PERFORMANCE EVALUATION OF A BENT LAUE MONOCHROMATOR

被引:17
|
作者
SUORTTI, P [1 ]
THOMLINSON, W [1 ]
CHAPMAN, D [1 ]
GMUR, N [1 ]
GREENE, R [1 ]
LAZARZ, N [1 ]
机构
[1] BROOKHAVEN NATL LAB,NATL SYNCHROTRON LIGHT SOURCE,UPTON,NY 11973
基金
芬兰科学院;
关键词
D O I
10.1016/0168-9002(90)91375-L
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A prototype focusing Laue geometry dual-energy monochromator, designed for human coronary angiography, has been tested at the National Synchrotron Light Source. The monochromatic photon beams from (111) reflections from two cylindrically bent [100] wafers of silicon were adjusted such that the energy of one of the beams was just above the K edge of iodine and the other beam's energy was just below the edge. Focusing of the beams by the bent crystals was measured with photographic film. An incident beam 4 mm high was focused to a line less than 0.3 mm high at a distance of 3 m. The monochromatic flux was determined by measuring the integrated intensities of a standard Mo powder sample and was in excellent agreement with the theoretical estimates. The reflectivity of the crystals was enhanced due to bending by an order of magnitude over the dynamical value.
引用
收藏
页码:268 / 274
页数:7
相关论文
共 50 条
  • [1] A BENT LAUE CRYSTAL MONOCHROMATOR FOR ANGIOGRAPHY AT THE NSLS
    SUORTTI, P
    THOMLINSON, W
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 269 (03): : 639 - 648
  • [2] BENT LAUE CRYSTAL MONOCHROMATOR FOR ANGIOGRAPHY AT THE NSLS.
    Suortti, P.
    Thomlinson, W.
    Nuclear instruments and methods in physics research, 1988, A269 (03): : 639 - 648
  • [3] A SINGLE-CRYSTAL BENT LAUE MONOCHROMATOR FOR CORONARY ANGIOGRAPHY
    SUORTTI, P
    THOMLINSON, W
    CHAPMAN, D
    GMUR, N
    SIDDONS, DP
    SCHULZE, C
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 336 (1-2): : 304 - 309
  • [4] DOUBLE-BEAM BENT LAUE MONOCHROMATOR FOR CORONARY ANGIOGRAPHY
    ILLING, G
    HEUER, J
    REIME, B
    LOHMANN, M
    MENK, RH
    SCHILDWACHTER, L
    DIX, WR
    GRAEFF, W
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (02): : 1379 - 1381
  • [5] A bent Laue-Laue monochromator for a synchrotron-based computed tomography system
    Ren, B
    Dilmanian, FA
    Chapman, LD
    Ivanov, I
    Wu, XY
    Zhong, Z
    Huang, X
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 428 (2-3): : 528 - 550
  • [6] An Energy Dispersive Bent Laue Monochromator for Kedge Subtraction Imaging
    Samadi, Nazanin
    Martinson, Mercedes
    Bassey, Bassey
    Gomez, Ariel
    Belev, George
    Chapman, Dean
    PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION (SRI2015), 2016, 1741
  • [7] A bent Laue crystal monochromator for monochromatic radiography with an area beam
    Zhong, Z
    Chapman, D
    Thomlinson, W
    Arfelli, F
    Menk, R
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 399 (2-3): : 489 - 498
  • [8] Bent Laue crystal monochromator for monochromatic radiography with an area beam
    Zhong, Z.
    Chapman, D.
    Thomlinson, W.
    Arfelli, F.
    Menk, R.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1997, 399 (2-3): : 489 - 498
  • [9] A High Quality Bent Crystal Monochromator based on Asymmetric Laue Geometry
    Hu, Hua-Chen
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2005, 61 : C142 - C142
  • [10] Characterization of a bent Laue double-crystal beam-expanding monochromator
    Martinson, Mercedes
    Samadi, Nazanin
    Shi, Xianbo
    Liu, Zunping
    Assoufid, Lahsen
    Chapman, Dean
    JOURNAL OF SYNCHROTRON RADIATION, 2017, 24 : 1146 - 1151