LabPET II, an APD-based Detector Module with PET and Counting CT Imaging Capabilities

被引:27
|
作者
Bergeron, Melanie [1 ,2 ]
Thibaudeau, Christian [1 ,2 ,3 ]
Cadorette, Jules [1 ,2 ]
Tetrault, Marc-Andre [3 ]
Pepin, Catherine M. [1 ,2 ]
Clerk-Lamalice, Julien [1 ,2 ]
Loignon-Houle, Francis [1 ,2 ]
Davies, Murray [4 ]
Dautet, Henri [4 ]
Deschamps, Pierre [4 ]
Fontaine, Rejean [3 ]
Lecomte, Roger [1 ,2 ]
机构
[1] Univ Sherbrooke, Sherbrooke Mol Imaging Ctr, Sherbrooke, PQ J1H 5N4, Canada
[2] Univ Sherbrooke, Dept Nucl Med & Radiobiol, Sherbrooke, PQ J1H 5N4, Canada
[3] Univ Sherbrooke, Dept Elect Engn & Comp Engn, Sherbrooke, PQ J1G 0A2, Canada
[4] Excelitas Technol, Vaudreuil, PQ J7V 8P7, Canada
基金
加拿大健康研究院; 加拿大自然科学与工程研究理事会;
关键词
Avalanche photodiodes (APD); computed tomography (CT); dual modality; positron emission tomography/computed tomography (PET/CT); positron emission tomography (PET); scintillators; ITERATIVE RECONSTRUCTION; COMPUTED-TOMOGRAPHY; ANIMAL PET; MICRO-CT; SIMULATION TOOLKIT; QUALITY; SYSTEMS; RESOLUTION; PERFORMANCE; ELECTRONICS;
D O I
10.1109/TNS.2015.2420796
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Computed tomography (CT) is currently the standard modality to provide anatomical reference for positron emission tomography (PET) in molecular imaging applications. Since both PET and CT rely on detecting radiation to generate images, using the same detection system for data acquisition is a compelling idea even though merging PET and CT hardware imposes stringent requirements on detectors. These requirements include large signal dynamic range with high signal-to-noise ratio for good energy resolution in PET and energy-resolved photon-counting CT, high pixelization for suitable spatial resolution in CT, and high count rate capability for reasonable CT acquisition time. To meet these criteria, the avalanche photodiode (APD)-based LabPET II module is proposed as the building block for a truly combined PET/CT scanner. The module is made of two monolithic 4 x 8 APD pixel arrays mounted side-by-side on a custom ceramic holder. Individual APD pixels have an active area of 1.1 x 1.1 mm(2) at a 1.2 mm pitch. The APD arrays are coupled to a 12-mm high, 8 x 8 LYSO scintillator array made of 1.12 x 1.12 mm(2) pixels also at a pitch of 1.2 mm to ensure direct one-to-one coupling to individual APD pixels. The scintillator array was designed with unbound specular reflective material between pixels to maximize the difference between refractive indices and enhance total internal reflection at the crystal side surfaces for better light collection, and the APD quantum efficiency was improved to similar to 60% at 420 nm to optimize intrinsic detector performance. Mean energy resolution was 20 +/- 1% at 511 keV and 40 +/- 4% at 60 keV. The measured intrinsic spatial and time resolution for PET were respectively 0.81 +/- 0.04 mm FWTM/1.57 +/- 0.04 and 3.6 +/- 0.3 ns FWHM with an energy threshold of 400 keV. Initial phantom images obtained using a CT test bench demonstrated excellent contrast linearity as a function of material density. With a magnification factor of 2, a CT spatial resolution of 0.66 mm FWHM/1.2 mm FWTM, corresponding to 1.18 lp/mm at MTF10% / 0.67 lp/mm at MTF50%, was measured, allowing 0.75 mm air holes in an Ultra-Micro Hot Spot resolution phantom to be clearly distinguished.
引用
收藏
页码:756 / 765
页数:10
相关论文
共 50 条
  • [41] Design and performance of 0.18-μm CMOS charge preamplifiers for APD-based PET scanners
    Robert, S
    Pratte, JF
    DeGeronimo, G
    O'Connor, P
    Stoll, S
    Pepin, CM
    Fontaine, R
    Lecomte, R
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 1242 - 1246
  • [42] Design and performance of 0.18-μm CMOS charge preamplifiers for APD-based PET scanners
    Pratte, JF
    Robert, S
    De Geronimo, G
    O'Connor, P
    Stoll, S
    Pepin, CM
    Fontaine, R
    Lecomte, R
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (05) : 1979 - 1985
  • [43] Real time digital signal processing implementation for an APD-based PET scanner with phoswich detectors
    Fontaine, R.
    Tetrault, M. -A.
    Belanger, F.
    Viscogliosi, N.
    Himmich, R.
    Michaud, J. -B.
    Robert, S.
    Leroux, J. -D.
    Semmaoui, H.
    Berard, P.
    Cadorette, J.
    Pepin, C. M.
    Lecomte, R.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (03) : 784 - 788
  • [44] Impacts of Intelligent Automated Quality Control on a Small Animal APD-Based Digital PET Scanner
    Charest, Jonathan
    Beaudoin, Jean-Francois
    Bergeron, Melanie
    Cadorette, Jules
    Arpin, Louis
    Lecomte, Roger
    Brunet, Charles-Antoine
    Fontaine, Rejean
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2016, 63 (05) : 2550 - 2557
  • [45] Real time coincidence detection system for digital high resolution APD-based animal PET scanner
    Tetrault, Marc-Andre
    Lepage, Martin D.
    Viscogliosi, Nicolas
    Belanger, Francois
    Cadorette, Jules
    Pepin, Catherine Michelle
    Lecomte, Roger
    Fontaine, Rejean
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 2849 - 2853
  • [46] Automatic Channel Fault Detection and Diagnosis System for a Small Animal APD-Based Digital PET Scanner
    Charest, Jonathan
    Beaudoin, Jean-Francois
    Cadorette, Jules
    Lecomte, Roger
    Brunet, Charles-Antoine
    Fontaine, Rejean
    2014 19TH IEEE-NPSS REAL TIME CONFERENCE (RT), 2014,
  • [47] Development of a compact PET detector module for DOI measurement based on LSO, monolithic APD arrays, and integrated preamplifiers.
    Pichler, BJ
    Boening, G
    Rafecas, M
    Pimpl, W
    Lorenz, E
    Schwaiger, M
    Ziegler, SI
    JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (05) : 102P - 102P
  • [48] Performance evaluation of a PET detector module using a continuous LSO scintillator coupled to an APD array
    Léonard, S
    Bruyndonckx, P
    Tavernier, S
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 2160 - 2163
  • [49] Toward truly combined PET/CT imaging using PET detectors and photon counting CT with iterative reconstruction implementing physical detector response
    Thibaudeau, Christian
    Berard, Philippe
    Tetrault, Marc-Andre
    Leroux, Jean-Daniel
    Bergeron, Melanie
    Fontaine, Rejean
    Lecomte, Roger
    MEDICAL PHYSICS, 2012, 39 (09) : 5697 - 5707
  • [50] Automatic Channel Fault Detection and Diagnosis System for a Small Animal APD-Based Digital PET Scanner
    Charest, Jonathan
    Beaudoin, Jean-Francois
    Cadorette, Jules
    Lecomte, Roger
    Brunet, Charles-Antoine
    Fontaine, Rejean
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2015, 62 (03) : 1070 - 1076