Analytical properties of the GEM Premier 3000 analyzer evaluated

被引:0
|
作者
Vukelic, Nada [1 ]
Futac, Daljia Papic [1 ]
Topic, Elizabeta [1 ]
机构
[1] Univ Zagreb, Sestre Milosrdnice Univ Hosp, Univ Dept Chem, HR-10000 Zagreb, Croatia
关键词
point of care testing; acid-base balance parameters; electrolytes; metabolites;
D O I
暂无
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Introduction: The development of sensor technology has led to the advent of analyzers for fast and simple determination of analyte concentration in whole blood samples that can be performed in a laboratory and as point of care testing (POCT). POCT analyzers are generally put in at intensive care units to enable rapid test results and earliest possible therapy introduction. Aim: To evaluate analytical properties of the GEM Premier 3000 analyzer and compatibility of the results obtained by use of this analyzer with those reported from analyzers used in central laboratory before the GEM Premier 3000 POCT analyzer fitting and placing in operation at Intensive Care Unit, University Department of Surgery. Material and methods: Analytical properties of the analyzer were evaluated by determination of within-run imprecision, between-run imprecision, inaccuracy, and comparative determination of analyte concentrations in patient samples on the study analyzer and the analyzers used for the respective analytes at central laboratory as reference analyzers. The study was performed in accordance with ECCLS recommendations. Results: Satisfactory results were recorded on within-run imprecision for all study analytes (CV:<= 3.46%), and on between-run imprecision for all analytes (CV <= 4.65%) except for lactate (Level 2, CV = 9.35%; Level 3, CV =5.55%). Inaccuracy evaluation yielded satisfactory results for all study analytes (R <= 4.53%) except for lactate (Level 1, R = 13.59%; Level 2, R = -11.00%; Level 3, R = 10.00%). Correlation coefficients were within range 0.9727-0.9920, except for sodium (r = 0.9207) and showed high correlation of all analyte concentrations determined in patient samples on the study analyzerand reference analyzers. Passing Bablok regression analysis also indicated a very high compatibility of analyte concentrations measured in patient samples by use of the study analyzer and reference analyzers. Conclusion: Results of analyte concentration determination in patient samples obtained by use of the study analyzer were compatible with those produced by reference analyzers at central laboratory. The GEM Premier 3000 analyzer has proved to be simple to operate, while automated and independent quality control performed after each individual sample and automated error elimination ensures safe work and reliable test results.d
引用
收藏
页码:231 / 241
页数:11
相关论文
共 50 条
  • [31] GEM Premier 3000 cartridge designed for point-of-care blood gas and electrolyte analysis: performance with bench-top-analyzers.
    Sridharan, R
    Frayne, L
    CLINICAL CHEMISTRY, 2000, 46 (06) : A56 - A56
  • [32] Evaluation of the GEM® Premier™ 4000:: a compact blood gas CO-Oximeter and electrolyte analyzer for point-of-care and laboratory testing
    Beneteau-Burnat, Benedicte
    Pernet, Pascal
    Pilon, Antoine
    Latour, Damien
    Goujon, Stephanie
    Feuillu, Alain
    Vaubourdolle, Michel
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2008, 46 (02) : 271 - 279
  • [33] THE EASY 6160 ANALYZER EVALUATED
    FRANCK, PFH
    HARFF, GA
    SOUVERIJN, JHM
    CLINICAL CHEMISTRY, 1988, 34 (12) : 2577 - 2578
  • [34] 利用IQM数据对GEM premier 3000血气分析仪再激活试剂包进行性能评估
    肖光军
    刘艳婷
    国际检验医学杂志, 2017, 38 (06) : 850 - 852
  • [35] Evaluation of the Analytical Properties of the Diagon CoagXL Coagulation Analyzer
    Koc, Hacer
    Yildiz, Zeynep
    Hurmeydan, Ozlem
    Madenci, Ozlem C.
    Yucel, Nihal
    Orcun, Asuman
    CLINICAL LABORATORY, 2019, 65 (06) : 975 - 981
  • [36] Effects of pre-analytical handling on selected canine hematological parameters evaluated by automatic analyzer
    Athanasiou, Labrini Vasileiou
    Polizopoulou, Zoe
    Kalafati, Maria Rafaela
    Ntararas, George
    Kontos, Vasileios
    VETERINARY RESEARCH FORUM, 2016, 7 (04) : 281 - 285
  • [37] Analytical Performance Evaluation of Automated Coagulation Analyzer CP3000 for Routine and Special Coagulation Assays
    Kim, Bohyun
    Seo, Min Sook
    Park, Rojin
    ANNALS OF CLINICAL AND LABORATORY SCIENCE, 2021, 51 (01): : 112 - 119
  • [38] An Evaluation of a Point-of-Care GEM Premier ChemSTAT Analyzer in an Emergency Department: Prevention of Contrast-Induced Nephropathy and Optimization of Patient Flow
    Brailova, Marina
    Audin, Marie
    Raconnat, Julien
    Bouillon-Minois, Jean-Baptiste
    Schmidt, Jeannot
    Pereira, Bruno
    Bouvier, Damien
    Sapin, Vincent
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (23)
  • [39] GLASS LUSTER EVALUATED WITH SURFACE ANALYZER
    不详
    CERAMIC AGE, 1966, 82 (03): : 50 - &
  • [40] Evaluation of the CP3000 coagulation analyzer
    Stroobants, A. K.
    Bakker, B.
    van den Dool, E. J.
    Hoffmann, J.
    Heckman, M.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2016, 14 : 23 - 23