Prognosis after aortic valve replacement with the Carpentier-Edwards pericardial valve: Use of microsimulation

被引:16
|
作者
Puvimanasinghe, JPA
Takkenberg, JJM
Eijkemans, MJC
Steyerber, EW
van Herwerden, LA
Grunkemeier, GL
Habbema, JDF
Bogers, AJJC
机构
[1] Erasmus MC, Dept Cardiothorac Surg, NL-3000 CA Rotterdam, Netherlands
[2] Erasmus MC, Dept Publ Hlth, NL-3000 CA Rotterdam, Netherlands
[3] Providence Hlth Syst, Portland, OR USA
来源
ANNALS OF THORACIC SURGERY | 2005年 / 80卷 / 03期
关键词
D O I
10.1016/j.athoracsur.2005.03.064
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. The second-generation Carpentier-Edwards pericardial valve (Edwards Lifesciences LLC, Irvine, CA) is widely used for aortic valve replacement. However, knowledge on the long-term outcomes of patients after valve implantation is incomplete. We used microsimulation to calculate the long-term outcome of any given patient after aortic valve replacement with the Carpentier-Edwards pericardial valve. Methods. A meta-analysis of 8 reports on aortic valve replacement with the Carpentier-Edwards pericardial valve (2,685 patients; 12,250 patient years) was used to estimate the hazards of valve-related events other than structural valvular deterioration. Structural valvular deterioration was described by age-dependent Weibull curves calculated from 18-year follow-up, premarket approval, Carpentier-Edwards pericardial primary data. These estimates provided the input data for the parameters of the microsimulation model, which was then used to calculate the outcomes of patients of different ages after valve implantation. The model estimates of survival were validated using two external data sets. Results. The Weibull analysis estimated a median time to reoperation for structural valvular deterioration ranging from 18.1 years for a 55-year-old male to 23.2 years for a 75-year-old male. For a 65-year-old male, microsimulation calculated a life expectancy and event-free life expectancy of 10.8 and 9.1 years, respectively. The lifetime risk of at least one valve-related event was 38% and that of reoperation due to structural valvular deterioration 17%, respectively, for this patient. The model estimates of survival showed good agreement with external data. Conclusions. Microsimulation provides detailed insight into the long-term prognosis of patients after aortic valve replacement. The Carpentier-Edwards pericardial valve performs satisfactorily and offers a low lifetime risk of reoperation due to structural valvular deterioration, especially for elderly patients requiring aortic valve replacement.
引用
收藏
页码:825 / 831
页数:7
相关论文
共 50 条
  • [31] Triple-valve treatment for prosthetic valve endocarditis occurring 20 years after implantation of a Carpentier-Edwards pericardial bioprosthesis in the aortic valve
    Hisata Y.
    Hazama S.
    Izumi K.
    Eishi K.
    General Thoracic and Cardiovascular Surgery, 2008, 56 (12) : 595 - 598
  • [32] Eight-year outcomes of aortic valve replacement with the Carpentier-Edwards PERIMOUNT Magna Ease valve
    Tsui, Steven
    Rosenbloom, Michael
    Abel, James
    Swanson, Jeffrey
    Haverich, Axel
    Zacharias, Joseph
    Schorlemmer, Gilbert
    Cohen, Gideon
    Moulton, Michael
    Lange, Ruediger
    JOURNAL OF CARDIAC SURGERY, 2022, 37 (12) : 4999 - 5010
  • [33] Influence of coronary artery disease and functional class an long term survival after aortic valve replacement with the Carpentier-Edwards pericardial bioprosthesis
    Do, QB
    Pellerin, M
    Cartler, R
    Hebert, Y
    Page, P
    Perrault, LP
    Pelletier, LC
    CIRCULATION, 1999, 100 (18) : 459 - 459
  • [34] RISK OF THROMBOEMBOLISM EARLY FOLLOWING AORTIC-VALVE REPLACEMENT WITH THE CARPENTIER-EDWARDS BIOPROSTHESIS
    ORSZULAK, TA
    SCHAFF, HV
    MULLANY, CJ
    PUGA, FJ
    DANIELSON, GK
    CIRCULATION, 1992, 86 (04) : 497 - 497
  • [35] THE INFLUENCE OF AGE ON VALVE RELATED EVENTS WITH CARPENTIER-EDWARDS PERICARDIAL VALVES
    AUPART, MR
    DREYFUS, XB
    MEURISSE, YA
    ROUCHET, SC
    SIRINELLI, AL
    MAY, MA
    MARCHAND, MA
    JOURNAL OF CARDIOVASCULAR SURGERY, 1995, 36 (04): : 297 - 302
  • [36] Immediate structural valve deterioration of 27-mm Carpentier-Edwards aortic pericardial bioprosthesis
    Fleisher, AG
    Lafaro, RJ
    Moggio, RA
    ANNALS OF THORACIC SURGERY, 2004, 77 (04): : 1443 - 1445
  • [37] Twelve-year experience with the Carpentier-Edwards pericardial aortic valve at a single Japanese center
    Arinaga, Koichi
    Fukunaga, Shuji
    Tomoeda, Hiroshi
    Hori, Hidetsugu
    Ueda, Tomohiro
    Mori, Ryusuke
    Aoyagi, Shigeaki
    JOURNAL OF ARTIFICIAL ORGANS, 2011, 14 (03) : 209 - 214
  • [38] Long-Term Outcome of the Carpentier-Edwards Pericardial Valve in the Aortic Position in Japanese Patients
    Minakata, Kenji
    Tanaka, Shiro
    Okawa, Yohei
    Shimamoto, Mitsuomi
    Kaneko, Tatsuo
    Takahara, Yoshiharu
    Yaku, Hitoshi
    Yamanaka, Kazuo
    Usui, Akihiko
    Tamura, Nobushige
    Sakata, Ryuzo
    CIRCULATION JOURNAL, 2014, 78 (04) : 882 - 889
  • [39] Carpentier-Edwards aortic pericardial bioprosthetic valve as a valid control in preclinical in vivo ovine studies
    Harvey, Laura
    Bianco, Richard
    Lahti, Matthew
    Carney, John
    Zhang, Lindsey
    Robinson, Nicholas
    EUROPEAN JOURNAL OF PHARMACOLOGY, 2015, 759 : 192 - 199
  • [40] Influence of age on valve related events with Carpentier-Edwards pericardial bioprosthesis
    Aupart, M
    Babuty, D
    Neville, P
    Fauchier, L
    Sirinelli, A
    Marchand, M
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1997, 11 (05) : 929 - 934