OPTIMIZATION OF OUTSIDE AIR COOLING IN DATA CENTERS

被引:0
|
作者
Kumari, Niru [1 ]
Shih, Rocky [1 ]
McReynolds, Alan [1 ]
Sharma, Ratnesh [1 ]
Christian, Tom [1 ]
Bash, Cullen [1 ]
机构
[1] Hewlett Packard Labs, Palo Alto, CA USA
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Airside economizers in data centers introducing outside air directly in cold aisles or at CRAC level have been considered recently to reduce overall energy to cool IT equipment. However, such designs limit the operational envelope of free cooling based on the required supply air temperature to the IT equipment. More studies are required to optimize airside economizer layouts to increase the operation time and hence, increase the energy savings. This paper presents a case study of different outside air delivery configurations including outside air introduced in cold aisles, in plenum close to CRAC units' supply side, at return side of CRAC units and in hot aisles. The temperature and flow fields are studied numerically and are compared to each other. Mixing of the cooler outside air with the hot air is studied to determine optimal local distribution of the outside air in a non-homogeneous data center to maximize natural cooling. The paper also quantifies the annual average performance of the outside air infrastructure to include the effects of the seasonal variations in the ambient temperature.
引用
收藏
页码:519 / 525
页数:7
相关论文
共 50 条
  • [21] Evaluation of the cooling effectiveness of air-cooled data centers by energy diagram
    Li, Nan
    Li, Haowei
    Duan, Kaiwen
    Tao, Wen-Quan
    APPLIED ENERGY, 2025, 382
  • [22] Data Centers and Comfort Cooling
    Remmers, James H.
    ASHRAE JOURNAL, 2012, 54 (12) : 12 - 12
  • [23] Smart cooling of data centers
    Patel, CD
    Bash, CE
    Sharma, R
    Beitelmal, M
    Friedrich, R
    ADVANCES IN ELECTRONIC PACKAGING 2003, VOL 2, 2003, : 129 - 137
  • [24] Liquid Cooling in Data Centers
    Cader, Tahir
    Sorel, Vali
    Westra, Levi
    Marquez, Andres
    ASHRAE TRANSACTIONS 2009, VOL 115, PT 1, 2009, 115 : 231 - +
  • [25] Data Centers and Comfort Cooling
    Beaty, Don
    ASHRAE JOURNAL, 2012, 54 (10) : 86 - +
  • [26] Energy savings in direct air-side free cooling data centers: A cross-system modeling and optimization framework
    Zhou, Yongcheng
    Li, Shuangxiu
    Li, Qiang
    Wei, Fanchao
    Yang, Dazhi
    Liu, Jinfu
    Yu, Daren
    ENERGY AND BUILDINGS, 2024, 308
  • [27] Optimization Control Strategies and Evaluation Metrics of Cooling Systems in Data Centers: A Review
    Chang, Qiankun
    Huang, Yuanfeng
    Liu, Kaiyan
    Xu, Xin
    Zhao, Yaohua
    Pan, Song
    SUSTAINABILITY, 2024, 16 (16)
  • [28] Optimization of Cooling Energy Consumption in Data Centers Based on Mixed Integer Programming
    Zhang, Quan
    Zheng, Haoran
    Zhu, Yiqun
    Zou, Sikai
    Hunan Daxue Xuebao/Journal of Hunan University Natural Sciences, 2024, 51 (09): : 188 - 197
  • [29] Joint Energy Optimization of Cooling Systems and Virtual Machine Consolidation in Data Centers
    Liu, Hai
    Wong, Wai Kit
    Ye, Shujin
    Ma, Yu Tak Chris
    2020 29TH INTERNATIONAL CONFERENCE ON COMPUTER COMMUNICATIONS AND NETWORKS (ICCCN 2020), 2020,
  • [30] Field test of cooling systems in two air-cooled data centers: Various regions, air distributions and evaporative cooling technologies
    Jing, Yang
    Xie, Linfeng
    Li, Fangling
    Zhan, Ziyang
    Wang, Zhenghua
    Yang, Fan
    Fan, Jiale
    Zhu, Zihan
    Zhang, Hao
    Zhao, Ce
    Shi, Zhuofan
    Jiang, Haihua
    Xie, Xiaoyun
    Jiang, Yi
    APPLIED THERMAL ENGINEERING, 2024, 248