A nanohybrid based on porphyrin dye functionalized graphene oxide for the application in non-enzymatic electrochemical sensor

被引:28
|
作者
Wu, Hai [1 ,2 ]
Li, Xiang [1 ]
Chen, Miaomiao [1 ]
Wang, Chang [1 ]
Wei, Ting [1 ]
Zhang, Hong [1 ]
Fan, Suhua [1 ]
机构
[1] Fuyang Normal Univ, Sch Chem & Mat Engn, Fuyang 236037, Anhui, Peoples R China
[2] Hunan Univ, State Key Lab Chemo Biosensing & Chemometr, Changsha 410082, Hunan, Peoples R China
基金
中国国家自然科学基金;
关键词
Porphyrin; Graphene; Electrochemical sensor; Ascorbic acid; OXYGEN REDUCTION REACTION; SENSITIZED SOLAR-CELLS; ASCORBIC-ACID; MODIFIED ELECTRODE; ELECTROCATALYTIC APPLICATION; AQUEOUS-SOLUTION; CARBON; FILMS; FABRICATION; NANOPARTICLES;
D O I
10.1016/j.electacta.2017.10.122
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A zinc porphyrin dye (YD2-o-C8, designated as YD) noncovalently functionalized graphene oxide (GO) nanohybrid (GO@YD) was facilely synthesized through hydrogen bonding and pi-pi stacking interaction, which was characterized by spectroscopic techniques, electrochemistry, and density functional theory (DFT). The fast electrons transfer from YD to GO and the low binding energy occurred in GO@YD nanohybrid suggest that the nanohybrid possesses remarkable electrochemical properties. However, the inner electroactivity of insoluble YD on GO could be aroused only by combining cationic surfactant of tetraoctylammonium bromide (TOAB). Therefore, the GO@YD nanohybrid encapsulated by TOAB was firstly modified on glassy carbon electrode (GCE) to fabricate the TOAB/GO@YD/GCE, which was then electrochemically reduced to obtain the fabricated sensor (TOAB/ERGO@YD/GCE). The sensor was employed to sense ascorbic acid (AA) and it showed a high sensitivity of 13.58 mu A mM(-1), a wide linear concentration from 1.33 mu M to 1.46 mM (R = 0.998), and a limit of detection (LOD) as low as 0.28 mu M. The sensor not only showed high selectivity but also exhibited excellent operational and storage stability due to the hydrophobicity of TOAB. The great potential of the TOAB/ERGO@YD/GCE for practical and reliable AA analysis in the fields of food analysis, clinical tests, and the pharmaceutical industry suggests that the electron mediator of YD combined with the electron accelerator of ERGO and the electron rouser of TOAB possesses special advantages for fabricating non-enzymatic electrochemical sensor. (c) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:355 / 364
页数:10
相关论文
共 50 条
  • [21] Non-enzymatic electrochemical detection of caffeic acid in food samples with spinel magnesium cobalt oxide incorporated graphene nanohybrid electrocatalyst
    Priya, Thangavelu Sakthi
    Nataraj, Nandini
    Chen, Tse-Wei
    Chen, Shen-Ming
    Tamilalagan, Elayappan
    Lou, Bih-Show
    Al-Mohaimeed, Amal M.
    Binobead, Manal Abdulaziz
    Elshikh, Mohamed S.
    JOURNAL OF ALLOYS AND COMPOUNDS, 2024, 1002
  • [22] Non-enzymatic hydrogen peroxide detection on a novel nanohybrid composite of chitosan and grafted graphene oxide
    Nasir, Amara
    Khalid, Sadia
    Mazare, Anca
    Yasin, Tariq
    MATERIALS RESEARCH BULLETIN, 2023, 167
  • [23] Assessment of graphene oxide/MgA1 oxide nanocomposite as a non-enzymatic sensor for electrochemical quantification of hydrogen peroxide
    Bin Asif, Safi Asim
    Khan, Sher Bahadar
    Asiri, Abdullah M.
    JOURNAL OF THE TAIWAN INSTITUTE OF CHEMICAL ENGINEERS, 2017, 74 : 255 - 262
  • [24] Non-enzymatic electrochemical sensor to detect γ-aminobutyric acid with ligand-based on graphene oxide modi fied gold electrode
    Alamry, Khalid A.
    Hussein, Mahmoud A.
    Choi, Jeong-woo
    El-Said, Waleed A.
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2020, 879
  • [25] Fabrication of Non-enzymatic Electrochemical Glucose Sensor Based on Pd-Mn Alloy Nanoparticles Supported on Reduced Graphene Oxide
    Waqas, Muhammad
    Lan, Jianjun
    Zhang, Xiaoxia
    Fan, Youjun
    Zhang, Panyu
    Liu, Chengzhou
    Jiang, Zhe
    Wang, Xiaoqu
    Zeng, Jianqiang
    Chen, Wei
    ELECTROANALYSIS, 2020, 32 (06) : 1226 - 1236
  • [26] Non-enzymatic Amperometric Glucose Sensor Based on Copper Nanowires Decorated Reduced Graphene Oxide
    Ju, Lele
    Wu, Guosong
    Lu, Biao
    Li, Xiaoyun
    Wu, Huaping
    Liu, Aiping
    ELECTROANALYSIS, 2016, 28 (10) : 2543 - 2551
  • [27] A non-enzymatic glucose sensor based on the CuS nanoflakes-reduced graphene oxide nanocomposite
    Yan, Xiaoyi
    Gu, Yue
    Li, Cong
    Zheng, Bo
    Li, Yaru
    Zhang, Tingting
    Zhang, Zhiquan
    Yang, Ming
    ANALYTICAL METHODS, 2018, 10 (03) : 381 - 388
  • [28] Preparation of cuprous oxide-supported silver-modified reduced graphene oxide nanocomposites for non-enzymatic electrochemical sensor
    Qian, Yuhong
    Wang, Yiting
    Wang, Li
    REVIEWS IN ANALYTICAL CHEMISTRY, 2022, 41 (01) : 189 - 197
  • [29] Non-enzymatic electrochemical sensor based on ZnO nanoparticles/porous graphene for the detection of hypoxanthine in pork meat
    Le, N. T. H.
    Viet, N. X.
    Anh, N. V.
    Bach, T. N.
    Thu, P. T.
    Ngoc, N. T.
    Manh, D. H.
    Ky, V. H.
    Lam, V. D.
    Kodelov, V.
    Von Gratowski, S.
    Binh, N. H.
    Anh, T. X.
    AIP ADVANCES, 2024, 14 (02)
  • [30] Nickel-functionalized reduced graphene oxide with polyaniline for non-enzymatic glucose sensing
    Bing Zhang
    Yu He
    Bingqian Liu
    Dianping Tang
    Microchimica Acta, 2015, 182 : 625 - 631