OPTIMIZATION OF OUTSIDE AIR COOLING IN DATA CENTERS

被引:0
|
作者
Kumari, Niru [1 ]
Shih, Rocky [1 ]
McReynolds, Alan [1 ]
Sharma, Ratnesh [1 ]
Christian, Tom [1 ]
Bash, Cullen [1 ]
机构
[1] Hewlett Packard Labs, Palo Alto, CA USA
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Airside economizers in data centers introducing outside air directly in cold aisles or at CRAC level have been considered recently to reduce overall energy to cool IT equipment. However, such designs limit the operational envelope of free cooling based on the required supply air temperature to the IT equipment. More studies are required to optimize airside economizer layouts to increase the operation time and hence, increase the energy savings. This paper presents a case study of different outside air delivery configurations including outside air introduced in cold aisles, in plenum close to CRAC units' supply side, at return side of CRAC units and in hot aisles. The temperature and flow fields are studied numerically and are compared to each other. Mixing of the cooler outside air with the hot air is studied to determine optimal local distribution of the outside air in a non-homogeneous data center to maximize natural cooling. The paper also quantifies the annual average performance of the outside air infrastructure to include the effects of the seasonal variations in the ambient temperature.
引用
收藏
页码:519 / 525
页数:7
相关论文
共 50 条
  • [1] Outside air inside data centers
    Systems and Controls Group, EYP Mission Critical Facilities
    不详
    Eng syst, 2008, 9 (76-80): : 76 - 80
  • [2] Coordinated Optimization of Cooling and IT Power in Data Centers
    Samadiani, Emad
    Amur, Hrishikesh
    Krishnan, Bhavani
    Joshi, Yogendra
    Schwan, Karsten
    JOURNAL OF ELECTRONIC PACKAGING, 2010, 132 (03)
  • [3] Optimization and Control of Cooling Microgrids for Data Centers
    Zhou, Rongliang
    Wang, Zhikui
    McReynolds, Alan
    Bash, Cullen E.
    Christian, Thomas W.
    Shih, Rocky
    2012 13TH IEEE INTERSOCIETY CONFERENCE ON THERMAL AND THERMOMECHANICAL PHENOMENA IN ELECTRONIC SYSTEMS (ITHERM), 2012, : 338 - 343
  • [4] Optimization of cluster cooling performance for data centers
    Shrivastava, Saurabh K.
    VanGilder, James W.
    Sammakia, Bahgat G.
    2008 11TH IEEE INTERSOCIETY CONFERENCE ON THERMAL AND THERMOMECHANICAL PHENOMENA IN ELECTRONIC SYSTEMS, VOLS 1-3, 2008, : 1161 - +
  • [5] Optimization and control of cooling microgrids for data centers
    Zhou, R. (Rongliang.Zhou@hp.com), 1600, Hewlett Packard Laboratories
  • [6] Modeling of air conditioning systems for cooling of data centers
    Anton, R
    Jonsson, H
    Palm, B
    ITHERM 2002: EIGHTH INTERSOCIETY CONFERENCE ON THERMAL AND THERMOMECHANICAL PHENOMENA IN ELECTRONIC SYSTEMS, PROCEEDINGS, 2002, : 552 - 558
  • [7] Energy efficiency optimization analysis for a cooling composite air conditioning system for internet data centers
    Li, Zhao
    Tong, Jihua
    Zheng, Zhuling
    Dong, Pengli
    Yang, Shangqing
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2024, 30 (09) : 1167 - 1181
  • [8] Study on Outside Air Cooling Systems Used in Data Processing Facilities
    Yamaguchi, Iwao
    Koganei, Makoto
    Goto, Tomonobu
    Tsushima, Masataka
    JOURNAL OF ASIAN ARCHITECTURE AND BUILDING ENGINEERING, 2012, 11 (01) : 219 - 223
  • [9] Genetic algorithm based cooling energy optimization of data centers
    Athavale, Jayati
    Yoda, Minami
    Joshi, Yogendra
    INTERNATIONAL JOURNAL OF NUMERICAL METHODS FOR HEAT & FLUID FLOW, 2021, 31 (10) : 3148 - 3168
  • [10] DETERMINING OUTSIDE AIR COOLING LOADS
    SISSON, W
    PLANT ENGINEERING, 1978, 32 (12) : 145 - 147