LabPET II, an APD-based Detector Module with PET and Counting CT Imaging Capabilities

被引:27
|
作者
Bergeron, Melanie [1 ,2 ]
Thibaudeau, Christian [1 ,2 ,3 ]
Cadorette, Jules [1 ,2 ]
Tetrault, Marc-Andre [3 ]
Pepin, Catherine M. [1 ,2 ]
Clerk-Lamalice, Julien [1 ,2 ]
Loignon-Houle, Francis [1 ,2 ]
Davies, Murray [4 ]
Dautet, Henri [4 ]
Deschamps, Pierre [4 ]
Fontaine, Rejean [3 ]
Lecomte, Roger [1 ,2 ]
机构
[1] Univ Sherbrooke, Sherbrooke Mol Imaging Ctr, Sherbrooke, PQ J1H 5N4, Canada
[2] Univ Sherbrooke, Dept Nucl Med & Radiobiol, Sherbrooke, PQ J1H 5N4, Canada
[3] Univ Sherbrooke, Dept Elect Engn & Comp Engn, Sherbrooke, PQ J1G 0A2, Canada
[4] Excelitas Technol, Vaudreuil, PQ J7V 8P7, Canada
基金
加拿大健康研究院; 加拿大自然科学与工程研究理事会;
关键词
Avalanche photodiodes (APD); computed tomography (CT); dual modality; positron emission tomography/computed tomography (PET/CT); positron emission tomography (PET); scintillators; ITERATIVE RECONSTRUCTION; COMPUTED-TOMOGRAPHY; ANIMAL PET; MICRO-CT; SIMULATION TOOLKIT; QUALITY; SYSTEMS; RESOLUTION; PERFORMANCE; ELECTRONICS;
D O I
10.1109/TNS.2015.2420796
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Computed tomography (CT) is currently the standard modality to provide anatomical reference for positron emission tomography (PET) in molecular imaging applications. Since both PET and CT rely on detecting radiation to generate images, using the same detection system for data acquisition is a compelling idea even though merging PET and CT hardware imposes stringent requirements on detectors. These requirements include large signal dynamic range with high signal-to-noise ratio for good energy resolution in PET and energy-resolved photon-counting CT, high pixelization for suitable spatial resolution in CT, and high count rate capability for reasonable CT acquisition time. To meet these criteria, the avalanche photodiode (APD)-based LabPET II module is proposed as the building block for a truly combined PET/CT scanner. The module is made of two monolithic 4 x 8 APD pixel arrays mounted side-by-side on a custom ceramic holder. Individual APD pixels have an active area of 1.1 x 1.1 mm(2) at a 1.2 mm pitch. The APD arrays are coupled to a 12-mm high, 8 x 8 LYSO scintillator array made of 1.12 x 1.12 mm(2) pixels also at a pitch of 1.2 mm to ensure direct one-to-one coupling to individual APD pixels. The scintillator array was designed with unbound specular reflective material between pixels to maximize the difference between refractive indices and enhance total internal reflection at the crystal side surfaces for better light collection, and the APD quantum efficiency was improved to similar to 60% at 420 nm to optimize intrinsic detector performance. Mean energy resolution was 20 +/- 1% at 511 keV and 40 +/- 4% at 60 keV. The measured intrinsic spatial and time resolution for PET were respectively 0.81 +/- 0.04 mm FWTM/1.57 +/- 0.04 and 3.6 +/- 0.3 ns FWHM with an energy threshold of 400 keV. Initial phantom images obtained using a CT test bench demonstrated excellent contrast linearity as a function of material density. With a magnification factor of 2, a CT spatial resolution of 0.66 mm FWHM/1.2 mm FWTM, corresponding to 1.18 lp/mm at MTF10% / 0.67 lp/mm at MTF50%, was measured, allowing 0.75 mm air holes in an Ultra-Micro Hot Spot resolution phantom to be clearly distinguished.
