Analytical properties of the GEM Premier 3000 analyzer evaluated

被引:0
|
作者
Vukelic, Nada [1 ]
Futac, Daljia Papic [1 ]
Topic, Elizabeta [1 ]
机构
[1] Univ Zagreb, Sestre Milosrdnice Univ Hosp, Univ Dept Chem, HR-10000 Zagreb, Croatia
关键词
point of care testing; acid-base balance parameters; electrolytes; metabolites;
D O I
暂无
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Introduction: The development of sensor technology has led to the advent of analyzers for fast and simple determination of analyte concentration in whole blood samples that can be performed in a laboratory and as point of care testing (POCT). POCT analyzers are generally put in at intensive care units to enable rapid test results and earliest possible therapy introduction. Aim: To evaluate analytical properties of the GEM Premier 3000 analyzer and compatibility of the results obtained by use of this analyzer with those reported from analyzers used in central laboratory before the GEM Premier 3000 POCT analyzer fitting and placing in operation at Intensive Care Unit, University Department of Surgery. Material and methods: Analytical properties of the analyzer were evaluated by determination of within-run imprecision, between-run imprecision, inaccuracy, and comparative determination of analyte concentrations in patient samples on the study analyzer and the analyzers used for the respective analytes at central laboratory as reference analyzers. The study was performed in accordance with ECCLS recommendations. Results: Satisfactory results were recorded on within-run imprecision for all study analytes (CV:<= 3.46%), and on between-run imprecision for all analytes (CV <= 4.65%) except for lactate (Level 2, CV = 9.35%; Level 3, CV =5.55%). Inaccuracy evaluation yielded satisfactory results for all study analytes (R <= 4.53%) except for lactate (Level 1, R = 13.59%; Level 2, R = -11.00%; Level 3, R = 10.00%). Correlation coefficients were within range 0.9727-0.9920, except for sodium (r = 0.9207) and showed high correlation of all analyte concentrations determined in patient samples on the study analyzerand reference analyzers. Passing Bablok regression analysis also indicated a very high compatibility of analyte concentrations measured in patient samples by use of the study analyzer and reference analyzers. Conclusion: Results of analyte concentration determination in patient samples obtained by use of the study analyzer were compatible with those produced by reference analyzers at central laboratory. The GEM Premier 3000 analyzer has proved to be simple to operate, while automated and independent quality control performed after each individual sample and automated error elimination ensures safe work and reliable test results.d
引用
收藏
页码:231 / 241
页数:11
相关论文
共 50 条
  • [1] Evaluation of the blood gas analyzer GEM® PREMIER 3000
    Bénéteau-Burnat, B
    Bocque, MC
    Lorin, A
    Martin, C
    Vaubourdolle, M
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2004, 42 (01) : 96 - 101
  • [2] Analitical performance of the Blood Gas Analyzer:: IL GEM® Premier 3000
    Ilic, M
    Stankovic, S
    Majkic-Singh, N
    CLINICAL CHEMISTRY, 2005, 51 : A32 - A32
  • [3] PERFORMANCE OF GEM PREMIER BLOOD-GAS ELECTROLYTE ANALYZER EVALUATED
    JACOBS, E
    NOWAKOWSKI, M
    COLMAN, N
    CLINICAL CHEMISTRY, 1993, 39 (09) : 1890 - 1893
  • [4] Intelligent quality management in the GEM Premier 3000 critical care analyzer.
    Mansouri, S
    Fallen, K
    Eames, P
    CLINICAL CHEMISTRY, 2002, 48 (06) : A6 - A7
  • [5] Analytical performance evaluation of the new GEM® Premier™ 5000 analyzer in comparison to the GEM® Premier™ 4000 and the RapidPoint® 405 systems
    Mion, Monica Maria
    Bragato, Giada
    Zaninotto, Martina
    Alessandroni, Jhessica
    Bernardini, Sergio
    Plebani, Mario
    CLINICA CHIMICA ACTA, 2018, 486 : 313 - 319
  • [6] Integration of glucose and lactate sensors to the GEM Premier 3000 blood gas: Electrolyte analyzer.
    Xu, C
    Shin, M
    Crim, A
    Mansouri, S
    CLINICAL CHEMISTRY, 2000, 46 (06) : A12 - A12
  • [7] Performance evaluation. of the IL GEM premier 3000 analyzer with intelligent quality management.
    Mansouri, S
    CLINICAL CHEMISTRY, 2003, 49 (06) : A150 - A150
  • [8] Performance evaluation of a new high volume cartridge for the GEM Premier, 3000 critical care analyzer.
    Ancy, JJ
    D'Orazio, P
    Alexander, A
    Hanford, H
    CLINICAL CHEMISTRY, 2002, 48 (06) : A152 - A152
  • [9] Analytical Performance Evaluation of the New GEM® Premier™ 5000 in Comparison to the Epoc® Blood Gas Analyzer in Horses
    Sandersen, Charlotte
    Dmitrovic, Petra
    Dupont, Julien
    Cesarini, Carla
    Guyot, Hugues
    Serteyn, Didier
    Kirsch, Katharina
    VETERINARY SCIENCES, 2023, 10 (02)
  • [10] Clinical evaluation of the GEM® premier 4000 critical care analyzer
    Blanco, P.
    Romero, C.
    Rodriguez, C.
    Molina, M. J.
    Mantecas, J.
    Cervera, I.
    CLINICAL CHEMISTRY, 2007, 53 (06) : A177 - A177