PERFORMANCE EVALUATION OF A BENT LAUE MONOCHROMATOR

被引:17
|
作者
SUORTTI, P [1 ]
THOMLINSON, W [1 ]
CHAPMAN, D [1 ]
GMUR, N [1 ]
GREENE, R [1 ]
LAZARZ, N [1 ]
机构
[1] BROOKHAVEN NATL LAB,NATL SYNCHROTRON LIGHT SOURCE,UPTON,NY 11973
基金
芬兰科学院;
关键词
D O I
10.1016/0168-9002(90)91375-L
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A prototype focusing Laue geometry dual-energy monochromator, designed for human coronary angiography, has been tested at the National Synchrotron Light Source. The monochromatic photon beams from (111) reflections from two cylindrically bent [100] wafers of silicon were adjusted such that the energy of one of the beams was just above the K edge of iodine and the other beam's energy was just below the edge. Focusing of the beams by the bent crystals was measured with photographic film. An incident beam 4 mm high was focused to a line less than 0.3 mm high at a distance of 3 m. The monochromatic flux was determined by measuring the integrated intensities of a standard Mo powder sample and was in excellent agreement with the theoretical estimates. The reflectivity of the crystals was enhanced due to bending by an order of magnitude over the dynamical value.
引用
收藏
页码:268 / 274
页数:7
相关论文
共 50 条
  • [11] Bent Laue crystal monochromator for producing areal x-ray beams
    Zhong, Z
    MEDICAL PHYSICS, 1997, 24 (12) : 2055 - 2055
  • [12] Bent Bragg-Laue monochromator for high-energy X-rays
    Shi, Xianbo
    Xu, Wenqian
    Yakovenko, Andrey
    Halder, Gregory
    Liu, Zunping
    Kurtz, Charles
    Ribaud, Lynn
    Beyer, Kevin
    Chapman, Karena
    Chupas, Peter
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2017, 50 : 1158 - 1164
  • [13] A bent Laue-Laue monochromator for a synchrotron-based monochromatic x-ray computed tomography system
    Ren, BR
    MEDICAL PHYSICS, 1998, 25 (12) : 2483 - 2483
  • [14] Monochromatic energy-subtraction radiography using a rotating anode source and a bent Laue monochromator
    Zhong, Z
    Chapman, D
    Menk, R
    Richardson, J
    Theophanis, S
    Thomlinson, W
    PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (09): : 1751 - 1762
  • [15] Evaluation of the focusing performance of bent Laue crystals using wave-optical theory
    Nesterets, Ya. I.
    Wilkins, S. W.
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2008, 41 : 237 - 248
  • [16] Expected performance of a Laue lens based on bent crystals
    Valsan, Vineeth
    Frontera, Filippo
    Virgilli, Enrico
    Liccardo, Vincenzo
    SPACE TELESCOPES AND INSTRUMENTATION 2012: ULTRAVIOLET TO GAMMA RAY, 2012, 8443
  • [17] Highly asymmetric Laue focusing monochromator
    Oberta, P.
    Mikulik, P.
    Hrdy, J.
    Kittler, M.
    SRI 2009: THE 10TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION, 2010, 1234 : 724 - +
  • [18] CONSTRUCTION AND PERFORMANCE OF A BENT CRYSTAL X-RAY MONOCHROMATOR
    STEPHENS, PW
    ENG, PJ
    TSE, T
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1993, 64 (02): : 374 - 378
  • [19] Simulation of bent Laue crystals for a high-energy X-ray monochromator with heat load consideration
    Wang, Jiayi
    Gao, Lidan
    Li, Ming
    Yang, Yiming
    Li, Yanchun
    Cheng, Hu
    Fan, Longlong
    Wang, Youkang
    Guo, Huilong
    Jia, Quanjie
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2025, 58 : 154 - 167
  • [20] A DOUBLY BENT SILICON MONOCHROMATOR
    WAGNER, V
    MIKULA, P
    LUKAS, P
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 338 (01): : 53 - 59