Accuracy of Optical Coherence Tomography versus Ultrasound in pachymetry

被引:0
|
作者
Vonor, K. [1 ,4 ]
Amedome, K. M. [2 ,4 ]
Santos, M. A. K. [4 ]
Koko, R. A. Kuaovi [3 ]
Maneh, N. [4 ]
Dzidzinyo, K. [4 ]
Ayena, K. D. [4 ]
Banla, M. [4 ]
Balo, K. P. [4 ]
机构
[1] Univ Kara, Serv Ophtalm, CHR Kara Tomde, Fac Sci Sante, BP 13648, Lome, Togo
[2] CHU Kara, Serv Ophtalmol, Lome, Togo
[3] Cabinet Ophtalmol AFIA, Rabat, Morocco
[4] Univ Lome, Fac Sci Sante, Dept Ophtalmol, Lome, Togo
来源
JOURNAL FRANCAIS D OPHTALMOLOGIE | 2021年 / 44卷 / 07期
关键词
Pachymetry; Ultrasound; OCT; Reliability; Blacks; CENTRAL CORNEAL THICKNESS; INTRAOCULAR-PRESSURE; CAUCASIANS; HISPANICS; GLAUCOMA;
D O I
10.1016/j.jfo.2020.08.037
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. - Measuring the central corneal thickness is an important step in the diagnosis and monitoring of glaucoma. Ultrasound pachymetry was the gold standard before the advent of OCT The purpose of this study is to assess the reliability of OCT pachymetry compared to ultrasound pachymetry in black patients. Patients and methods. - Pachymetry was performed as part of a glaucoma work-up. Ultrasonic pachymetry was measured using the Alcon Ocuscan by the same operator and OCT pachymetry using the Topcon 2000 OCT. The Student's t-test was used to compare means with statistical significance of 5%. The Pearson's correlation coefficient (r(2)) was used to measure correlations. Results. - One-hundred thirty-five right eyes and 135 left eyes, corresponding to 270 eyes of 135 patients, were examined. There was a female predominance (59 men/76 women), with a gender ratio of 0.78. The mean age was 42.3 +/- 17.3 [8-86] years. In the right eye, the mean OCT pachymetry was 522.4 +/- 36.8 mu. versus 528.2 +/- 37.9 mu for ultrasonic pachymetry (P= 1.00). In the left eye, the mean OCT pachymetry was 522.0 +/- 33.8 mu versus 524.9 +/- 42.5 mu for ultrasonic pachymetry (P= 1.00). The overall mean OCT pachymetry was 522.2 +/- 35.2 mu versus 526.5 +/- 40.2 mu, with a non-significant difference (P= 1.00). There was a strong correlation between ultrasonic pachymetry and OCT pachymetry (r(2) =0.83; P < 0.05). On the other hand, there was a very tow correlation between pachymetry and age (r(2) =0.09; P< 0.05). Pachymetry decreased by 5 mu per 10 years, corresponding to corneal thinning of 0.5 mu per year. Conclusion. - OCT pachymetry can be a reliable alternative to ultrasound pachymetry and could be performed at the same time as the OCT for glaucoma assessment. (C) 2021 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:1047 / 1051
页数:5
相关论文
共 50 条
  • [41] Noncontact corneal pachymetry with slit lamp-adapted optical coherence tomography
    Wirbelauer, C
    Scholz, C
    Hoerauf, H
    Pham, DT
    Laqua, H
    Birngruber, R
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2002, 133 (04) : 444 - 450
  • [42] Central corneal thickness measurements with optical coherence tomography and ultrasound pachymetry in healthy subjects and in patients after photorefractive keratectomy
    Schneider, Miklos
    Borgulya, Gabor
    Seres, Andras
    Nagy, Zoltan Z.
    Nemeth, Janos
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2009, 19 (02) : 180 - 187
  • [43] Comparative Study of Central Corneal Thickness Using Fourier-Domain Optical Coherence Tomography Versus Ultrasound Pachymetry in Primary Open-Angle Glaucoma
    Garcia-Medina, Jose J.
    Garcia-Medina, Manuel
    Garcia-Maturana, Carlos
    Zanon-Moreno, Vicente
    Pons-Vazquez, Sheila
    Pinazo-Duran, Maria D.
    CORNEA, 2013, 32 (01) : 9 - 13
  • [44] Intravascular ultrasound versus optical coherence tomography: Calibrating the use of intracoronary imaging
    Ribeiro, Jose
    Pires-Morais, Gustavo
    REVISTA PORTUGUESA DE CARDIOLOGIA, 2023, 42 (07) : 641 - 642
  • [45] Accuracy of optical navigation systems for automatic head surgery: optical tracking versus optical coherence tomography
    Diaz, Jesus Diaz
    Riva, Mauro H.
    Majdani, Omid
    Ortmaier, Tobias
    PHOTONIC THERAPEUTICS AND DIAGNOSTICS X, 2014, 8926
  • [46] Relation between optical coherence tomography and optical pachymetry measurements of corneal swelling induced by hypoxia
    Wang, JH
    Fonn, D
    Simpson, TL
    Jones, L
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2002, 134 (01) : 93 - 98
  • [47] Correlational study of central corneal thickness measurements on Hong Kong Chinese using optical coherence tomography, Orbscan and ultrasound pachymetry
    Wong, ACM
    Wong, CC
    Yuen, NSY
    Hui, SP
    EYE, 2002, 16 (06) : 715 - 721
  • [48] Correlational study of central corneal thickness measurements on Hong Kong Chinese using optical coherence tomography, Orbscan and ultrasound pachymetry
    A C-M Wong
    C-C Wong
    N S-Y Yuen
    S-P Hui
    Eye, 2002, 16 : 715 - 721
  • [49] Comparison of central corneal thickness measurements by ultrasound pachymetry, Orbscan, and third generation optical coherence tomography (OCT3)
    Fishman, GR
    Pons, M
    Makornwattana, M
    Seedor, J
    Liebmann, J
    Ritch, R
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U5 - U5
  • [50] Central Corneal Thickness Measurements With Fourier-Domain Optical Coherence Tomography Versus Ultrasonic Pachymetry and Rotating Scheimpflug Camera
    Ishibazawa, Akihiro
    Igarashi, Sho
    Hanada, Kazuomi
    Nagaoka, Taiji
    Ishiko, Satoshi
    Ito, Haruna
    Yoshida, Akitoshi
    CORNEA, 2011, 30 (06) : 615 - 619