Research of the absorbance detection and fluorescence detection for multifunctional nutrition analyzer

被引:0
|
作者
Ni, Zhengyuan [1 ,2 ]
Yan, Huimin [1 ,2 ]
Ni, Xuxiang [1 ,2 ]
Zhang, Xiuda [1 ,2 ]
机构
[1] Zhejiang Univ, State Key Lab Modern Opt Instrument, Hangzhou 310027, Zhejiang, Peoples R China
[2] Zhejiang Univ, Natl Engn & Technol Res Ctr Opt Instrument, Hangzhou 310027, Zhejiang, Peoples R China
来源
基金
国家高技术研究发展计划(863计划);
关键词
Multifunction; Absorbance detection; Fluorescence detection; Photon counter;
D O I
10.1117/12.2285019
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The research of the multifunctional analyzer which integrates absorbance detection, fluorescence detection, time-resolved fluorescence detection, biochemical luminescence detection methods, can make efficient detection and analysis for a variety of human body nutrients. This article focuses on the absorbance detection and fluorescence detection system. The two systems are modular in design and controlled by embedded system, to achieve automatic measurement according to user settings. In the optical path design, the application of confocal design can improve the optical signal acquisition capability, and reduce the interference. A photon counter is used for detection, and a high performance counter module is designed to measure the output of photon counter. In the experiment, we use neutral density filters and potassium dichromate solution to test the absorbance detection system, and use fluorescein isothiocyanate(FITC) for fluorescence detection system performance test. The experimental results show that the absorbance detection system has a detection range of 0 similar to 4OD, and has good linearity in the detection range, while the fluorescence detection system has a high sensitivity of 1pmol/L concentration.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Research on high precision detection of seawater absorbance
    海水吸光度特性高精度检测研究
    1600, Chinese Society of Astronautics (49):
  • [2] A bent Laue analyzer for fluorescence EXAFS detection
    Zhong, Z
    Chapman, D
    Bunker, B
    Bunker, G
    Fischetti, R
    Segre, C
    JOURNAL OF SYNCHROTRON RADIATION, 1999, 6 : 212 - 214
  • [3] A bent Laue analyzer for fluorescence EXAFS detection
    Zhong, Zhong
    Chapman, Dean
    Bunker, Bruce
    Bunker, Grant
    Fischetti, Robert
    Segre, Carlo
    Journal of Synchrotron Radiation, 1999, 6 (03): : 212 - 214
  • [4] Miniaturized detection system for fluorescence and absorbance measurements in chromatographic applications
    Van Overmeire, Sara
    Ottevaere, Heidi
    Desmet, Gert
    Thienpont, Hugo
    IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 2008, 14 (01) : 140 - 150
  • [5] Total internal reflection-based module for fluorescence and absorbance detection
    Verschooten, Tom
    Ottevaere, Heidi
    Vervaeke, Michael
    Van Erps, Juergen
    Thienpont, Hugo
    JOURNAL OF MICRO-NANOLITHOGRAPHY MEMS AND MOEMS, 2014, 13 (03):
  • [6] DETECTION OF GAS-CHROMATOGRAPHY ELUATES BY SIMULTANEOUS ABSORBANCE AND FLUORESCENCE MEASUREMENTS
    ADAMS, AK
    VANENGELEN, DL
    THOMAS, LC
    JOURNAL OF CHROMATOGRAPHY, 1984, 303 (02): : 341 - 349
  • [7] Simultaneous absorbance, fluorescence and refractive index (SAFRIN) detection for Micro LC
    Abbas, AA
    Shelly, DC
    ANALYTICA CHIMICA ACTA, 1999, 397 (1-3) : 191 - 205
  • [8] DETERMINATION OF PORPHYRINS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY - FLUORESCENCE DETECTION COMPARED TO ABSORBANCE DETECTION
    SAGEN, E
    ROMSLO, I
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1985, 45 (04): : 309 - 314
  • [9] A bent Laue analyzer detection system for dilute fluorescence XAFS
    Karanfil, C
    Zhong, Z
    Chapman, LD
    Fischetti, R
    Bunker, GB
    Segre, CU
    Bunker, BA
    SYNCHROTRON RADIATION INSTRUMENTATION, 2000, 521 : 178 - 182
  • [10] AUTOMATED ENZYME ASSAYS BY USE OF A CENTRIFUGAL ANALYZER WITH FLUORESCENCE DETECTION
    PEARSON, KW
    SMITH, RE
    MITCHELL, AR
    BISSEL, ER
    CLINICAL CHEMISTRY, 1981, 27 (02) : 256 - 262