PERFORMANCE EVALUATION OF A BENT LAUE MONOCHROMATOR

被引:17
|
作者
SUORTTI, P [1 ]
THOMLINSON, W [1 ]
CHAPMAN, D [1 ]
GMUR, N [1 ]
GREENE, R [1 ]
LAZARZ, N [1 ]
机构
[1] BROOKHAVEN NATL LAB,NATL SYNCHROTRON LIGHT SOURCE,UPTON,NY 11973
基金
芬兰科学院;
关键词
D O I
10.1016/0168-9002(90)91375-L
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A prototype focusing Laue geometry dual-energy monochromator, designed for human coronary angiography, has been tested at the National Synchrotron Light Source. The monochromatic photon beams from (111) reflections from two cylindrically bent [100] wafers of silicon were adjusted such that the energy of one of the beams was just above the K edge of iodine and the other beam's energy was just below the edge. Focusing of the beams by the bent crystals was measured with photographic film. An incident beam 4 mm high was focused to a line less than 0.3 mm high at a distance of 3 m. The monochromatic flux was determined by measuring the integrated intensities of a standard Mo powder sample and was in excellent agreement with the theoretical estimates. The reflectivity of the crystals was enhanced due to bending by an order of magnitude over the dynamical value.
引用
收藏
页码:268 / 274
页数:7
相关论文
共 50 条
  • [21] A BENT NEUTRON COMB MONOCHROMATOR
    FREY, F
    ADLHART, W
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1980, 13 (05): : 483 - 486
  • [22] BENDING OF BENT MONOCHROMATOR CRYSTALS
    PENNARTZ, PU
    KOSTEN, K
    ARNOLD, H
    ZEITSCHRIFT FUR KRISTALLOGRAPHIE, 1988, 182 (1-4): : 206 - 207
  • [23] Development of a bent Laue beam-expanding double-crystal monochromator for biomedical X-ray imaging
    Martinson, Mercedes
    Samadi, Nazanin
    Belev, George
    Bassey, Bassey
    Lewis, Rob
    Aulakh, Gurpreet
    Chapman, Dean
    JOURNAL OF SYNCHROTRON RADIATION, 2014, 21 : 479 - 483
  • [24] XAFS WITH AN ENERGY-DISPERSIVE LAUE MONOCHROMATOR
    HAGELSTEIN, M
    FERRERO, C
    DELRIO, MS
    HATJE, U
    RESSLER, T
    METZ, W
    PHYSICA B, 1995, 208 (1-4): : 223 - 224
  • [25] Hard X-ray Laue monochromator
    Kocharyan, V. R.
    Gogolev, A. S.
    Kiziridi, A. A.
    Batranin, A. V.
    Muradyan, T. R.
    VIII INTERNATIONAL SCIENTIFIC CONFERENCE - ISSUES OF PHYSICS AND TECHNOLOGY IN SCIENCE, INDUSTRY AND MEDICINE, 2016, 135
  • [26] Characterization of bent crystals for Laue lenses
    Liccardo, V.
    Virgilli, E.
    Frontera, F.
    Valsan, V.
    SPACE TELESCOPES AND INSTRUMENTATION 2012: ULTRAVIOLET TO GAMMA RAY, 2012, 8443
  • [27] Designing and commissioning of a prototype double Laue monochromator at CHESS
    Ko, J. Y. Peter
    Oswald, Benjamin B.
    Savino, James J.
    Pauling, Alan K.
    Lyndaker, Aaron
    Revesz, Peter
    Miller, Matthew P.
    Brock, Joel D.
    17TH PAN-AMERICAN SYNCHROTRON RADIATION INSTRUMENTATION CONFERENCE SRI2013, 2014, 493
  • [28] A bent Laue analyzer for fluorescence EXAFS detection
    Zhong, Z
    Chapman, D
    Bunker, B
    Bunker, G
    Fischetti, R
    Segre, C
    JOURNAL OF SYNCHROTRON RADIATION, 1999, 6 : 212 - 214
  • [29] Ultrasound adjustable Laue-Laue double-crystal x-ray monochromator
    Polikarpov, I
    Panov, VV
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1999, 32 (16) : 2083 - 2086
  • [30] Study and characterization of bent crystals for Laue lenses
    Liccardo, Vincenzo
    Virgilli, Enrico
    Frontera, Filippo
    Valsan, Vineeth
    Buffagni, Elisa
    Ferrari, Claudio
    Bonnini, Elisa
    Zappettini, Andrea
    Guidi, Vincenzo
    Bellucci, Valerio
    Camattari, Riccardo
    EXPERIMENTAL ASTRONOMY, 2014, 38 (03) : 401 - 416