Optical coherence tomography versus ultrasound biomicroscopy of conjunctival and eyelid lesions

被引:0
|
作者
Buchwald, J [1 ]
Müller, A [1 ]
Kampmeier, J [1 ]
Lang, GK [1 ]
机构
[1] Univ Augenklin Ulm, D-89075 Ulm, Germany
关键词
ultrasound biomicroscopy; optical coherence tomography; eyelid tumour; eyelid cyst; chalazion; basal cell carcinoma; conjunctival tumour; conjunctive compound naevus; pterygium;
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: The value of ultrasound biomicroscopy in the diagnosis of conjunctival and eyelid lesions is still unknown. Method: For the examination of conjunctival and eyelid lesions, we used an anterior segment OCT (4optics, Lubeck) and an ultrasound biomicroscope (Humphrey, Zeiss, Oberkochen) with high frequency transducer (30 MHz). Included in this study were all patients with conjunctival and eyelid lesions, which were consecutively operated on between December 2002 and January 2003. Histological examination of the excised tissue was performed. Results: 38 tumours of 35 patients, aged 8-93 years, were examined. 13 tumours were conjunctival lesions and 25 tumours were eyelid lesions. Histological examination displayed the presence of a pterygium (8/38), a seborrhoic keratosis (7/38), a cyst of the eyelid (5/38), a basal cell carcinoma of the eyelid (4/38), a compound naevus of the conjunctiva (4/38), a chalazion (3/38), a primary acquired melanosis (1/38), an actinic keratosis (1/38), a naevus (1/38), a cavernous haemangioma (1/38), a melanoma in situ (1/38), a foreign body (1/38), and an epidermoid cyst (1/38). Using both ultrasound biomicroscopy and optical coherence tomography (OCT) we were able to demonstrate a cystic tumour in the five patients (13%) with a cyst of the eyelid. With OCT and with ultrasoundbiomicroscopy in all patients with pterygium a slit was found and in patients with compound naevus very small cystic structures were seen, but with OCT the imaging was more reliable. In patients with solid tumours the definite diagnosis could not be differentiated by ultrasound biomicroscopy or OCT alone. Using OCT, assessment of the margins of the tumours (particularly in depth) was impossible or uncertain. Conclusion: Compared to ultrasound biomicroscopy OCT is able to show very small cystic structures more distinctly. For assessing the margins of the tumour ultrasound biornicroscopy is the better tool.
引用
收藏
页码:822 / 829
页数:8
相关论文
共 50 条
  • [21] Ultrasound biomicroscopy in eyelid lesions - a clinical study on 30 patients
    Buchwald, HJ
    Spraul, CW
    Kampmeier, J
    Lang, GK
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2002, 219 (03) : 95 - 100
  • [22] Comparison of optical coherence tomography and ultrasound biomicroscopy for detection of narrow anterior chamber angles
    Radhakrishnan, S
    Goldsmith, J
    Huang, D
    Westphal, V
    Dueker, DK
    Rollins, AM
    Izatt, JA
    Smith, SD
    ARCHIVES OF OPHTHALMOLOGY, 2005, 123 (08) : 1053 - 1059
  • [23] Comparison of Stratus Optical Coherence Tomography and Ultrasound Biomicroscopy for Measurement of the Central Corneal Thickness
    Turk, Adem
    Erdol, Hidayet
    Karaguzel, Hande
    Akyol, Nurettin
    TURKIYE KLINIKLERI TIP BILIMLERI DERGISI, 2010, 30 (03): : 962 - 969
  • [24] Anterior Segment Optical Coherence Tomography and Ultrasound Biomicroscopy in the Imaging of Anterior Segment Tumors
    Pavlin, Charles J.
    Vasquez, Luz Maria
    Lee, Richard
    Simpson, E. Rand
    Ahmed, Iqbal Ike K.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2009, 147 (02) : 214 - 219
  • [25] Imaging implanted keratoprostheses with anterior-segment optical coherence tomography and ultrasound biomicroscopy
    Garcia, Julian P. S., Jr.
    de la Cruz, Jose
    Rosen, Richard B.
    Buxton, Douglas E.
    CORNEA, 2008, 27 (02) : 180 - 188
  • [26] Comparison of anterior segment optical coherence tomography and ultrasound biomicroscopy for assessment of the anterior segment
    Dada, Tanuj
    Sihota, Ramanjit
    Gadia, Ritu
    Aggarwal, Anand
    Mandal, Subrata
    Gupta, Viney
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (05): : 837 - 840
  • [27] Accuracy of Optical Coherence Tomography versus Ultrasound in pachymetry
    Vonor, K.
    Amedome, K. M.
    Santos, M. A. K.
    Koko, R. A. Kuaovi
    Maneh, N.
    Dzidzinyo, K.
    Ayena, K. D.
    Banla, M.
    Balo, K. P.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2021, 44 (07): : 1047 - 1051
  • [28] Correlation of anterior segment optical coherence tomography and ultrasound biomicroscopy in congenital corneal opacity
    Yangzes, Sonam
    Kaushik, Sushmita
    Malhotra, Chintan
    Thakur, Anchal
    Gupta, Amit
    Jain, Arun Kumar
    Jinagal, Jitender
    Pandav, Surinder Singh
    JOURNAL OF AAPOS, 2024, 28 (02):
  • [29] Intravascular Ultrasound Versus Optical Coherence Tomography Guidance
    不详
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 62 (17) : S32 - S40
  • [30] Optical coherence tomography—versus intravascular ultrasound-guided stent expansion in calcified lesions
    Kazumasa Kurogi
    Masanobu Ishii
    Sou Ikebe
    Ryota Kaichi
    Takayuki Mori
    Soichi Komaki
    Nobuyasu Yamamoto
    Kenshi Yamanaga
    Yuichiro Arima
    Eiichiro Yamamoto
    Koichi Kaikita
    Kenichi Matsushita
    Kenichi Tsujita
    Cardiovascular Intervention and Therapeutics, 2022, 37 : 312 - 323