引用
收藏
页码:756 / 765
页数:10
相关论文
共 50 条
  • [31] HgCdTe APD-based Linear-Mode Photon Counting Components and LADAR Receivers
    Jack, Michael
    Wehner, Justin
    Edwards, John
    Chapman, George
    Hall, Donald N. B.
    Jacobson, Shane M.
    ADVANCED PHOTON COUNTING TECHNIQUES V, 2011, 8033
  • [32] Performance of APD-based monolithic-crystal detectors for small animal PET
    Maas, Marnix C.
    van der Laan, D. J.
    Schaart, Dennis R.
    Bruyndonckx, Peter
    Lemaitre, Cedric
    van Eijk, Carel W. E.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 2017 - 2021
  • [33] Initial Results for Automatic Calibration of the LabPET II Front-End Detector Module
    Jurgensen, Nadia
    Arpin, Louis
    Bouziri, Haithem
    Njejimana, Larissa
    Koua, Konin
    Gaudin, Emilie
    Pratte, Jean-Francois
    Lecomte, Roger
    Fontaine, Rejean
    2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,
  • [34] LabPETtm:: A second-generation APD-based digital scanner for high-resolution small animal PET imaging
    Lecomte, R.
    deKemp, R. A.
    Klein, R.
    Cadorette, J.
    Lepage, M. D.
    Robert, G.
    Selivanov, V.
    Belanger, F.
    Semmaoui, H.
    Tetrault, M. A.
    Viscogliosi, N.
    Bergeron, M.
    Lemieux, F.
    Lemonde, M. A.
    Fontaine, R.
    MEDICAL PHYSICS, 2006, 33 (07) : 2671 - 2671
  • [35] Design and Integration of a High Accuracy Multichannel Analog CMOS Peak Detect and Hold Circuit for APD-Based PET Imaging
    Fang, Xiaochao
    Brasse, David
    Hu-Guo, Christine
    Hu, Yann
    IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2012, 6 (02) : 179 - 187
  • [36] Signal to noise ratio of APD-based monolithic scintillator detectors for high resolution PET
    Maas, Marnix C.
    Schaart, Dennis R.
    van der Laan, D. J.
    van Dam, Herman T.
    Huizenga, Jan
    Brouwer, J. C.
    Bruyndonckx, Peter
    Lemaitre, Cedric
    van Eijk, Carel W. E.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2008, 55 (03) : 842 - 852
  • [37] Automatic Channel Fault Detection on a Small Animal APD-Based Digital PET Scanner
    Charest, Jonathan
    Beaudoin, Jean-Franois
    Cadorette, Jules
    Lecomte, Roger
    Brunet, Charles-Antoine
    Fontaine, Rejean
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2014, 61 (05) : 2494 - 2502
  • [38] Experimental Study of Photo Counting Imaging Based on APD
    Qu Hui-Ming
    Li Yuan-yuan
    Cao Dan
    Zheng Qi
    Ji Zhong-Jie
    Chen Qian
    6TH INTERNATIONAL SYMPOSIUM ON ADVANCED OPTICAL MANUFACTURING AND TESTING TECHNOLOGIES: OPTICAL SYSTEM TECHNOLOGIES FOR MANUFACTURING AND TESTING, 2012, 8420
  • [39] Design of a High Accuracy Multi-channel Analog CMOS Peak Detect and Hold Circuits for APD-Based PET Imaging
    Fang, Xiaochao
    Hu-Guo, Christine
    Brasse, David
    Hu, Yann
    INTERNATIONAL CONFERENCE ON SIGNALS AND ELECTRONIC SYSTEMS (ICSES '10): CONFERENCE PROCEEDINGS, 2010, : 21 - 24
  • [40] Preliminary results of a data acquisition sub-system for distributed, digital, computational, APD-based, dual-modality PET/CT architecture for small animal imaging
    Fontaine, R
    Tétrault, MA
    Bélanger, F
    Viscogliosi, N
    Bérard, P
    Cadorette, J
    Leroux, JD
    Michaud, JB
    Pratte, JF
    Pepin, C
    Robert, S
    Lecomte, R
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 2296 - 2300