OPTIMIZATION OF OUTSIDE AIR COOLING IN DATA CENTERS

被引:0
|
作者
Kumari, Niru [1 ]
Shih, Rocky [1 ]
McReynolds, Alan [1 ]
Sharma, Ratnesh [1 ]
Christian, Tom [1 ]
Bash, Cullen [1 ]
机构
[1] Hewlett Packard Labs, Palo Alto, CA USA
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Airside economizers in data centers introducing outside air directly in cold aisles or at CRAC level have been considered recently to reduce overall energy to cool IT equipment. However, such designs limit the operational envelope of free cooling based on the required supply air temperature to the IT equipment. More studies are required to optimize airside economizer layouts to increase the operation time and hence, increase the energy savings. This paper presents a case study of different outside air delivery configurations including outside air introduced in cold aisles, in plenum close to CRAC units' supply side, at return side of CRAC units and in hot aisles. The temperature and flow fields are studied numerically and are compared to each other. Mixing of the cooler outside air with the hot air is studied to determine optimal local distribution of the outside air in a non-homogeneous data center to maximize natural cooling. The paper also quantifies the annual average performance of the outside air infrastructure to include the effects of the seasonal variations in the ambient temperature.
引用
收藏
页码:519 / 525
页数:7
相关论文
共 50 条
  • [31] Energy saving analysis of evaporative cooling composite air conditioning system for data centers
    Han, Zongwei
    Sun, Xiaoqing
    Wei, Haotian
    Ji, Qiang
    Xue, Da
    APPLIED THERMAL ENGINEERING, 2021, 186
  • [32] Cooling architecture selection for air-cooled Data Centers by minimizing exergy destruction
    Gupta, Rohit
    Asgari, Sahar
    Moazamigoodarzi, Hosein
    Pal, Souvik
    Puri, Ishwar K.
    ENERGY, 2020, 201
  • [33] Enhancing Cooling Efficiency in Data Centers: An Evaluation of Heat Pipe Design in Air Ducts
    Piarah, Wahyu H.
    Yamani, Muhammad R.
    Djafar, Zulkifli
    Gunadin, Indar C.
    Muslimin, Zaenab
    Arminah, Bidayatul
    Setyawan, Iwan
    Djafar, Zuryati
    INTERNATIONAL JOURNAL OF HEAT AND TECHNOLOGY, 2024, 42 (01) : 263 - 269
  • [34] Development of modular air containment system: Thermal performance optimization of row-based cooling for high-density data centers
    Cho, Jinkyun
    Kim, Youngmo
    ENERGY, 2021, 231
  • [35] OPTIMIZATION OF AIR COOLERS AND AIR COOLING PLANTS
    BALIKO, S
    ENERGIA ES ATOMTECHNIKA, 1984, 37 (03): : 122 - 129
  • [36] Data centers roadmap for datacom cooling
    Belady, CL
    Beaty, D
    ASHRAE JOURNAL, 2005, 47 (12) : 52 - 55
  • [37] Free cooling of data centers: A review
    Zhang, Hainan
    Shao, Shuangquan
    Xu, Hongbo
    Zou, Huiming
    Tian, Changqing
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2014, 35 : 171 - 182
  • [38] Cooling-Aware Energy and Workload Management in Data Centers via Stochastic Optimization
    Chen, Tianyi
    Wang, Xin
    Giannakis, Georgios B.
    IEEE JOURNAL OF SELECTED TOPICS IN SIGNAL PROCESSING, 2016, 10 (02) : 402 - 415
  • [39] Joint Optimization of Idle and Cooling Power in Data Centers While Maintaining Response Time
    Ahmad, Faraz
    Vijaykumar, T. N.
    ASPLOS XV: FIFTEENTH INTERNATIONAL CONFERENCE ON ARCHITECTURAL SUPPORT FOR PROGRAMMING LANGUAGES AND OPERATING SYSTEMS, 2010, : 243 - 256
  • [40] Joint Optimization of Idle and Cooling Power in Data Centers While Maintaining Response Time
    Ahmad, Faraz
    Vijaykumar, T. N.
    ACM SIGPLAN NOTICES, 2010, 45 (03) : 243 - 256