Imaging implanted keratoprostheses with anterior-segment optical coherence tomography and ultrasound biomicroscopy

被引:34
|
作者
Garcia, Julian P. S., Jr. [1 ,2 ]
de la Cruz, Jose [1 ,3 ]
Rosen, Richard B. [1 ,2 ]
Buxton, Douglas E. [1 ,2 ]
机构
[1] New York Eye & Ear Infirm, Retina Ctr, New York, NY 10003 USA
[2] New York Med Coll, Valhalla, NY 10595 USA
[3] Illinois Eye & Ear Infirm, Chicago, IL USA
关键词
anterior-segment optical coherence tomography; coronal optical coherence tomography; optical coherence tomography; keratoprosthesis; ultrasound biomicroscopy;
D O I
10.1097/ICO.0b013e318159bc7d
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To describe the anterior ocular segment findings of eyes with implanted Boston type 1 keratoprostheses (KPro) in vivo by using anterior-segment optical coherence tomography (AS-OCT) and ultrasound biomicroscopy (UBM). Methods: A retrospective, comparative study was made of patients with implanted KPros who were examined with AS-OCT (AC Cornea OCT) and UBM (OTI Scan 35-50MHz Ultrasound). Results: One pseudophakic and 1 aphakic eye were included in the study. Cross-sectional AS-OCT adequately imaged the components of the KPro (front plate with stem, back plate, and titanium ring), the corneal graft, and host cornea. The angles could be seen as open, filled with debris, or closed. Coronal AS-OCT showed en face views of each KPro part. Retrokeratoprosthetic membranes were depicted to be thick opacities covering the rear optical surface of the stem. UBM, on the other hand, imaged the KPro front plate as a muffin-shaped space at the apical center, with the corneal graft appearing wispy and the host cornea grainy. The back plate, titanium ring, and angles could not be resolved. Glaucoma tubes and posterior-chamber intraocular lens (PCIOL) haptics were imaged below the iris plane. Conclusions: Cross-sectional AS-OCT adequately imaged the components of the assembled KPro in vivo, as well as its interaction with surrounding anterior-segment structures. It allowed visualization of the anterior chamber, iris, and angle, essential in the postoperative care of these patients. Coronal AS-OCT showed graphic en face images of the KPro device and suspected retrokeratoprosthetic membranes. UBM, on the other hand, adequately imaged glaucoma tube shunts and PCIOL haptics beneath the iris plane.
引用
收藏
页码:180 / 188
页数:9
相关论文
共 50 条
  • [1] Anterior segment imaging: ultrasound biomicroscopy and anterior segment optical coherence tomography
    Nolan, Winifred
    CURRENT OPINION IN OPHTHALMOLOGY, 2008, 19 (02) : 115 - 121
  • [2] Anterior Segment Optical Coherence Tomography and Ultrasound Biomicroscopy in the Imaging of Anterior Segment Tumors
    Pavlin, Charles J.
    Vasquez, Luz Maria
    Lee, Richard
    Simpson, E. Rand
    Ahmed, Iqbal Ike K.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2009, 147 (02) : 214 - 219
  • [3] Anterior Segment Imaging: Optical Coherence Tomography Versus Ultrasound Biomicroscopy
    Garcia, Julian P. S., Jr.
    Rosen, Richard B.
    OPHTHALMIC SURGERY LASERS & IMAGING, 2008, 39 (06) : 476 - 484
  • [4] Imaging of Anterior Segment Tumours: A Comparison of Ultrasound Biomicroscopy Versus Anterior Segment Optical Coherence Tomography
    Kottaridou, Eleni
    Hatoum, Adam
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (01)
  • [5] Comparison of Ultrasound Biomicroscopy versus Anterior Segment Optical Coherence Tomography for Imaging of Anterior Segment Tumors
    Bianciotto, C. G.
    Romanelli, M.
    Guzman, M.
    Mazzuca, D.
    Green, R.
    Shields, C. L.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [6] Comparison of anterior segment optical coherence tomography and ultrasound biomicroscopy for assessment of the anterior segment
    Dada, Tanuj
    Sihota, Ramanjit
    Gadia, Ritu
    Aggarwal, Anand
    Mandal, Subrata
    Gupta, Viney
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (05): : 837 - 840
  • [7] Imaging the Canaliculops With Ultrasound Biomicroscopy and Anterior Segment Ocular Coherence Tomography
    Singh, Swati
    Ali, Mohammad Javed
    Peguda, Hari Kumar
    Naik, Milind N.
    OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 2017, 33 (06): : E143 - E144
  • [8] Iridotrabecular Contact Evaluated With Anterior-Segment Swept-Source Optical Coherence Tomography and Ultrasound Biomicroscopy in Narrow Angle Eyes
    Mishima, K.
    Tomidokoro, A.
    Suramethakul, P.
    Mataki, N.
    Kurita, N.
    Araie, M.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [9] Assessment of Anterior Segment Tumors with Ultrasound Biomicroscopy versus Anterior Segment Optical Coherence Tomography in 200 Cases
    Bianciotto, Carlos
    Shields, Carol L.
    Guzman, Juan M.
    Romanelli-Gobbi, Massi
    Mazzuca, Douglas, Jr.
    Green, W. Ross
    Shields, Jerry A.
    OPHTHALMOLOGY, 2011, 118 (07) : 1297 - 1302
  • [10] Comparison of Anterior Segment Time Domain Optical Coherence Tomography and High Frequency Ultrasound Biomicroscopy for Anterior Segment
    Cardascia, N.
    Guerriero, S.
    Ferreri, P.
    Furino, C.
    Boscia, F.
    Vetrugno, M.