MR safety assessment of active implantable medical devices

被引:0
|
作者
Aissani, Sarra [1 ]
Laistler, Elmar [3 ,4 ]
Felblinger, Jacques [1 ,2 ]
机构
[1] Univ Lorraine, CHRU Nancy Brabois, IADI, INSERM,U1254, Batiment Rech Anciennement EFS,Rez Chausse, F-54511 Nancy, France
[2] CHRU Nancy Brabois, CIC 1433 Innovat Technol, INSERM, Nancy, France
[3] Med Univ Vienna, Ctr Med Phys & Biomed Engn, Vienna, Austria
[4] Med Univ Vienna, MR Ctr Excellence, Vienna, Austria
来源
RADIOLOGE | 2019年 / 59卷 / SUPPL 1期
关键词
Magnetic resonance imaging; Malfunction; Rectification; Heating; Compatibility; CURRENTS; SENSOR; SYSTEM; FIELDS; LEADS;
D O I
10.1007/s00117-019-0541-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Increasing numbers of patients with active implantable medical devices (AIMDs) require magnetic resonance (MR) examinations. The manufacturers are continuing to improve the MR compatibility of their AIMDs. To this end, a variety of measurement methods and numerical simulations are used to evaluate the risks associated with magnetic resonance imaging (MRI). Objective In this article, test methods used to investigate interactions between AIMDs with radio frequency fields and time-varying magnetic gradient fields are reviewed. Materials and methods A literature review of known test methods for radio frequency and gradient field exposure of AIMDs with leads, in particular for neurostimulators, cochlear implants, and implanted infusion pumps, is presented. The state of the art and promising methods are discussed. Results ISO/TS 10974 describes the design of high frequency and gradient injection setups to test conductive materials. A large number of sensor designs have been published to measure the induced voltages and currents through radio frequency and gradient fields and for monitoring AIMDs during MR examinations in in vitro tests. Conclusion The test methods should be planned to be as conservative as possible to cover the worst case scenario. However, in vitro measurements and computer simulation are far from being able to cover all possible configurations in their complexity and uniqueness. For safer MR examinations, current research recommends in vivo testing prior to MR, parallel radiofrequency transmission techniques, and new sequences with reduced energy input in the presence of AIMDs.
引用
收藏
页码:40 / 45
页数:6
相关论文
共 50 条
  • [21] Electromagnetic Susceptibility of Implantable Medical Devices: An Experimental Assessment
    Urbina, R.
    Cucaita, Z.
    Barajas, M.
    Pineda, E.
    Perez, M.
    Araque, J. L.
    2023 17TH EUROPEAN CONFERENCE ON ANTENNAS AND PROPAGATION, EUCAP, 2023,
  • [22] MRI compatibility and visibility assessment of implantable medical devices
    Schueler, BA
    Parrish, TB
    Lin, JC
    Hammer, BE
    Pangrle, BJ
    Ritenour, ER
    Kucharczyk, J
    Truwit, CL
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1999, 9 (04): : 596 - 603
  • [23] Challenges of Evaluating the Safety Profile of Non-active Implantable Medical Devices Compared to that of Medicinal Products
    Pane, J.
    Coloma, P. M.
    Rebollo, I.
    DRUG SAFETY, 2015, 38 (10) : 956 - 956
  • [24] Characteristics and progress of research on the reliability of active implantable medical devices
    Wang W.
    Li B.
    Li L.
    Qinghua Daxue Xuebao/Journal of Tsinghua University, 2023, 63 (05): : 792 - 801
  • [25] Molecular Sieves as Getter Material for Active Implantable Medical Devices
    Kohler, F.
    Porro, Y.
    Stieglitz, T.
    Schuettler, M.
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2012, 57 : 854 - 854
  • [26] Impact of Electromagnetic Fields in Transport on Active Implantable Medical Devices
    Mydlova, Jana
    Galova, Ivana
    Benova, Mariana
    13TH INTERNATIONAL SCIENTIFIC CONFERENCE ON SUSTAINABLE, MODERN AND SAFE TRANSPORT (TRANSCOM 2019), 2019, 40 : 1497 - 1503
  • [27] Key Considerations for Power Management in Active Implantable Medical Devices
    Haci, Dorian
    Liu, Yan
    Ghoreishizadeh, Sara S.
    Constandinou, Timothy G.
    2020 IEEE 11TH LATIN AMERICAN SYMPOSIUM ON CIRCUITS & SYSTEMS (LASCAS), 2020,
  • [28] Testing methods for MR safety and compatibility of medical devices
    Schaefers, G
    Melzer, A
    MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 2006, 15 (02) : 71 - 75
  • [29] A simple apparatus for safety assessment of magnetically induced torque on active implantable medical devices (AIMDs) under 1.5 T and 3.0 T MRI
    Hyo-Chang Seo
    Yongkwan Lee
    Segyeong Joo
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2021, 34 : 767 - 774
  • [30] A simple apparatus for safety assessment of magnetically induced torque on active implantable medical devices (AIMDs) under 1.5 T and 3.0 T MRI
    Seo, Hyo-Chang
    Lee, Yongkwan
    Joo, Segyeong
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2021, 34 (05) : 767 - 774