A nanohybrid based on porphyrin dye functionalized graphene oxide for the application in non-enzymatic electrochemical sensor

被引:28
|
作者
Wu, Hai [1 ,2 ]
Li, Xiang [1 ]
Chen, Miaomiao [1 ]
Wang, Chang [1 ]
Wei, Ting [1 ]
Zhang, Hong [1 ]
Fan, Suhua [1 ]
机构
[1] Fuyang Normal Univ, Sch Chem & Mat Engn, Fuyang 236037, Anhui, Peoples R China
[2] Hunan Univ, State Key Lab Chemo Biosensing & Chemometr, Changsha 410082, Hunan, Peoples R China
基金
中国国家自然科学基金;
关键词
Porphyrin; Graphene; Electrochemical sensor; Ascorbic acid; OXYGEN REDUCTION REACTION; SENSITIZED SOLAR-CELLS; ASCORBIC-ACID; MODIFIED ELECTRODE; ELECTROCATALYTIC APPLICATION; AQUEOUS-SOLUTION; CARBON; FILMS; FABRICATION; NANOPARTICLES;
D O I
10.1016/j.electacta.2017.10.122
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A zinc porphyrin dye (YD2-o-C8, designated as YD) noncovalently functionalized graphene oxide (GO) nanohybrid (GO@YD) was facilely synthesized through hydrogen bonding and pi-pi stacking interaction, which was characterized by spectroscopic techniques, electrochemistry, and density functional theory (DFT). The fast electrons transfer from YD to GO and the low binding energy occurred in GO@YD nanohybrid suggest that the nanohybrid possesses remarkable electrochemical properties. However, the inner electroactivity of insoluble YD on GO could be aroused only by combining cationic surfactant of tetraoctylammonium bromide (TOAB). Therefore, the GO@YD nanohybrid encapsulated by TOAB was firstly modified on glassy carbon electrode (GCE) to fabricate the TOAB/GO@YD/GCE, which was then electrochemically reduced to obtain the fabricated sensor (TOAB/ERGO@YD/GCE). The sensor was employed to sense ascorbic acid (AA) and it showed a high sensitivity of 13.58 mu A mM(-1), a wide linear concentration from 1.33 mu M to 1.46 mM (R = 0.998), and a limit of detection (LOD) as low as 0.28 mu M. The sensor not only showed high selectivity but also exhibited excellent operational and storage stability due to the hydrophobicity of TOAB. The great potential of the TOAB/ERGO@YD/GCE for practical and reliable AA analysis in the fields of food analysis, clinical tests, and the pharmaceutical industry suggests that the electron mediator of YD combined with the electron accelerator of ERGO and the electron rouser of TOAB possesses special advantages for fabricating non-enzymatic electrochemical sensor. (c) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:355 / 364
页数:10
相关论文
共 50 条
  • [1] Non-enzymatic electrochemical glucose sensor based on platinum nanoflowers supported on graphene oxide
    Wu, Geng-huang
    Song, Xin-hong
    Wu, Yan-fan
    Chen, Xiao-mei
    Luo, Feng
    Chen, Xi
    TALANTA, 2013, 105 : 379 - 385
  • [2] Non-enzymatic Glucose Sensor Based on Graphene Oxide/ZnO Nanoarrays
    Liang X.
    Han L.
    Lei Y.
    Li W.
    Huang R.
    Chen R.
    Ni H.
    Zhan W.
    Cailiao Daobao/Materials Reports, 2022, 36 (13):
  • [3] Graphene oxide/silver nanocomposite based non-enzymatic glucose sensor
    Singhal A.
    Anand V.K.
    Virdi G.S.
    Singhal, Anuj, 2018, American Scientific Publishers (12): : 397 - 400
  • [4] Porous graphene oxide based disposable non-enzymatic electrochemical sensor for the determination of nicotinamide adenine dinucleotide
    Elancheziyan, Mari
    Theyagarajan, K.
    Ponnusamy, Vinoth Kumar
    Thenmozhi, Kathavarayan
    Senthilkumar, Sellappan
    MICRO AND NANO ENGINEERING, 2022, 15
  • [5] Non-enzymatic electrochemical sensor for nitrite based on a graphene oxide-polyaniline-Au nanoparticles nanocomposite
    Chen, Guozhen
    Zheng, Jianbin
    MICROCHEMICAL JOURNAL, 2021, 164
  • [6] Development of Non-enzymatic Electrochemical Glucose Sensor Based on Graphene Oxide Nanoribbon - Gold Nanoparticle Hybrid
    Ismail, Nur Syakimah
    Le, Quynh Hoa
    Yoshikawa, Hiroyuki
    Saito, Masato
    Tamiya, Eiichi
    ELECTROCHIMICA ACTA, 2014, 146 : 98 - 105
  • [7] Graphene/PEDOT/Ni-Based electrochemical Non-Enzymatic glucose sensor
    Ma, Qinzheng
    Zhang, Ying
    Wang, Luwei
    Yang, Yushuai
    Wang, Wei
    MICROCHEMICAL JOURNAL, 2024, 206
  • [8] A non-enzymatic hydrogen peroxide sensor based on dendrimer functionalized magnetic graphene oxide decorated with palladium nanoparticles
    Baghayeri, Mehdi
    Alinezhad, Heshmatollah
    Tarahomi, Mehrasa
    Fayazi, Maryam
    Ghanei-Motlagh, Masoud
    Maleki, Behrooz
    APPLIED SURFACE SCIENCE, 2019, 478 : 87 - 93
  • [9] Direct electrochemical non-enzymatic assay of glucose using functionalized graphene
    Malledevaru Mallesha
    Revanasiddappa Manjunatha
    Gurukar Shivappa Suresh
    Jose Savio Melo
    S. F. D’Souza
    Thimmappa Venkatarangaiah Venkatesha
    Journal of Solid State Electrochemistry, 2012, 16 : 2675 - 2681
  • [10] Non-enzymatic electrochemical detection of cholesterol using β-cyclodextrin functionalized graphene
    Agnihotri, Nidhi
    Chowdhury, Ankan Dutta
    De, Amitabha
    BIOSENSORS & BIOELECTRONICS, 2015, 63 : 212 - 217