Prognosis after aortic valve replacement with the Carpentier-Edwards pericardial valve: Use of microsimulation

被引:16
|
作者
Puvimanasinghe, JPA
Takkenberg, JJM
Eijkemans, MJC
Steyerber, EW
van Herwerden, LA
Grunkemeier, GL
Habbema, JDF
Bogers, AJJC
机构
[1] Erasmus MC, Dept Cardiothorac Surg, NL-3000 CA Rotterdam, Netherlands
[2] Erasmus MC, Dept Publ Hlth, NL-3000 CA Rotterdam, Netherlands
[3] Providence Hlth Syst, Portland, OR USA
来源
ANNALS OF THORACIC SURGERY | 2005年 / 80卷 / 03期
关键词
D O I
10.1016/j.athoracsur.2005.03.064
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. The second-generation Carpentier-Edwards pericardial valve (Edwards Lifesciences LLC, Irvine, CA) is widely used for aortic valve replacement. However, knowledge on the long-term outcomes of patients after valve implantation is incomplete. We used microsimulation to calculate the long-term outcome of any given patient after aortic valve replacement with the Carpentier-Edwards pericardial valve. Methods. A meta-analysis of 8 reports on aortic valve replacement with the Carpentier-Edwards pericardial valve (2,685 patients; 12,250 patient years) was used to estimate the hazards of valve-related events other than structural valvular deterioration. Structural valvular deterioration was described by age-dependent Weibull curves calculated from 18-year follow-up, premarket approval, Carpentier-Edwards pericardial primary data. These estimates provided the input data for the parameters of the microsimulation model, which was then used to calculate the outcomes of patients of different ages after valve implantation. The model estimates of survival were validated using two external data sets. Results. The Weibull analysis estimated a median time to reoperation for structural valvular deterioration ranging from 18.1 years for a 55-year-old male to 23.2 years for a 75-year-old male. For a 65-year-old male, microsimulation calculated a life expectancy and event-free life expectancy of 10.8 and 9.1 years, respectively. The lifetime risk of at least one valve-related event was 38% and that of reoperation due to structural valvular deterioration 17%, respectively, for this patient. The model estimates of survival showed good agreement with external data. Conclusions. Microsimulation provides detailed insight into the long-term prognosis of patients after aortic valve replacement. The Carpentier-Edwards pericardial valve performs satisfactorily and offers a low lifetime risk of reoperation due to structural valvular deterioration, especially for elderly patients requiring aortic valve replacement.
引用
收藏
页码:825 / 831
页数:7
相关论文
共 50 条
  • [21] Carpentier-Edwards pericardial valve in the aortic position: 25-years experience
    Jose Dalmau, Maria
    CIRUGIA CARDIOVASCULAR, 2014, 21 (01): : 67 - 68
  • [22] 20 years' durability of Carpentier-Edwards Perimount stented pericardial aortic valve
    Bergoend, E.
    Aupart, M. R.
    Mirza, A.
    Meurisse, Y. A.
    Sirinelli, A. L.
    Neville, P. H.
    Marchand, M. A.
    AORTIC ROOT SURGERY: THE BIOLOGICAL SOLUTION, 2010, : 441 - +
  • [23] LONG-TERM EVALUATION OF THE CARPENTIER-EDWARDS PERICARDIAL VALVE IN THE AORTIC POSITION
    PERIER, P
    MIHAILEANU, S
    FABIANI, JN
    DELOCHE, A
    CHAUVAUD, S
    JINDANI, A
    CARPENTIER, A
    JOURNAL OF CARDIAC SURGERY, 1991, 6 (04) : 589 - 594
  • [24] Carpentier-Edwards Pericardial Valve in the Aortic Position: 25-Years Experience
    Forcillo, Jessica
    Pellerin, Michel
    Perrault, Louis P.
    Cartier, Raymond
    Bouchar, Denis
    Demers, Philippe
    Carrier, Michel
    ANNALS OF THORACIC SURGERY, 2013, 96 (02): : 486 - 493
  • [25] COMPARISON OF ANTICOAGULATION REGIMENS AFTER CARPENTIER-EDWARDS AORTIC OR MITRAL-VALVE REPLACEMENT
    BLAIR, KL
    HATTON, AC
    WHITE, WD
    SMITH, LR
    LOWE, JE
    WOLFE, WG
    YOUNG, WG
    OLDHAM, HN
    DOUGLAS, JM
    GLOWER, DD
    CIRCULATION, 1994, 90 (05) : 214 - 219
  • [26] THE CARPENTIER-EDWARDS PERICARDIAL AORTIC-VALVE - 10-YEAR RESULTS
    COSGROVE, DM
    LYTLE, BW
    TAYLOR, PC
    CAMACHO, MT
    STEWART, RW
    MCCARTHY, PM
    MILLER, DP
    PIEDMONTE, MR
    LOOP, FD
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1995, 110 (03): : 651 - 662
  • [27] THE CARPENTIER-EDWARDS PERICARDIAL AORTIC-VALVE - INTERMEDIATE RESULTS IN 420 PATIENTS
    AUPART, M
    NEVILLE, P
    DREYFUS, X
    MEURISSE, Y
    SIRINELLI, A
    MARCHAND, M
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1994, 8 (05) : 277 - 280
  • [28] Mid-term comparative follow-up after aortic valve replacement with Carpentier-Edwards and Pericarbon pericardial prostheses
    Le Tourneau, T
    Savoye, C
    McFadden, EP
    Grandmougin, D
    Carton, HF
    Hennequin, JL
    Dubar, A
    Fayad, G
    Warembourg, H
    CIRCULATION, 1999, 100 (19) : 11 - 16
  • [29] COMPARISON OF ANTICOAGULATION REGIMENS AFTER STANDARD CARPENTIER-EDWARDS AORTIC OR MITRAL-VALVE REPLACEMENT
    BLAIR, KL
    HATTON, AC
    WHITE, WD
    SMITH, LR
    LOWE, JE
    WOLFE, WG
    YOUNG, WG
    OLDHAM, HN
    GLOWER, DD
    CIRCULATION, 1993, 88 (04) : 575 - 575
  • [30] Twelve-year experience with the 19 mm Carpentier-Edwards pericardial aortic valve
    Nakajima, H
    Aupart, MR
    Neville, PH
    Sirinelli, AL
    Meurisse, YA
    Marchand, MA
    JOURNAL OF HEART VALVE DISEASE, 1998, 7 (05): : 534 - 539