Quantitative accuracy of attenuation correction in the Philips Ingenuity TF whole-body PET/MR system: a direct comparison with transmission-based attenuation correction

被引:52
|
作者
Schramm, Georg [1 ]
Langner, Jens [1 ]
Hofheinz, Frank [1 ]
Petr, Jan [1 ]
Beuthien-Baumann, Bettina [2 ]
Platzek, Ivan [3 ]
Steinbach, Joerg [1 ]
Kotzerke, Joerg [2 ]
van den Hoff, Joerg [1 ,2 ]
机构
[1] Helmholtz Zentrum Dresden Rossendorf, PET Ctr, Inst Radiopharm, Dresden, Germany
[2] Tech Univ Dresden, Dept Nucl Med, Univ Hosp Carl Gustav Carus, D-01062 Dresden, Germany
[3] Tech Univ Dresden, Dept Radiol, Univ Hosp Carl Gustav Carus, D-01062 Dresden, Germany
关键词
PET/MR; MR-based attenuation correction; PET quantification; PERFORMANCE EVALUATION; NEXT-GENERATION; MRI; IMAGES; CT;
D O I
10.1007/s10334-012-0328-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Evaluation of the quantitative accuracy of MR-based attenuation correction (MRAC) in the Philips Ingenuity TF whole-body PET/MR. In 13 patients, PET emission data from the PET/MR were reconstructed using two different methods for attenuation correction. In the first reconstruction, the vendor-provided standard MRAC was used. In the second reconstruction, a coregistered transmission-based attenuation map from a second immediately preceding investigation with a stand-alone Siemens ECAT EXACT HR+ PET scanner was used (TRAC). The two attenuation maps were compared regarding occurrence of segmentation artifacts in the MRAC procedure. Standard uptake values (SUVs) of multiple VOIs (liver, cerebellum, hot focal structures at various locations in the trunk) were compared between both reconstructed data sets. Furthermore, a voxel-wise intensity correlation analysis of both data sets in the lung and trunk was performed. VOI averaged SUV differences between MRAC and TRAC were as follows (relative differences, mean +/- A standard deviation): (+12 +/- A 6) % cerebellum, (-4 +/- A 9) % liver, (-2 +/- A 11) % hot focal structures. The fitted slopes of the voxel-wise correlations in the lung and trunk were 0.87 +/- A 0.17 and 0.95 +/- A 0.10 with averaged adjusted R (2) values of 0.96 and 0.98, respectively. These figures include two instances with partially erroneous lung segmentation due to artifacts in the underlying MR images. The MR-based attenuation correction implemented on the Philips Ingenuity PET/MR provides reasonable quantitative accuracy. On average, deviations from TRAC-based results are small (on the order of 10 % or below) across the trunk, but due to interindividual variability of the segmentation quality, deviations of more than 20 % can occur. Future improvement of the segmentation quality would help to increase the quantitation accuracy further and to reduce the inter-subject variability.
引用
收藏
页码:115 / 126
页数:12
相关论文
共 50 条
  • [41] Whole body pet attenuation correction with transmission image segmentation.
    Chatziioannou, A
    Dahlbom, M
    Hoh, CK
    JOURNAL OF NUCLEAR MEDICINE, 1996, 37 (05) : 20 - 20
  • [42] Validation of quantitative accuracy of the post-injection transmission-based and transmissionless attenuation correction techniques in neurological FDG-PET
    Kanebo, K
    Kuwabara, Y
    Sasaki, M
    Koga, H
    Abe, K
    Baba, S
    Hayashi, K
    Honda, H
    NUCLEAR MEDICINE COMMUNICATIONS, 2004, 25 (11) : 1095 - 1102
  • [43] A deep learning-based whole-body solution for PET/MRI attenuation correction
    Sahar Ahangari
    Anders Beck Olin
    Marianne Kinggård Federspiel
    Bjoern Jakoby
    Thomas Lund Andersen
    Adam Espe Hansen
    Barbara Malene Fischer
    Flemming Littrup Andersen
    EJNMMI Physics, 9
  • [44] Fuzzy clustering-based segmented attenuation correction in whole-body PET imaging
    Zaidi, H
    Diaz-Gomez, M
    Boudraa, A
    Slosman, DO
    PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (07): : 1143 - 1160
  • [45] A deep learning-based whole-body solution for PET/MRI attenuation correction
    Ahangari, Sahar
    Olin, Anders Beck
    Federspiel, Marianne Kinggard
    Jakoby, Bjoern
    Andersen, Thomas Lund
    Hansen, Adam Espe
    Fischer, Barbara Malene
    Andersen, Flemming Littrup
    EJNMMI PHYSICS, 2022, 9 (01)
  • [46] Quantitative evaluation of atlas-based MR attenuation correction for brain PET imaging using a time-of-flight PET/MRI system: A direct comparison with CT-based attenuation correction
    Yang, Jaewon
    Tohme, Michel
    Jian, Yiqiang
    Behr, Spencer
    Vigneron, Daniel
    Majumdar, Sharmila
    Seo, Youngho
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (03)
  • [47] Comparison of MR Based Attenuation Correction Methods with CT Based Attenuation Correction in Dynamic Brain PET imaging
    Firouzian, A.
    Delso, G.
    Hallett, W.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 45 : S695 - S696
  • [48] Accuracy of a new atlas-based attenuation correction method in comparison to standard MR-based attenuation correction of the skull region in PET/MR imaging
    Rausch, I.
    Rischka, L.
    Ladefoged, C. N.
    Fenchel, M.
    Hahn, A.
    Lanzenberger, R.
    Traub-Weidinger, T.
    Beyer, T.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 : S78 - S78
  • [49] Accuracy and reproducibility of standard MR-based attenuation maps of the thorax: An inter-system comparison of whole-body PET/MR systems
    Lassen, M. L.
    Quick, H.
    Boellaard, R.
    Delso, G.
    Rausch, I.
    Sattler, B.
    Yaqub, M.
    Ziegler, S.
    Beyer, T.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 : S408 - S408
  • [50] Attenuation correction with the watershed segmentation algorithm for whole-body PET imaging.
    Riddell, CA
    Brigger, P
    Libutti, SK
    Bacharach, SL
    JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (05) : 294P - 294P