Cladding Modified with PANI-Oxalic Acid Composite Glucose Oxidase Immobilized Fiber Optic Intrinsic Glucose Biosensor

被引:1
|
作者
Pahurkar, Vikas [1 ]
Dagdale, Shivaji [1 ]
Tamgadge, Yuoraj [2 ]
Nagale, Vinod [3 ]
Muley, Gajanan [1 ]
机构
[1] St Gadge Baba Amravati Univ, Dept Phys, Amravati 444602, Maharashtra, India
[2] Mahatma Fule Mahavidyalaya, Dept Phys, Amravati 444906, Maharashtra, India
[3] St Gadge Baba Amravati Univ, Dept Zool, Amravati 444602, Maharashtra, India
关键词
biosensor; cladding modification; optical fiber; polyaniline; polymerization;
D O I
10.1002/masy.201400248
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
Polyaniline (PANI) and its composites have drawn considerable interest because of their economical importance, good environmental stability and satisfactory conductivity among the conductive polymers. Polymers are playing an increasingly important role in the development of biosensors. The use of conducting polymer composites for the construction of biosensor is increasing nowadays for the immobilization of biomolecules as it enhances the activity and performance of the sensor. In the present investigation, we have used PANI-oxalic acid (OA) for the cladding modification to prepare fiber optic intrinsic glucose biosensor (FOIGB) for detection of glucose. PANI-OA composite have shown good binding toward enzyme-glucose oxidase (GOx) and high biological activity that results in enhanced sensing characteristics. This investigation highlights approach to synthesize PANI-OA composite and its applications in cladding modified FOIB technology. The characterizations were made using X-ray diffraction and scanning electron microscopy (SEM) techniques. The results revealed the formation of homogeneous, PANI-OA film on sensing element. The sensing response of FOIGB toward glucose was measured by monitoring variation in power with varying glucose concentration.
引用
收藏
页码:149 / 151
页数:3
相关论文
共 50 条
  • [41] Potentiometric glucose sensor based on the glucose oxidase immobilized iron ferrite magnetic particle/chitosan composite modified gold coated glass electrode
    Khun, K.
    Ibupoto, Z. H.
    Lu, J.
    AlSalhi, M. S.
    Atif, M.
    Ansari, Anees A.
    Willander, M.
    SENSORS AND ACTUATORS B-CHEMICAL, 2012, 173 : 698 - 703
  • [42] Amperometric glucose biosensor with remarkable acid stability based on glucose oxidase entrapped in colloidal gold-modified carbon ionic liquid electrode
    Liu, Xiaoying
    Zeng, Xiandong
    Mai, Nannan
    Liu, Yong
    Kong, Bo
    Li, Yonghong
    Wei, Wanzhi
    Luo, Shenglian
    BIOSENSORS & BIOELECTRONICS, 2010, 25 (12): : 2675 - 2679
  • [43] A Mediator-Free Bienzyme Amperometric Biosensor Based on Horseradish Peroxidase and Glucose Oxidase Immobilized on Carbon Nanotube Modified Electrode
    Yao, Yan-Li
    Shiu, Kwok-Keung
    ELECTROANALYSIS, 2008, 20 (19) : 2090 - 2095
  • [44] Renewable regeneration optic fiber glucose sensor based on succinylaminobenzenoboronic acid modified excessively tilted fiber grating
    Guo, Xiaoxia
    Cai, Jiapeng
    Meng, Qingao
    Liu, Yue
    Cai, Le
    Yang, Shaoxian
    Zhao, Weiliang
    Zou, Meng
    Su, Jiangtao
    Dai, Heshuang
    Yan, Zhijun
    ANALYTICA CHIMICA ACTA, 2024, 1324
  • [45] DIRECT ELECTRON-TRANSFER WITH GLUCOSE-OXIDASE IMMOBILIZED ON AMINOPHENYLBORONIC ACID - MODIFIED GLASSY-CARBON
    NARASIMHAN, K
    WINGARD, LB
    ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1987, 501 : 298 - 301
  • [46] A nonenzymic microfiber optic-biosensor modified phenylboric acid for sensitively and specifically detecting low glucose concentration
    Ma, Chenfei
    Sun, Kang
    Wang, Guoquan
    Wang, Guanjun
    Sun, Dandan
    Ma, Jie
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2023, 303
  • [47] An amperometric glucose biosensor constructed by immobilizing glucose oxidase on titanium-containing mesoporous composite material of no. 41 modified screen-printed electrodes
    Dai, Zhihui
    Fang, Min
    Bao, Jianchun
    Wang, Huaisheng
    Lu, Tianhong
    ANALYTICA CHIMICA ACTA, 2007, 591 (02) : 195 - 199
  • [48] Electrochemical Studies of Biocatalytic Activity to Glucose Oxidation of Glucose Oxidase Immobilized on Gold/Poly (Glutamic Acid) Modified Electrode Using Quinhydrone as Electron Acceptor
    Zhou, Xuechou
    Zhuang, Zhen
    Zheng, Shiying
    Zheng, Xinyu
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2016, 163 (14) : G201 - G205
  • [49] A temperature-triggered fiber optic biosensor based on hydrogel-magnetic immobilized enzyme complex for sequential determination of cholesterol and glucose
    Huang, Jun
    Liu, Yanxia
    Zhang, Peipei
    Li, Yangjie
    Ding, Liyun
    BIOCHEMICAL ENGINEERING JOURNAL, 2017, 125 : 123 - 128
  • [50] Fabrication of glucose biosensor based on encapsulation of glucose-oxidase on sol-gel composite at the surface of glassy carbon electrode modified with carbon nanotubes and Celestine blue
    Noorbakhsh, Abdollah
    Salimi, Abdollah
    Sharifi, Ensiyeh
    ELECTROANALYSIS, 2008, 20 (16) : 1788 - 1797