Cladding Modified with PANI-Oxalic Acid Composite Glucose Oxidase Immobilized Fiber Optic Intrinsic Glucose Biosensor

被引:1
|
作者
Pahurkar, Vikas [1 ]
Dagdale, Shivaji [1 ]
Tamgadge, Yuoraj [2 ]
Nagale, Vinod [3 ]
Muley, Gajanan [1 ]
机构
[1] St Gadge Baba Amravati Univ, Dept Phys, Amravati 444602, Maharashtra, India
[2] Mahatma Fule Mahavidyalaya, Dept Phys, Amravati 444906, Maharashtra, India
[3] St Gadge Baba Amravati Univ, Dept Zool, Amravati 444602, Maharashtra, India
关键词
biosensor; cladding modification; optical fiber; polyaniline; polymerization;
D O I
10.1002/masy.201400248
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
Polyaniline (PANI) and its composites have drawn considerable interest because of their economical importance, good environmental stability and satisfactory conductivity among the conductive polymers. Polymers are playing an increasingly important role in the development of biosensors. The use of conducting polymer composites for the construction of biosensor is increasing nowadays for the immobilization of biomolecules as it enhances the activity and performance of the sensor. In the present investigation, we have used PANI-oxalic acid (OA) for the cladding modification to prepare fiber optic intrinsic glucose biosensor (FOIGB) for detection of glucose. PANI-OA composite have shown good binding toward enzyme-glucose oxidase (GOx) and high biological activity that results in enhanced sensing characteristics. This investigation highlights approach to synthesize PANI-OA composite and its applications in cladding modified FOIB technology. The characterizations were made using X-ray diffraction and scanning electron microscopy (SEM) techniques. The results revealed the formation of homogeneous, PANI-OA film on sensing element. The sensing response of FOIGB toward glucose was measured by monitoring variation in power with varying glucose concentration.
引用
收藏
页码:149 / 151
页数:3
相关论文
共 50 条
  • [11] Glucose biosensor based on a platinum electrode modified with rhodium nanoparticles and with glucose oxidase immobilized on gold nanoparticles
    Xishan Guo
    Bo Liang
    Jinming Jian
    Yelei Zhang
    Xuesong Ye
    Microchimica Acta, 2014, 181 : 519 - 525
  • [12] Amperometric Glucose Biosensor Based on Titanium Electrode Modified with Prussian Blue Layer and Immobilized Glucose Oxidase
    Valiuniene, A.
    Virbickas, P.
    Rekertaite, A.
    Ramanavicius, A.
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2017, 164 (14) : B781 - B784
  • [13] Glucose biosensor based on a platinum electrode modified with rhodium nanoparticles and with glucose oxidase immobilized on gold nanoparticles
    Guo, Xishan
    Liang, Bo
    Jian, Jinming
    Zhang, Yelei
    Ye, Xuesong
    MICROCHIMICA ACTA, 2014, 181 (5-6) : 519 - 525
  • [14] S-shaped long period fiber grating glucose concentration biosensor based on immobilized glucose oxidase
    Wu, Chao-Wei
    OPTIK, 2020, 203
  • [15] A glucose biosensor based on direct electrochemistry of glucose oxidase immobilized onto platinum nanoparticles modified graphene electrode
    LIU AiRong1* & HUANG ShiMing2 1 State Key Laboratory of Pollution Control and Resources Reuse
    2 Department of Physics
    Science China(Physics,Mechanics & Astronomy), 2012, Mechanics & Astronomy)2012 (07) : 1163 - 1167
  • [16] A glucose biosensor based on direct electrochemistry of glucose oxidase immobilized onto platinum nanoparticles modified graphene electrode
    AiRong Liu
    ShiMing Huang
    Science China Physics, Mechanics and Astronomy, 2012, 55 : 1163 - 1167
  • [17] A glucose biosensor based on direct electrochemistry of glucose oxidase immobilized onto platinum nanoparticles modified graphene electrode
    Liu AiRong
    Huang ShiMing
    SCIENCE CHINA-PHYSICS MECHANICS & ASTRONOMY, 2012, 55 (07) : 1163 - 1167
  • [18] Development and Study the Performance of PBA Cladding Modified Fiber Optic Intrinsic Biosensor for Urea Detection
    Botewad, S. N.
    Pahurkar, V. G.
    Muley, G. G.
    INTERNATIONAL CONFERENCE ON CONDENSED MATTER AND APPLIED PHYSICS (ICC 2015), 2016, 1728
  • [19] Glucose biosensor based on glucose oxidase immobilized in sol–gel chitosan/silica hybrid composite film on Prussian blue modified glass carbon electrode
    Xue-Cai Tan
    Yuan-Xin Tian
    Pei-Xiang Cai
    Xiao-Yong Zou
    Analytical and Bioanalytical Chemistry, 2005, 381 : 500 - 507
  • [20] Glucose Biosensor Based on Glucose Oxidase Immobilized on BSA Cross-Linked Nanocomposite Modified Glassy Carbon Electrode
    Li, Yang-Yang
    Ma, Xin-Xin
    Song, Xin-Yan
    Ma, Lin-Lin
    Li, Yu-Ying
    Meng, Xin
    Chen, Yu-Jie
    Xu, Ke-Xin
    Moosavi-Movahedi, Ali Akbar
    Xiao, Bao-Lin
    Hong, Jun
    SENSORS, 2023, 23 (06)