摘要
Polyaniline (PANI) and its composites have drawn considerable interest because of their economical importance, good environmental stability and satisfactory conductivity among the conductive polymers. Polymers are playing an increasingly important role in the development of biosensors. The use of conducting polymer composites for the construction of biosensor is increasing nowadays for the immobilization of biomolecules as it enhances the activity and performance of the sensor. In the present investigation, we have used PANI-oxalic acid (OA) for the cladding modification to prepare fiber optic intrinsic glucose biosensor (FOIGB) for detection of glucose. PANI-OA composite have shown good binding toward enzyme-glucose oxidase (GOx) and high biological activity that results in enhanced sensing characteristics. This investigation highlights approach to synthesize PANI-OA composite and its applications in cladding modified FOIB technology. The characterizations were made using X-ray diffraction and scanning electron microscopy (SEM) techniques. The results revealed the formation of homogeneous, PANI-OA film on sensing element. The sensing response of FOIGB toward glucose was measured by monitoring variation in power with varying glucose concentration.
引用
收藏
页码:149 / 151
页数:3
相关论文
共 50 条
  • [21] A novel impedimetric glucose biosensor based on immobilized glucose oxidase on a CuO-Chitosan nanobiocomposite modified FTO electrode
    Asrami, Padideh Naderi
    Mozaffari, Sayed Ahmad
    Tehrani, Mohammad Saber
    Azar, Parviz Aberoomand
    INTERNATIONAL JOURNAL OF BIOLOGICAL MACROMOLECULES, 2018, 118 : 649 - 660
  • [22] Composite glucose biosensor based on screen-printed electrodes bulk modified with Prussian blue and glucose oxidase
    Pravda, M
    O'Halloran, MP
    Kreuzer, MP
    Guilbault, GG
    ANALYTICAL LETTERS, 2002, 35 (06) : 959 - 970
  • [23] PEG-modified glucose oxidase immobilized on a PVA cryogel membrane for amperometric biosensor applications
    Doretti, L
    Ferrara, D
    Gattolin, P
    Lora, S
    Schiavon, F
    Veronese, FM
    TALANTA, 1998, 45 (05) : 891 - 898
  • [24] Glucose biosensor based on glucose oxidase immobilized in sol-gel chitosan/silica hybrid composite film on Prussian blue modified glass carbon electrode
    Tan, XC
    Tian, YX
    Cai, PX
    Zou, XY
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 381 (02) : 500 - 507
  • [25] A novel glucose biosensor constructed by glucose oxidase immobilized with methylene blue intercalated layered lanthanum niobic acid nanocomposite
    Zhang, Xiaobo
    Shen, Liqun
    Wang, Mingyan
    Siqin, Gaowa
    Tong, Zhiwei
    Xu, Ruibo
    Zhang, Dongen
    Ma, Juanjuan
    Liu, Lin
    MATERIALS LETTERS, 2014, 135 : 39 - 42
  • [26] Reagentless glucose biosensor based on direct electron transfer of glucose oxidase immobilized on colloidal gold modified carbon paste electrode
    Liu, SQ
    Ju, HX
    BIOSENSORS & BIOELECTRONICS, 2003, 19 (03): : 177 - 183
  • [27] Ultrasensitive polyaniline-nickel oxide cladding modified with urease immobilized intrinsic optical fiber urea biosensor
    Botewad, Sunil N.
    Gaikwad, Dhammajyot K.
    Girhe, Nitin B.
    Pawar, Pravina P.
    POLYMERS FOR ADVANCED TECHNOLOGIES, 2022, 33 (01) : 189 - 197
  • [28] Development of a high analytical performance amperometric glucose biosensor based on glucose oxidase immobilized in a composite matrix: layered double hydroxides/chitosan
    Qiaofang Shi
    En Han
    Dan Shan
    Wenjuan Yao
    Huaiguo Xue
    Bioprocess and Biosystems Engineering, 2008, 31 : 519 - 526
  • [29] Development of a high analytical performance amperometric glucose biosensor based on glucose oxidase immobilized in a composite matrix: layered double hydroxides/chitosan
    Shi, Qiaofang
    Han, En
    Shan, Dan
    Yao, Wenjuan
    Xue, Huaiguo
    BIOPROCESS AND BIOSYSTEMS ENGINEERING, 2008, 31 (06) : 519 - 526