Determination of trace xanthine by anodic stripping voltammetry with carbon nanotube modified glassy carbon electrode

被引:33
|
作者
Zhao, G
Zang, SQ
Liu, KZ [1 ]
Lin, S
Liang, J
Guo, XY
Zhang, ZJ
机构
[1] Henan Univ, Dept Chem, Kaifeng 475001, Peoples R China
[2] Tsinghua Univ, Dept Mech, Beijing 100084, Peoples R China
[3] Henan Univ, Key Lab Lubricat & Funct Mat, Kaifeng 475001, Peoples R China
关键词
anodic stripping voltammetry; carbon nanotubes; chemically modified electrode; xanthine determination;
D O I
10.1081/AL-120016098
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The electrochemistry of xanthine (Xa) was studied by CV at a glassy carbon electrode modified with carbon nanotubes. A well defined, sensitive oxidation wave of xanthine and a small reduction wave were obtained. Based on the oxidation peak, a method for determination of xanthine with semi-derivative anodic stripping voltammetry at a glassy carbon electrode modified with carbon nanotubes was investigated. The stripping peak current is proportional to the concentration of Xa over the range 2.0 x 10(-7) -2.0 x 10(-5) M with 1-min accumulation. The detection limit is 4.0 x 10(-9) mol/L with 3-min accumulation. The method has been successfully applied to the determination of xanthine in human serum.
引用
收藏
页码:2233 / 2244
页数:12
相关论文
共 50 条
  • [1] Determination of trace metoclopramide by anodic stripping voltammetry with nafion modified glassy carbon electrode
    Wang, ZH
    Zhang, HZ
    Zhou, SP
    Dong, WJ
    TALANTA, 2001, 53 (06) : 1133 - 1138
  • [2] Ultra-Sensitive Anodic Stripping Voltammetry for the Determination of Xanthine at a Glassy Carbon Electrode
    Mohamed S. Ibrahim
    Yassien M. Temerk
    Moustafa M. Kamal
    Gamal A.-W. Ahmed
    Hossieny S. M. Ibrahim
    Microchimica Acta, 2004, 144 : 249 - 256
  • [3] Ultra-sensitive anodic stripping voltammetry for the determination of xanthine at a glassy carbon electrode
    Ibrahim, MS
    Temerk, YM
    Kamal, MM
    Ahmed, GAW
    Ibrahim, HSM
    MICROCHIMICA ACTA, 2004, 144 (04) : 249 - 256
  • [4] Determination of trace metals by anodic stripping voltammetry using a bismuth-modified carbon nanotube electrode
    Hwang, Gil Ho
    Han, Won Kyu
    Park, Joon Shik
    Kang, Sung Goon
    TALANTA, 2008, 76 (02) : 301 - 308
  • [5] Determination of Trace Metals by Anodic Stripping Voltammetry Using a Carbon Nanotube Tower Electrode
    Guo, Xuefei
    Yun, Yeoheung
    Shanov, Vesselin N.
    Halsall, H. Brian
    Heineman, William R.
    ELECTROANALYSIS, 2011, 23 (05) : 1252 - 1259
  • [6] Determination of mercury at a dithizone-modified glassy carbon electrode by anodic stripping voltammetry
    Huang, WS
    Zhang, SH
    ANALYTICAL SCIENCES, 2002, 18 (02) : 187 - 189
  • [7] Determination of Mercury at a Dithizone-Modified Glassy Carbon Electrode by Anodic Stripping Voltammetry
    Wensheng Huang
    Shenghui Zhang
    Analytical Sciences, 2002, 18 : 187 - 189
  • [8] Application of a carbon nanotube modified electrode in anodic stripping voltammetry for determination of trace amounts of 6-benzylaminopurine
    Zhao, G
    Liu, KZ
    Lin, S
    Liang, J
    Guo, XY
    Zhang, ZJ
    MICROCHIMICA ACTA, 2003, 143 (04) : 255 - 260
  • [9] Application of a Carbon Nanotube Modified Electrode in Anodic Stripping Voltammetry for Determination of Trace Amounts of 6-Benzylaminopurine
    Ge Zhao
    Kuaizhi Liu
    Song Lin
    Ji Liang
    Xinyong Guo
    Zhijun Zhang
    Microchimica Acta, 2003, 143 : 255 - 260
  • [10] Determination of mercury by anodic stripping voltammetry with a gold nanoparticle-modified glassy carbon electrode
    Abollino, Ornella
    Giacomino, Agnese
    Malandrino, Mery
    Piscionieri, Giuseppina
    Mentasti, Edoardo
    ELECTROANALYSIS, 2008, 20 (01) : 75 - 83