摘要
Background: Our aim was to analyze the effects of set-up errors on dose distribution in radiotherapy treatment for lung cancer by using kilovoltage cone-beam CT (CBCT). Materials and Methods: In this study, we used a Varian IX linear accelerator system to perform CBCT scans of 30 lung cancer patients before radiotherapy. Subsequently, the image was matched with the planned CT, and the left and right (LR), top and bottom (SI), and front and back (AP) directions were set incorrectly. And in the CMS planning system, the center of the plan has been moved to the center of the actual scan. Finally, the dose distribution before the bed-moving is simulated. We want to explore the impact of the planned target volume setting error (PTV), the total tumor volume (GTV), and radiation of normal tissues. Results: The set-up errors of the LR, SI and AP directions were (-0.20 +/- 2.84), (-1.09 +/- 5.40), and (-2.61 +/- 2.08) mm, respectively. The 5mm error accounted for 97.8%, 73% and 92.6% in the three directions. Statistically significant differences were found in the distribution of 95% PTV dose, the average dose of PTV, 95% GTV dose and the average dose of GTV without bed-moving, compared with the original plan. Conclusions: In clinical lung cancer radiotherapy, the commonly used setting error is usually less than 5mm, most of which are along the AP direction. In this study, we found that the setting error is related to the patient's inherent characteristics and can significantly change the radiation treatment dose in the target area.
引用
收藏
页码:515 / 520
页数:6
相关论文
共 50 条
  • [21] Accuracy of set-up of thoracic radiotherapy: prospective analysis of 24 patients treated with radiotherapy for lung cancer
    Essapen, S
    Knowles, C
    Norman, A
    Tait, D
    BRITISH JOURNAL OF RADIOLOGY, 2002, 75 (890): : 162 - 169
  • [22] Evaluation of the Treatment Field Deviations in Different Set-up Positions During Thoracic Radiotherapy in Lung Cancer Patients
    Guzeloz, Zeliha
    Ellidokuz, Hulya
    Yildirim, Ayse
    Yigitbasi, Levent
    Cetingoz, Riza
    TURK ONKOLOJI DERGISI-TURKISH JOURNAL OF ONCOLOGY, 2022, 37 (04): : 394 - 402
  • [23] Set-up errors in prostate cancer radiotherapy based on cone-beam computed tomography.
    Trignani, M.
    Caponigro, G.
    Di Biase, M.
    Bagala, P.
    Falco, M. D.
    Vinciguerra, A.
    Augurio, A.
    Di Tommaso, M.
    Caravatta, L.
    Genovesi, D.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S723 - S723
  • [25] Analysis of interfraction set-up errors during radiotherapy for head and neck cancers
    Kobayashi, H.
    Saito, Y.
    Hibino, Y.
    Egami, K.
    Ito, M.
    Koizumi, M.
    Katada, K.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S297 - S297
  • [26] Intraoral stent reduces set-up errors in image guided radiotherapy for head and neck cancer patients
    Tarutani, K.
    Doi, H.
    Tanooka, M.
    Ishida, T.
    Kosaka, K.
    Ichimiya, K.
    Moridera, K.
    Kitajima, K.
    Yasuhiro, T.
    Fujiwara, M.
    Kishimoto, H.
    Kamikonya, N.
    EUROPEAN JOURNAL OF CANCER, 2017, 72 : S108 - S108
  • [27] Radiotherapy technicians inter-observer variability on evaluating set-up errors
    Perez Sanchez, JM.
    Costal, C.
    Pelaez, S.
    Cortes, A.
    Davila, E.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S271 - S271
  • [28] Comparison of immobilisation, imaging and set-up errors during head and neck radiotherapy
    Hay, L.
    Devlin, L.
    Duffton, A.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S2044 - S2045
  • [29] SPECIAL SET-UP AND TREATMENT TECHNIQUES FOR RADIOTHERAPY OF PEDIATRIC MALIGNANCIES
    MARTINEZ, A
    DONALDSON, SS
    BAGSHAW, MA
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1977, 2 (9-10): : 1007 - 1016
  • [30] ANALYSIS AND MANAGEMENT OF SET-UP UNCERTAINTIES IN GYNAECOLOGICAL CANCER RADIOTHERAPY
    Jurado Bruggeman, D.
    Munoz, C.
    Marruecos, J.
    Vayreda, J.
    Canals, E.
    Anglada, L.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S430 - S431