
  • [48] DETERMINATION OF TRACE AMOUNTS OF HEAVY-METALS IN AGRICULTURAL BY-PRODUCTS USING ANODIC-STRIPPING VOLTAMMETRY
    LIPPOLIS, MT
    CONCIALINI, V
    GALLETTI, GC
    PICCAGLIA, R
    ANALYST, 1989, 114 (12) : 1621 - 1622
  • [49] HIGHLY SELECTIVE SENSOR FOR TRACE ASENITE DETERMINATION USING ANODIC STRIPPING VOLTAMMETRY
    Wang, Li
    Jing, Gaoshan
    Lu, Wenshuai
    Cui, Tianhong
    2016 IEEE 29TH INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS (MEMS), 2016, : 901 - 904
  • [50] Trace determination of vardenafil hydrochloride in commercial formulation and human serum by adsorptive anodic stripping voltammetry at a carbon paste electrode
    Mohamed M. Ghoneim
    Amera M. Hassanein
    Nehal A. Salahuddin
    Hanaa S. El-Desoky
    Mona N. Elfiky
    Journal of Solid State Electrochemistry, 2013, 17 : 1891 - 1902