A nanohybrid based on porphyrin dye functionalized graphene oxide for the application in non-enzymatic electrochemical sensor

被引:28
|
作者
Wu, Hai [1 ,2 ]
Li, Xiang [1 ]
Chen, Miaomiao [1 ]
Wang, Chang [1 ]
Wei, Ting [1 ]
Zhang, Hong [1 ]
Fan, Suhua [1 ]
机构
[1] Fuyang Normal Univ, Sch Chem & Mat Engn, Fuyang 236037, Anhui, Peoples R China
[2] Hunan Univ, State Key Lab Chemo Biosensing & Chemometr, Changsha 410082, Hunan, Peoples R China
基金
中国国家自然科学基金;
关键词
Porphyrin; Graphene; Electrochemical sensor; Ascorbic acid; OXYGEN REDUCTION REACTION; SENSITIZED SOLAR-CELLS; ASCORBIC-ACID; MODIFIED ELECTRODE; ELECTROCATALYTIC APPLICATION; AQUEOUS-SOLUTION; CARBON; FILMS; FABRICATION; NANOPARTICLES;
D O I
10.1016/j.electacta.2017.10.122
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A zinc porphyrin dye (YD2-o-C8, designated as YD) noncovalently functionalized graphene oxide (GO) nanohybrid (GO@YD) was facilely synthesized through hydrogen bonding and pi-pi stacking interaction, which was characterized by spectroscopic techniques, electrochemistry, and density functional theory (DFT). The fast electrons transfer from YD to GO and the low binding energy occurred in GO@YD nanohybrid suggest that the nanohybrid possesses remarkable electrochemical properties. However, the inner electroactivity of insoluble YD on GO could be aroused only by combining cationic surfactant of tetraoctylammonium bromide (TOAB). Therefore, the GO@YD nanohybrid encapsulated by TOAB was firstly modified on glassy carbon electrode (GCE) to fabricate the TOAB/GO@YD/GCE, which was then electrochemically reduced to obtain the fabricated sensor (TOAB/ERGO@YD/GCE). The sensor was employed to sense ascorbic acid (AA) and it showed a high sensitivity of 13.58 mu A mM(-1), a wide linear concentration from 1.33 mu M to 1.46 mM (R = 0.998), and a limit of detection (LOD) as low as 0.28 mu M. The sensor not only showed high selectivity but also exhibited excellent operational and storage stability due to the hydrophobicity of TOAB. The great potential of the TOAB/ERGO@YD/GCE for practical and reliable AA analysis in the fields of food analysis, clinical tests, and the pharmaceutical industry suggests that the electron mediator of YD combined with the electron accelerator of ERGO and the electron rouser of TOAB possesses special advantages for fabricating non-enzymatic electrochemical sensor. (c) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:355 / 364
页数:10
相关论文
共 50 条
  • [31] Nickel-functionalized reduced graphene oxide with polyaniline for non-enzymatic glucose sensing
    Zhang, Bing
    He, Yu
    Liu, Bingqian
    Tang, Dianping
    MICROCHIMICA ACTA, 2015, 182 (3-4) : 625 - 631
  • [32] Carbon-supported nickel/nickel oxide nanohybrid composite as a high-performance sensor for electrochemical non-enzymatic glucose detection
    Ramu, Jagadish
    Ramasundaram, Subramaniyan
    Yellappa, Shivaraj
    Gunamalai, Lavanya
    Kamilya, Tapas
    Afzal, Mohd
    Jeffery, A. Anto
    Oh, Tae Hwan
    Mahanthappa, Mallappa
    Vishwanath, R. S.
    NEW JOURNAL OF CHEMISTRY, 2024, 48 (31) : 13814 - 13824
  • [33] A non-enzymatic electrochemical sensor for detection of sialic acid based on a porphine/graphene oxide modified electrode via indicator displacement assay
    Liu, Tailin
    Fu, Bo
    Chen, Jincheng
    Yan, Zhihong
    Li, Kang
    ELECTROCHIMICA ACTA, 2018, 269 : 136 - 143
  • [34] A sensitive non-enzymatic electrochemical glucose sensor based on a ZnO/Co3O4/reduced graphene oxide nanocomposite
    Hussein, Beshir A.
    Tsegaye, Abebaw A.
    Shifera, Getabalew
    M. Taddesse, Abi
    SENSORS & DIAGNOSTICS, 2023, 2 (02): : 347 - 360
  • [35] Composites of Reduced Graphene Oxide/Nickel Submicrorods for Non-Enzymatic Electrochemical Biosensing: Application to Amperometric Glucose Detection
    Mohammadzadeh, Amirmahdi
    Mazaheri, Mozhdeh
    Sedighian, Armin
    Ghanbari, Hajar
    Simchi, Abdolreza
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2020, 167 (08)
  • [36] Non-enzymatic free bilirubin electrochemical sensor based on ceria nanocube
    Lu, Zhan-Jun
    Cheng, Yarong
    Zhang, Yuan
    Wang, Xuefeng
    Xu, Pengcheng
    Yu, Haitao
    Li, Xinxin
    SENSORS AND ACTUATORS B-CHEMICAL, 2021, 329
  • [37] Enzymatic and non-enzymatic electrochemical glucose sensor based on carbon nano-onions
    Mohapatra, Jeotikanta
    Ananthoju, Balakrishna
    Nair, Vishnu
    Mitra, Arijit
    Bahadur, D.
    Medhekar, N. V.
    Aslam, M.
    APPLIED SURFACE SCIENCE, 2018, 442 : 332 - 341
  • [38] A non-enzymatic urea sensor based on the nickel sulfide/graphene oxide modified glassy carbon electrode
    Naik, T. S. Sunil Kumar
    Saravanan, S.
    Saravana, K. N. Sri
    Pratiush, Utkarsh
    Ramamurthy, Praveen C.
    MATERIALS CHEMISTRY AND PHYSICS, 2020, 245
  • [39] Non-enzymatic glucose electrochemical sensor based on silver nanoparticle decorated organic functionalized multiwall carbon nanotubes
    Ensafi, Ali A.
    Zandi-Atashbar, N.
    Rezaei, B.
    Ghiaci, M.
    Chermahini, M. Esmaeili
    Moshiri, P.
    RSC ADVANCES, 2016, 6 (65): : 60926 - 60932
  • [40] Highly sensitive non-enzymatic glucose sensor based on Pt nanoparticle decorated graphene oxide hydrogel
    Hoa, Le Thuy
    Sun, Kang Gyu
    Hur, Seung Hyun
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 210 : 618 - 623