OPTIMIZATION OF OUTSIDE AIR COOLING IN DATA CENTERS

被引:0
|
作者
Kumari, Niru [1 ]
Shih, Rocky [1 ]
McReynolds, Alan [1 ]
Sharma, Ratnesh [1 ]
Christian, Tom [1 ]
Bash, Cullen [1 ]
机构
[1] Hewlett Packard Labs, Palo Alto, CA USA
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Airside economizers in data centers introducing outside air directly in cold aisles or at CRAC level have been considered recently to reduce overall energy to cool IT equipment. However, such designs limit the operational envelope of free cooling based on the required supply air temperature to the IT equipment. More studies are required to optimize airside economizer layouts to increase the operation time and hence, increase the energy savings. This paper presents a case study of different outside air delivery configurations including outside air introduced in cold aisles, in plenum close to CRAC units' supply side, at return side of CRAC units and in hot aisles. The temperature and flow fields are studied numerically and are compared to each other. Mixing of the cooler outside air with the hot air is studied to determine optimal local distribution of the outside air in a non-homogeneous data center to maximize natural cooling. The paper also quantifies the annual average performance of the outside air infrastructure to include the effects of the seasonal variations in the ambient temperature.
引用
收藏
页码:519 / 525
页数:7
相关论文
共 50 条
  • [41] Optimization of Water Consumption in Hybrid Evaporative Cooling Air Conditioning Systems for Data Center Cooling Applications
    Ndukaife, Theodore A.
    Nnanna, A. G. Agwu
    HEAT TRANSFER ENGINEERING, 2019, 40 (07) : 559 - 573
  • [42] ENERGY-EFFICIENT AIR COOLING OF DATA CENTERS AT 2000 W/FT2
    Herrlin, Magnus K.
    Patterson, Michael K.
    IPACK 2009: PROCEEDINGS OF THE ASME INTERPACK CONFERENCE 2009, VOL 2, 2010, : 875 - 880
  • [43] Research status and development trends of evaporative cooling air-conditioning technology in data centers
    Chu J.
    Huang X.
    Energy and Built Environment, 2023, 4 (01): : 86 - 110
  • [44] Thermal Management and Energy Consumption in Air, Liquid, and Free Cooling Systems for Data Centers: A Review
    Xu, Sijun
    Zhang, Hua
    Wang, Zilong
    ENERGIES, 2023, 16 (03)
  • [45] Analysis of Air Leakage from Hot Aisle Containment Systems and Cooling Efficiency of Data Centers
    Khankari, Kishor
    ASHRAE TRANSACTIONS 2014, VOL 120, PT 1, 2014, 120
  • [46] Gravity-assisted air mixing in data centers and how it affects the rack cooling effectiveness
    Herrlin, Magnus K.
    Belady, Christian
    2006 PROCEEDINGS 10TH INTERSOCIETY CONFERENCE ON THERMAL AND THERMOMECHANICAL PHENOMENA IN ELECTRONICS SYSTEMS, VOLS 1 AND 2, 2006, : 434 - +
  • [47] An open-source and experimentally guided CFD strategy for predicting air distribution in data centers with air-cooling
    Liu, Wei
    Lian, Song
    Fang, Xin
    Shang, Zhenyu
    Wu, Hao
    Zhu, Hao
    Hu, Simon
    BUILDING AND ENVIRONMENT, 2023, 242
  • [48] Controlling Air Pollution in Data Centers using Green Data Centers
    Dey, Sweta
    Pal, Sujata
    2023 IEEE/ACM 23RD INTERNATIONAL SYMPOSIUM ON CLUSTER, CLOUD AND INTERNET COMPUTING WORKSHOPS, CCGRIDW, 2023, : 200 - 205
  • [49] Airflow optimization in data centers
    Energy Engineering Lead Syserco Inc., United States
    Energy Eng, 3 (33-54): : 33 - 54
  • [50] Experimental investigation on evaporative cooling coupled phase change energy storage technology for data centers under natural air cooling
    Yi, Xiaoyan
    Xu, Hongli
    Mao, Ruiyong
    Wu, Hongwei
    Gao, Xiangkui
    Zhou, Jiri
    Zhang, Zujing
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2024, 159