Analytical properties of the GEM Premier 3000 analyzer evaluated

被引:0
|
作者
Vukelic, Nada [1 ]
Futac, Daljia Papic [1 ]
Topic, Elizabeta [1 ]
机构
[1] Univ Zagreb, Sestre Milosrdnice Univ Hosp, Univ Dept Chem, HR-10000 Zagreb, Croatia
关键词
point of care testing; acid-base balance parameters; electrolytes; metabolites;
D O I
暂无
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Introduction: The development of sensor technology has led to the advent of analyzers for fast and simple determination of analyte concentration in whole blood samples that can be performed in a laboratory and as point of care testing (POCT). POCT analyzers are generally put in at intensive care units to enable rapid test results and earliest possible therapy introduction. Aim: To evaluate analytical properties of the GEM Premier 3000 analyzer and compatibility of the results obtained by use of this analyzer with those reported from analyzers used in central laboratory before the GEM Premier 3000 POCT analyzer fitting and placing in operation at Intensive Care Unit, University Department of Surgery. Material and methods: Analytical properties of the analyzer were evaluated by determination of within-run imprecision, between-run imprecision, inaccuracy, and comparative determination of analyte concentrations in patient samples on the study analyzer and the analyzers used for the respective analytes at central laboratory as reference analyzers. The study was performed in accordance with ECCLS recommendations. Results: Satisfactory results were recorded on within-run imprecision for all study analytes (CV:<= 3.46%), and on between-run imprecision for all analytes (CV <= 4.65%) except for lactate (Level 2, CV = 9.35%; Level 3, CV =5.55%). Inaccuracy evaluation yielded satisfactory results for all study analytes (R <= 4.53%) except for lactate (Level 1, R = 13.59%; Level 2, R = -11.00%; Level 3, R = 10.00%). Correlation coefficients were within range 0.9727-0.9920, except for sodium (r = 0.9207) and showed high correlation of all analyte concentrations determined in patient samples on the study analyzerand reference analyzers. Passing Bablok regression analysis also indicated a very high compatibility of analyte concentrations measured in patient samples by use of the study analyzer and reference analyzers. Conclusion: Results of analyte concentration determination in patient samples obtained by use of the study analyzer were compatible with those produced by reference analyzers at central laboratory. The GEM Premier 3000 analyzer has proved to be simple to operate, while automated and independent quality control performed after each individual sample and automated error elimination ensures safe work and reliable test results.d
引用
收藏
页码:231 / 241
页数:11
相关论文
共 50 条
  • [41] Limitations and opportunities of whole blood bilirubin measurements by GEM premier 4000®
    Li Wang
    Arianne Y. K. Albert
    Benjamin Jung
    Keyvan Hadad
    Martha E. Lyon
    Melanie Basso
    BMC Pediatrics, 17
  • [42] Limitations and opportunities of whole blood bilirubin measurements by GEM premier 4000®
    Wang, Li
    Albert, Arianne Y. K.
    Jung, Benjamin
    Hadad, Keyvan
    Lyon, Martha E.
    Basso, Melanie
    BMC PEDIATRICS, 2017, 17
  • [43] Reliability analysis of GEM (R) Premier (TM) technology: a multicenter study
    Faggiano, Francesco
    Franchin, Tiziana
    Ritrovato, Matteo
    Derrico, Pietro
    EMERGENCY CARE JOURNAL, 2015, 11 (02) : 23 - 25
  • [44] Analyst - the home of premier fundamental analytical science
    Graham, Duncan
    ANALYST, 2015, 140 (01) : 16 - 17
  • [45] THE EPOS AUTOMATED SELECTIVE CHEMISTRY ANALYZER EVALUATED
    MOSES, GC
    LIGHTLE, GO
    TUCKERMAN, JF
    HENDERSON, AR
    CLINICAL CHEMISTRY, 1986, 32 (01) : 165 - 169
  • [46] THE THEOPHYLLINE METHOD OF THE ABBOTT VISION ANALYZER EVALUATED
    CHAN, KM
    KOENIG, J
    WALTON, KG
    FRANCOEUR, TA
    LAU, BWC
    LADENSON, JH
    CLINICAL CHEMISTRY, 1987, 33 (01) : 130 - 132
  • [47] MEASUREMENT OF BLOOD CHOLESTEROL WITH THE REFLOTRON ANALYZER EVALUATED
    RASTAM, L
    ADMIRE, JB
    FRANTZ, ID
    HELLERSTEDT, W
    HUNNINGHAKE, DM
    KUBA, K
    LUEPKER, RV
    CLINICAL CHEMISTRY, 1988, 34 (02) : 426 - 426
  • [48] Arizona instrument's computrac 3000 moisture analyzer
    Polymer News, 2000, 25 (06):
  • [49] ENZYMATIC DETERMINATION OF TRIGLYCERIDES WITH A SYSTEM OLLI 3000 ANALYZER
    PUUKKA, R
    JOKELA, H
    PUUKKA, M
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1978, 38 (02): : 189 - 192
  • [50] Sulfhemoglobin dtetecion and correction to CO-Oximetry measurements on GEM premier 4000
    Pamidi, P.
    Mansouri, S.
    DeAbreu, M.
    Kim, D.
    CLINICAL CHEMISTRY, 2007, 53 (06) : A221 - A221