Accuracy of Optical Coherence Tomography versus Ultrasound in pachymetry

被引:0
|
作者
Vonor, K. [1 ,4 ]
Amedome, K. M. [2 ,4 ]
Santos, M. A. K. [4 ]
Koko, R. A. Kuaovi [3 ]
Maneh, N. [4 ]
Dzidzinyo, K. [4 ]
Ayena, K. D. [4 ]
Banla, M. [4 ]
Balo, K. P. [4 ]
机构
[1] Univ Kara, Serv Ophtalm, CHR Kara Tomde, Fac Sci Sante, BP 13648, Lome, Togo
[2] CHU Kara, Serv Ophtalmol, Lome, Togo
[3] Cabinet Ophtalmol AFIA, Rabat, Morocco
[4] Univ Lome, Fac Sci Sante, Dept Ophtalmol, Lome, Togo
来源
JOURNAL FRANCAIS D OPHTALMOLOGIE | 2021年 / 44卷 / 07期
关键词
Pachymetry; Ultrasound; OCT; Reliability; Blacks; CENTRAL CORNEAL THICKNESS; INTRAOCULAR-PRESSURE; CAUCASIANS; HISPANICS; GLAUCOMA;
D O I
10.1016/j.jfo.2020.08.037
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. - Measuring the central corneal thickness is an important step in the diagnosis and monitoring of glaucoma. Ultrasound pachymetry was the gold standard before the advent of OCT The purpose of this study is to assess the reliability of OCT pachymetry compared to ultrasound pachymetry in black patients. Patients and methods. - Pachymetry was performed as part of a glaucoma work-up. Ultrasonic pachymetry was measured using the Alcon Ocuscan by the same operator and OCT pachymetry using the Topcon 2000 OCT. The Student's t-test was used to compare means with statistical significance of 5%. The Pearson's correlation coefficient (r(2)) was used to measure correlations. Results. - One-hundred thirty-five right eyes and 135 left eyes, corresponding to 270 eyes of 135 patients, were examined. There was a female predominance (59 men/76 women), with a gender ratio of 0.78. The mean age was 42.3 +/- 17.3 [8-86] years. In the right eye, the mean OCT pachymetry was 522.4 +/- 36.8 mu. versus 528.2 +/- 37.9 mu for ultrasonic pachymetry (P= 1.00). In the left eye, the mean OCT pachymetry was 522.0 +/- 33.8 mu versus 524.9 +/- 42.5 mu for ultrasonic pachymetry (P= 1.00). The overall mean OCT pachymetry was 522.2 +/- 35.2 mu versus 526.5 +/- 40.2 mu, with a non-significant difference (P= 1.00). There was a strong correlation between ultrasonic pachymetry and OCT pachymetry (r(2) =0.83; P < 0.05). On the other hand, there was a very tow correlation between pachymetry and age (r(2) =0.09; P< 0.05). Pachymetry decreased by 5 mu per 10 years, corresponding to corneal thinning of 0.5 mu per year. Conclusion. - OCT pachymetry can be a reliable alternative to ultrasound pachymetry and could be performed at the same time as the OCT for glaucoma assessment. (C) 2021 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:1047 / 1051
页数:5
相关论文
共 50 条
  • [1] Comparison of Topcon Optical Coherence Tomography and Ultrasound Pachymetry
    Northey, Luke Cameron
    Gifford, Paul
    Boneham, Gavin C.
    OPTOMETRY AND VISION SCIENCE, 2012, 89 (12) : 1708 - 1714
  • [2] Accuracy of optical coherence tomography (OCT) in pachymetry for glaucoma patients
    Marcelo Ayala
    Robert Strandås
    BMC Ophthalmology, 15
  • [3] Accuracy of optical coherence tomography (OCT) in pachymetry for glaucoma patients
    Ayala, Marcelo
    Strandas, Robert
    BMC OPHTHALMOLOGY, 2015, 15
  • [4] Accuracy of optical coherence tomography (OCT) pachymetry in glaucoma patients
    Strandas, Robert
    Ayala, Marcelo
    ACTA OPHTHALMOLOGICA, 2014, 92 : 3 - 3
  • [5] Corneal Thickness in Keratoconus Comparing Optical, Ultrasound, and Optical Coherence Tomography Pachymetry
    Dutta, Debarun
    Rao, Harsha L.
    Addepalli, Uday K.
    Vaddavalli, Pravin K.
    OPHTHALMOLOGY, 2013, 120 (03) : 457 - 463
  • [6] Correspondence: Comparison of Central Corneal Thickness using Anterior Segment Optical Coherence Tomography Versus Ultrasound Pachymetry
    De Bernardo, Maddalena
    Rosa, Nicola
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2018, 12 (03) : NL01 - NL01
  • [7] Comparison of Ultrasound Pachymetry Versus Optical Coherence Tomography in Precut Descemet's Stripping Automated Endothelial Keratoplasty
    Gordon, Abigail
    Golla, Abhinav
    Weikert, Mitchell
    Wang, Li
    Khandelwal, Sumitra
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [8] Intravascular ultrasound versus optical coherence tomography
    Hajar, Rachel
    HEART VIEWS, 2019, 20 (01): : 35 - 36
  • [9] Comparison between central corneal thickness measurements by ultrasound pachymetry and optical coherence tomography
    Leung, Dexter Y. L.
    Lam, Douglas K. T.
    Yeung, Barry Y. M.
    Lam, Dennis S. C.
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2006, 34 (08): : 751 - 754
  • [10] Anterior Segment Optical Coherence Tomography Versus Ultrasound Pachymetry to Measure Corneal Thickness in Endothelial Keratoplasty Donor Corneas
    Fante, Ryan J.
    Shtein, Roni M.
    Titus, Michael S.
    Woodward, Maria A.
    CORNEA, 2013, 32 (05) : E79 - E82