Improvements in PET Image Quality in Time of Flight (TOF) Simultaneous PET/MRI

被引:27
|
作者
Minamimoto, Ryogo [1 ,2 ]
Levin, Craig [2 ]
Jamali, Mehran [1 ,2 ]
Holley, Dawn [3 ]
Barkhodari, Amir [1 ]
Zaharchuk, Greg [3 ]
Iagaru, Andrei [1 ]
机构
[1] Stanford Univ, Div Nucl Med & Mol Imaging, Dept Radiol, 300 Pasteur Dr,H2200, Stanford, CA 94305 USA
[2] Stanford Univ, Mol Imaging Program Stanford, Dept Radiol, Stanford, CA 94305 USA
[3] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
关键词
PET/MRI; PET/CT; Time of flight; Artifact; Image quality; EMISSION TOMOGRAPHY/COMPUTED TOMOGRAPHY; ATTENUATION CORRECTION; RESPIRATORY MOTION; CLINICAL-EXPERIENCE; DENTAL IMPLANTS; ARTIFACTS; ATLAS; MRI; REGISTRATION; GENERATION;
D O I
10.1007/s11307-016-0939-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
An integrated positron emission tomography (PET)/magnetic resonance imaging (MRI) scanner with time of flight (TOF) technology is now available for clinical use. The aim of this study is to evaluate the potential of TOF PET in PET/MRI to reduce artifacts in PET images when compared to non-TOF PET/MRI, TOF PET/X-ray computed tomography (CT), and non-TOF PET/CT. All patients underwent a single 2-deoxy-2-[F-18]fluoro-d-glucose ([F-18]FDG) injection, followed first by PET/CT, and subsequently by PET/MRI. PET/CT exams were requested as standard-of-care for oncological indications. Using the PET acquisitions datasets, 4 series of images (TOF PET/CT, non-TOF PET/CT, TOF PET/MRI, and non-TOF PET/MRI) were reconstructed. These image series were visually evaluated for: (1) dental metal artifacts, (2) breathing artifacts, and (3) pelvic artifacts due to scatter correction errors from high bladder [F-18]FDG concentration. PET image quality was assessed by a 3-point scale (1-clinically significant artifact, 2-non clinically significant artifact, and 3-no artifact). Twenty-five patients (mean +/- SD age: 56 +/- 13 years old; female: 10, male: 15) were enrolled. TOF PET/MRI, non-TOF PET/MRI, TOF PET/CT, and non-TOF PET/CT scores 2.8, 2.5, 2.4, and 2.3, respectively for the presence of dental artifacts, 2.8, 2.5, 2.2, and 1.9, respectively, for the presence of breathing artifacts, and 2.7, 1.7, 2.0, and 1.3, respectively, for the presence of pelvic artifacts TOF PET/MRI images showed the highest image quality scores among the 4 datasets of PET images. The superior timing resolution and resulting TOF capability of the new PET/MRI scanner improved PET image quality in this cohort by reducing artifacts compared to non-TOF PET/MRI, TOF PET/CT, and non-TOF PET/CT.
引用
收藏
页码:776 / 781
页数:6
相关论文
共 50 条
  • [41] Noise contamination from PET blood sampling pump: Effects on structural MRI image quality in simultaneous PET/MR studies
    Bartlett, Elizabeth
    DeLorenzo, Christine
    Parsey, Ramin
    Huang, Chuan
    MEDICAL PHYSICS, 2018, 45 (02) : 678 - 686
  • [42] Deep-TOF-PET: Deep learning-guided generation of time-of-flight from non-TOF brain PET images in the image and projection domains
    Sanaat, Amirhossein
    Akhavanalaf, Azadeh
    Shiri, Isaac
    Salimi, Yazdan
    Arabi, Hossein
    Zaidi, Habib
    HUMAN BRAIN MAPPING, 2022, 43 (16) : 5032 - 5043
  • [43] Fisher Information-Based Evaluation of Image Quality for Time-of-Flight PET
    Vunckx, Kathleen
    Zhou, Lin
    Matej, Samuel
    Defrise, Michel
    Nuyts, Johan
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2010, 29 (02) : 311 - 321
  • [44] PET IMAGE QUALITY IN COMMONLY USED ISOTOPES AND IN VIVO VALIDATION OF A NEW PET INSERT FOR PET/MRI
    Chen, Anne
    INTERNAL MEDICINE JOURNAL, 2023, 53 : 33 - 35
  • [45] Fisher information-based evaluation of image quality for time-of-flight PET
    Vunckx, Kathleen
    Zhou, Lin
    Matej, Samuel
    Defrise, Michel
    Nuyts, Johan
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 4129 - +
  • [46] Simultaneous Reconstruction of Activity and Attenuation in Time-of-Flight PET
    Rezaei, Ahmadreza
    Nuyts, Johan
    Defrise, Michel
    Bal, Girish
    Michel, Christian
    Conti, Maurizio
    Watson, Charles
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 2375 - 2382
  • [47] Simultaneous Reconstruction of Activity and Attenuation in Time-of-Flight PET
    Rezaei, Ahmadreza
    Defrise, Michel
    Bal, Girish
    Michel, Christian
    Conti, Maurizio
    Watson, Charles
    Nuyts, Johan
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2012, 31 (12) : 2224 - 2233
  • [48] The mobile PET insert for simultaneous PET/MRI imaging
    Zielinski, M.
    Glowacz, B.
    Alfs, D.
    Bednarski, T.
    Bialas, P.
    Czerwinski, E.
    Gajos, A.
    Gorgol, M.
    Jasinska, B.
    Kaminska, D.
    Kaplon, L.
    Korcyl, G.
    Kowalski, P.
    Kozik, T.
    Krzemien, W.
    Kubicz, E.
    Mohammed, M.
    Pawlik-Niedzwiecka, M.
    Niedzwiecki, S.
    Palka, M.
    Raczynski, L.
    Rudy, Z.
    Rundel, O.
    Sharma, N. G.
    Silarski, M.
    Slomski, A.
    Strzelecki, A.
    Wieczorek, A.
    Wislicki, W.
    Zgardzinska, B.
    Moskal, P.
    RADIOTHERAPY AND ONCOLOGY, 2016, 118 : S117 - S118
  • [49] Markerless motion tracking and correction for PET, MRI, and simultaneous PET/MRI
    Slipsager, Jakob M.
    Ellegaard, Andreas H.
    Glimberg, Stefan L.
    Paulsen, Rasmus R.
    Tisdall, M. Dylan
    Wighton, Paul
    van der Kouwe, Andre
    Marner, Lisbeth
    Henriksen, Otto M.
    Law, Ian
    Olesen, Oline V.
    PLOS ONE, 2019, 14 (04):
  • [50] Workflow in Simultaneous PET/MRI
    Barbosa, Felipe de Galiza
    von Schulthess, Gustav
    Veit-Haibach, Patrick
    SEMINARS IN NUCLEAR MEDICINE, 2015, 45 (04) : 332 - 344