Trace analysis of lead at a Nafion-modified electrode using square-wave anodic stripping voltammetry

被引:0
|
作者
Crowley, K [1 ]
Cassidy, J [1 ]
机构
[1] Dublin Inst Technol, Sch Chem, Dublin 8, Ireland
关键词
Nafion-modified electrode; square-wave anodic stripping voltammetry; lead; trace analysis;
D O I
10.1002/1521-4109(200208)14:15/16<1077::AID-ELAN1077>3.0.CO;2-3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
ASV using square-wave voltammetry was used with Nafion-coated glassy carbon electrodes for lead analysis and it was found that square-wave frequencies greater than 100 Hz could be employed satisfactorily for trace lead detection. Peak current increases with frequencies up to 1000 Hz at step potentials of up to 10 mV, though not linearly. However, the enhanced sensitivity allows the analysis of low levels of lead with concentrations down to 1 ppb detectable. This technique gave a value of 15.0 +/- 1.3 ppb lead in a diluted certified reference material with lead concentration of 14.7 ppb.
引用
收藏
页码:1077 / 1082
页数:6
相关论文
共 50 条
  • [1] Determination of trace lead by square-wave anodic stripping voltammetry
    Wang, Mingliang
    Li, Minjing
    Yejin Fenxi/Metallurgical Analysis, 2000, 20 (01): : 42 - 44
  • [2] Square-wave Amplitude Effect in Cathodic and Anodic Stripping Square-wave Voltammetry
    Guziejewski, Dariusz
    ELECTROANALYSIS, 2019, 31 (02) : 231 - 238
  • [3] Square-wave anodic stripping voltammetric determination of thallium(I) at a Nafion mercury film modified electrode
    Lu, TH
    Yang, HY
    Sun, IW
    TALANTA, 1999, 49 (01) : 59 - 68
  • [4] Assessment of Lead and Cadmium in Canned Foods by Square-Wave Anodic Stripping Voltammetry
    Ghanjaoui, Mohammed El Amine
    Srij, Mohammed
    El Rhazi, Mama
    ANALYTICAL LETTERS, 2009, 42 (09) : 1294 - 1309
  • [5] Determination of Caffeine Using a Simple Graphite Pencil Electrode with Square-Wave Anodic Stripping Voltammetry
    Suw Young Ly
    Young Sam Jung
    Myung Hoon Kim
    In kwon Han
    Woon Won Jung
    Hyun Sook Kim
    Microchimica Acta, 2004, 146 : 207 - 213
  • [6] Determination of caffeine using a simple graphite pencil electrode with square-wave anodic stripping voltammetry
    Ly, SY
    Jung, YS
    Kim, MH
    Han, IK
    Jung, WW
    Kim, HS
    MICROCHIMICA ACTA, 2004, 146 (3-4) : 207 - 213
  • [7] Determination of trace metoclopramide by anodic stripping voltammetry with nafion modified glassy carbon electrode
    Wang, ZH
    Zhang, HZ
    Zhou, SP
    Dong, WJ
    TALANTA, 2001, 53 (06) : 1133 - 1138
  • [8] Determination of trace manganese by square-wave stripping voltammetry
    Wang, Shujie
    Ye, Baoxian
    ELECTROANALYSIS, 2008, 20 (09) : 984 - 988
  • [9] SQUARE-WAVE ANODIC-STRIPPING VOLTAMMETRY AT THE MERCURY FILM ELECTRODE - THEORETICAL TREATMENT
    KOUNAVES, SP
    ODEA, JJ
    CHANDRESEKHAR, P
    OSTERYOUNG, J
    ANALYTICAL CHEMISTRY, 1987, 59 (03) : 386 - 389
  • [10] Kinetic speciation of lead and cadmium in freshwaters using square-wave anodic stripping voltammetry with a thin mercury film rotating disk electrode
    Lam, MT
    Murimboh, J
    Hassan, NM
    Chakrabarti, CL
    ELECTROANALYSIS, 2001, 13 (02) : 94 - 99