Imaging implanted keratoprostheses with anterior-segment optical coherence tomography and ultrasound biomicroscopy

被引:34
|
作者
Garcia, Julian P. S., Jr. [1 ,2 ]
de la Cruz, Jose [1 ,3 ]
Rosen, Richard B. [1 ,2 ]
Buxton, Douglas E. [1 ,2 ]
机构
[1] New York Eye & Ear Infirm, Retina Ctr, New York, NY 10003 USA
[2] New York Med Coll, Valhalla, NY 10595 USA
[3] Illinois Eye & Ear Infirm, Chicago, IL USA
关键词
anterior-segment optical coherence tomography; coronal optical coherence tomography; optical coherence tomography; keratoprosthesis; ultrasound biomicroscopy;
D O I
10.1097/ICO.0b013e318159bc7d
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To describe the anterior ocular segment findings of eyes with implanted Boston type 1 keratoprostheses (KPro) in vivo by using anterior-segment optical coherence tomography (AS-OCT) and ultrasound biomicroscopy (UBM). Methods: A retrospective, comparative study was made of patients with implanted KPros who were examined with AS-OCT (AC Cornea OCT) and UBM (OTI Scan 35-50MHz Ultrasound). Results: One pseudophakic and 1 aphakic eye were included in the study. Cross-sectional AS-OCT adequately imaged the components of the KPro (front plate with stem, back plate, and titanium ring), the corneal graft, and host cornea. The angles could be seen as open, filled with debris, or closed. Coronal AS-OCT showed en face views of each KPro part. Retrokeratoprosthetic membranes were depicted to be thick opacities covering the rear optical surface of the stem. UBM, on the other hand, imaged the KPro front plate as a muffin-shaped space at the apical center, with the corneal graft appearing wispy and the host cornea grainy. The back plate, titanium ring, and angles could not be resolved. Glaucoma tubes and posterior-chamber intraocular lens (PCIOL) haptics were imaged below the iris plane. Conclusions: Cross-sectional AS-OCT adequately imaged the components of the assembled KPro in vivo, as well as its interaction with surrounding anterior-segment structures. It allowed visualization of the anterior chamber, iris, and angle, essential in the postoperative care of these patients. Coronal AS-OCT showed graphic en face images of the KPro device and suspected retrokeratoprosthetic membranes. UBM, on the other hand, adequately imaged glaucoma tube shunts and PCIOL haptics beneath the iris plane.
引用
收藏
页码:180 / 188
页数:9
相关论文
共 50 条
  • [41] Association of Narrow Angles With Anterior Chamber Area and Volume Measured With Anterior-Segment Optical Coherence Tomography
    Wu, Ren-Yi
    Nongpiur, Monisha E.
    He, Ming-Guang
    Sakata, Lisandro M.
    Friedman, David S.
    Chan, Yiong-Huak
    Lavanya, Raghavan
    Wong, Tien-Yin
    Aung, Tin
    ARCHIVES OF OPHTHALMOLOGY, 2011, 129 (05) : 569 - 574
  • [42] Pigmented Iris Lesion on Anterior-Segment Swept-Source Optical Coherence Tomography
    Vaidya, Sarangdev
    Yaghy, Antonio
    Shields, Carol L.
    JAMA OPHTHALMOLOGY, 2021, 139 (01)
  • [43] Lymphangiectasia Hemorrhagica Conjunctivae Regression with Bleomycin Sclerotherapy on Anterior-Segment Optical Coherence Tomography
    Tripathy, Devjyoti
    JAMA OPHTHALMOLOGY, 2023, 141 (10)
  • [44] Evaluation of filtration bleb by multi-contrast anterior-segment optical coherence tomography
    Kasaragod, Deepa
    Makita, Shuichi
    Ueno, Yuta
    Hoshi, Sujin
    Fukuda, Shinichi
    Oshika, Tetsuro
    Yasuno, Yoshiaki
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [45] Patency of small laser iridotomy evaluated using anterior-segment optical coherence tomography
    Nakabayashi, Seigo
    Kawai, Motofumi
    Yamaguchi, Toru
    Yoshida, Akitoshi
    CLINICAL OPHTHALMOLOGY, 2014, 8 : 595 - 597
  • [46] Comparing anterior segment optical coherence tomography and ultrasound biomicroscopy with histopathology in measurement of corneal and bulbar conjunctival tumors depth
    Lauwers, N.
    Janssens, K.
    Mertens, M.
    Mathysen, D.
    De Keizer, R. J. W.
    De Groot, V.
    ACTA OPHTHALMOLOGICA, 2017, 95
  • [47] Comparison of anterior section parameters using anterior segment optical coherence tomography and ultrasound biomicroscopy in myopic patients after ICL implantation
    Zhang, Jing
    Luo, Hui-Hui
    Zhuang, Jing
    Yu, Ke-Ming
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2016, 9 (01) : 58 - 62
  • [48] Comparison of anterior section parameters using anterior segment optical coherence tomography and ultrasound biomicroscopy in myopic patients after ICL implantation
    Jing Zhang
    Hui-Hui Luo
    Jing Zhuang
    Ke-Ming Yu
    International Journal of Ophthalmology, 2016, (01) : 58 - 62
  • [49] Optical Biopsy Using Anterior-Segment Optical Coherence Tomography in Ocular Surface Tumors: The Game Changer
    Ucakhan, Omur O.
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2024, 50 (06): : 241 - 242
  • [50] Evaluation of corneal epithelial thickness in glaucomatous patients using anterior-segment optical coherence tomography
    Montorio, Daniela
    Cennamo, Gilda
    Breve, Maria A.
    Fiore, Ugo
    Reibaldi, Michele
    Morra, Vincenzo Brescia
    Cennamo, Giovanni
    JOURNAL OF BIOPHOTONICS, 2020, 13 (01)