Improvements in PET Image Quality in Time of Flight (TOF) Simultaneous PET/MRI

被引:27
|
作者
Minamimoto, Ryogo [1 ,2 ]
Levin, Craig [2 ]
Jamali, Mehran [1 ,2 ]
Holley, Dawn [3 ]
Barkhodari, Amir [1 ]
Zaharchuk, Greg [3 ]
Iagaru, Andrei [1 ]
机构
[1] Stanford Univ, Div Nucl Med & Mol Imaging, Dept Radiol, 300 Pasteur Dr,H2200, Stanford, CA 94305 USA
[2] Stanford Univ, Mol Imaging Program Stanford, Dept Radiol, Stanford, CA 94305 USA
[3] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
关键词
PET/MRI; PET/CT; Time of flight; Artifact; Image quality; EMISSION TOMOGRAPHY/COMPUTED TOMOGRAPHY; ATTENUATION CORRECTION; RESPIRATORY MOTION; CLINICAL-EXPERIENCE; DENTAL IMPLANTS; ARTIFACTS; ATLAS; MRI; REGISTRATION; GENERATION;
D O I
10.1007/s11307-016-0939-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
An integrated positron emission tomography (PET)/magnetic resonance imaging (MRI) scanner with time of flight (TOF) technology is now available for clinical use. The aim of this study is to evaluate the potential of TOF PET in PET/MRI to reduce artifacts in PET images when compared to non-TOF PET/MRI, TOF PET/X-ray computed tomography (CT), and non-TOF PET/CT. All patients underwent a single 2-deoxy-2-[F-18]fluoro-d-glucose ([F-18]FDG) injection, followed first by PET/CT, and subsequently by PET/MRI. PET/CT exams were requested as standard-of-care for oncological indications. Using the PET acquisitions datasets, 4 series of images (TOF PET/CT, non-TOF PET/CT, TOF PET/MRI, and non-TOF PET/MRI) were reconstructed. These image series were visually evaluated for: (1) dental metal artifacts, (2) breathing artifacts, and (3) pelvic artifacts due to scatter correction errors from high bladder [F-18]FDG concentration. PET image quality was assessed by a 3-point scale (1-clinically significant artifact, 2-non clinically significant artifact, and 3-no artifact). Twenty-five patients (mean +/- SD age: 56 +/- 13 years old; female: 10, male: 15) were enrolled. TOF PET/MRI, non-TOF PET/MRI, TOF PET/CT, and non-TOF PET/CT scores 2.8, 2.5, 2.4, and 2.3, respectively for the presence of dental artifacts, 2.8, 2.5, 2.2, and 1.9, respectively, for the presence of breathing artifacts, and 2.7, 1.7, 2.0, and 1.3, respectively, for the presence of pelvic artifacts TOF PET/MRI images showed the highest image quality scores among the 4 datasets of PET images. The superior timing resolution and resulting TOF capability of the new PET/MRI scanner improved PET image quality in this cohort by reducing artifacts compared to non-TOF PET/MRI, TOF PET/CT, and non-TOF PET/CT.
引用
收藏
页码:776 / 781
页数:6
相关论文
共 50 条
  • [31] Simultaneous reconstruction of the activity image and registration of the CT image in TOF-PET
    Rezaei, Ahmadreza
    Michel, Christian
    Casey, Michael E.
    Nuyts, Johan
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (04): : 1852 - 1874
  • [32] The impact of reconstruction algorithms and time of flight information on PET/CT image quality
    Suljic, Alen
    Tomse, Petra
    Jensterle, Luka
    Skrk, Damijan
    RADIOLOGY AND ONCOLOGY, 2015, 49 (03) : 227 - 233
  • [33] Minimisation of Acquisition Time in a TOF PET/CT Scanner Without Compromising Image Quality
    Oliveira, J.
    Parafita, R.
    Branco, S.
    VIPIMAGE 2017, 2018, 27 : 27 - 42
  • [34] Simultaneous emission and transmission imaging for PET-MRI using time-of-flight information
    Mollet, Pieter
    Keereman, Vincent
    Vandenberghe, Stefaan
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [35] Estimating image quality for future generations of TOF PET scanners
    Conti, Maurizio
    Eriksson, Lars
    Westerwoudt, Victor
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 2407 - 2414
  • [36] Estimating Image Quality for Future Generations of TOF PET Scanners
    Conti, Maurizio
    Eriksson, Lars
    Westerwoudt, Victor
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2013, 60 (01) : 87 - 94
  • [37] Investigation of acquisition time for harmonization of image quality between PET/CT and PET/MRI systems: A phantom study
    Yoon, Seok Hwan
    Park, Chan Rok
    OPTIK, 2021, 244
  • [38] Time-of-flight precision and PET image accuracy
    Kolthammer, Jeffrey A.
    Tang, Jing
    Perkins, Amy E.
    Muzic, Raymond F., Jr.
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 3657 - 3660
  • [39] Accelerated time-of-flight (TOF) PET image reconstruction using TOF bin subsetization and TOF weighting matrix pre-computation
    Mehranian, Abolfazl
    Kotasidis, Fotis
    Zaidi, Habib
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (03): : 1309 - 1331
  • [40] Simultaneous reconstruction of attenuation and activity in ToF PET/MRI with additional transmission data
    Ester D’Hoe
    Pieter Mollet
    Ekaterina Mikhaylova
    Michel Defrise
    Stefaan Vandenberghe
    EJNMMI Physics, 2 (Suppl 1)