A bent Laue analyzer for fluorescence EXAFS detection

被引:44
|
作者
Zhong, Z [1 ]
Chapman, D
Bunker, B
Bunker, G
Fischetti, R
Segre, C
机构
[1] Brookhaven Natl Lab, NSLS, Upton, NY 11973 USA
[2] IIT, CSRRI, Chicago, IL 60616 USA
[3] Univ Notre Dame, Dept Phys, Notre Dame, IN 46556 USA
[4] IIT, BioCAT Project, Chicago, IL 60616 USA
[5] IIT, BCPS Dept, Chicago, IL 60616 USA
关键词
crystal analyzer; fluorescence detector; bent crystal;
D O I
10.1107/S0909049599002022
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
An analyzer for detection of fluorescence radiation was developed for fluorescence XAFS of dilute samples at energies above 13 keV. The analyzer is a bent Laue crystal of logarithmic spiral shape. The K fluorescence lines can be collected with a large solid angle and moderate reflectivity using the asymmetric [111] reflection of silicon crystals of 200 micron thick. Tuning of the analyzer diffraction energies for different samples can be made with one adjustment. Experiment was performed at the APS BioCAT ID beamline using a silicon crystal bent to an average radius of 200 mm to diffract silver fluorescence x-rays. The crystal (35 mm by 120 mm active area) covers a solid angle of 0.1 SR of the sample fluorescence. The measured reflectivity was 10%.
引用
收藏
页码:212 / 214
页数:3
相关论文
共 50 条
  • [1] A bent Laue analyzer for fluorescence EXAFS detection
    Zhong, Zhong
    Chapman, Dean
    Bunker, Bruce
    Bunker, Grant
    Fischetti, Robert
    Segre, Carlo
    Journal of Synchrotron Radiation, 1999, 6 (03): : 212 - 214
  • [2] A bent Laue analyzer detection system for dilute fluorescence XAFS
    Karanfil, C
    Zhong, Z
    Chapman, LD
    Fischetti, R
    Bunker, GB
    Segre, CU
    Bunker, BA
    SYNCHROTRON RADIATION INSTRUMENTATION, 2000, 521 : 178 - 182
  • [3] LABORATORY EXAFS BY FLUORESCENCE DETECTION
    TOHJI, K
    MIZUSHIMA, T
    UDAGAWA, Y
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1990, 29 (10): : 2171 - 2175
  • [4] FLUORESCENCE DETECTION OF SURFACE EXAFS
    HEALD, SM
    KELLER, E
    STERN, EA
    PHYSICS LETTERS A, 1984, 103 (03) : 155 - 158
  • [5] Research on a logarithmically bent Laue crystal analyzer for X-ray monochromatic backlight imaging
    Wu, Yufen
    Xiao, Shali
    Lu, Jian
    Liu, Lifeng
    Yang, Qingguo
    Huang, Xianbin
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2013, 84 (07):
  • [6] DETECTION SYSTEMS FOR FLUORESCENCE EXAFS MEASUREMENT
    BAINES, J
    GARNER, CD
    HASNAIN, SS
    MORRELL, C
    JOURNAL DE PHYSIQUE, 1986, 47 (C-8): : 163 - 166
  • [7] Cylindrically bent Laue analyzer in an X-ray Raman/emission spectrometer: performance tests and a comparison with spherically bent Bragg analyzers
    Hiraoka, Nozomu
    JOURNAL OF SYNCHROTRON RADIATION, 2025, 32 : 109 - 117
  • [8] Characterization of bent crystals for Laue lenses
    Liccardo, V.
    Virgilli, E.
    Frontera, F.
    Valsan, V.
    SPACE TELESCOPES AND INSTRUMENTATION 2012: ULTRAVIOLET TO GAMMA RAY, 2012, 8443
  • [9] PERFORMANCE EVALUATION OF A BENT LAUE MONOCHROMATOR
    SUORTTI, P
    THOMLINSON, W
    CHAPMAN, D
    GMUR, N
    GREENE, R
    LAZARZ, N
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 297 (1-2): : 268 - 274
  • [10] ION CHAMBERS FOR FLUORESCENCE AND LABORATORY EXAFS DETECTION
    STERN, EA
    ELAM, WT
    BUNKER, BA
    LU, K
    HEALD, SM
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1982, 195 (1-2): : 345 - 346