Determination of trace metoclopramide by anodic stripping voltammetry with nafion modified glassy carbon electrode

被引:50
|
作者
Wang, ZH [1 ]
Zhang, HZ [1 ]
Zhou, SP [1 ]
Dong, WJ [1 ]
机构
[1] Henan Normal Univ, Dept Chem, Xinxiang 453002, Peoples R China
关键词
metoclopramide; modified electrode; anodic stripping voltammetry;
D O I
10.1016/S0039-9140(00)00519-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel method is described for determination of metoclopramide (MCP) by second-derivative adsorptive anodic stripping voltammetry with a nafion-modified electrode. The stripping peak current is proportional to the concentration of MCP over the range 1.2 x 10(-9)-4.6 x 10(-7) M. The detection limit is 8.0 x 10(-11) M with 4-min accumulation. The method has been successfully applied to the determination of MCP in human serum. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1133 / 1138
页数:6
相关论文
共 50 条
  • [31] Adsorptive Stripping Voltammetry for Trace Determination of Quinalphos Employing Silicon Carbide Nanoparticles Modified Glassy Carbon Electrode
    Khare, Ninad G.
    Dar, Riyaz A.
    Srivastava, Ashwini K.
    ELECTROANALYSIS, 2015, 27 (02) : 503 - 509
  • [32] Application of a carbon nanotube modified electrode in anodic stripping voltammetry for determination of trace amounts of 6-benzylaminopurine
    Zhao, G
    Liu, KZ
    Lin, S
    Liang, J
    Guo, XY
    Zhang, ZJ
    MICROCHIMICA ACTA, 2003, 143 (04) : 255 - 260
  • [33] Application of a Carbon Nanotube Modified Electrode in Anodic Stripping Voltammetry for Determination of Trace Amounts of 6-Benzylaminopurine
    Ge Zhao
    Kuaizhi Liu
    Song Lin
    Ji Liang
    Xinyong Guo
    Zhijun Zhang
    Microchimica Acta, 2003, 143 : 255 - 260
  • [34] Determination of Trace Metals by Anodic Stripping Voltammetry Using a Carbon Nanotube Tower Electrode
    Guo, Xuefei
    Yun, Yeoheung
    Shanov, Vesselin N.
    Halsall, H. Brian
    Heineman, William R.
    ELECTROANALYSIS, 2011, 23 (05) : 1252 - 1259
  • [35] Determination of diquat at a Nafion film modified glassy carbon electrode using electrocatalytic voltammetry
    Lu, TW
    Sun, IW
    ELECTROANALYSIS, 2000, 12 (08) : 605 - 609
  • [36] Determination of copper by anodic stripping voltammetry on a glassy carbon electrode using a continuous flow system
    J. F. van Staden
    M. Matoetoe
    Fresenius' Journal of Analytical Chemistry, 1997, 357 : 624 - 628
  • [37] Determination of copper by anodic stripping voltammetry on a glassy carbon electrode using a continuous flow system
    vanStaden, JF
    Matoetoe, M
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 357 (06): : 624 - 628
  • [38] Trace analysis of lead at a Nafion-modified electrode using square-wave anodic stripping voltammetry
    Crowley, K
    Cassidy, J
    ELECTROANALYSIS, 2002, 14 (15-16) : 1077 - 1082
  • [39] Electrochemical behavior of lead(II) at poly(phenol red) modified glassy carbon electrode, and its trace determination by differential pulse anodic stripping voltammetry
    Yang, Gongjun
    Qu, Xilong
    Shen, Ming
    Wang, Chengyin
    Qu, Qishu
    Hu, Xiaoya
    MICROCHIMICA ACTA, 2008, 160 (1-2) : 275 - 281
  • [40] Electrochemical behavior of lead(II) at poly(phenol red) modified glassy carbon electrode, and its trace determination by differential pulse anodic stripping voltammetry
    Gongjun Yang
    Xilong Qu
    Ming Shen
    Chengyin Wang
    Qishu Qu
    Xiaoya Hu
    Microchimica Acta, 2008, 160 : 275 - 281