A deep learning-based whole-body solution for PET/MRI attenuation correction

被引:8
|
作者
Ahangari, Sahar [1 ,2 ]
Olin, Anders Beck [1 ,2 ]
Federspiel, Marianne Kinggard [1 ,2 ]
Jakoby, Bjoern [3 ]
Andersen, Thomas Lund [1 ,2 ]
Hansen, Adam Espe [1 ,2 ,4 ,5 ]
Fischer, Barbara Malene [1 ,2 ,4 ]
Andersen, Flemming Littrup [1 ,2 ,4 ]
机构
[1] Rigshosp, Dept Clin Physiol, Nucl Med, Copenhagen, Denmark
[2] Rigshosp, PET, Copenhagen, Denmark
[3] Siemens Healthcare GmbH, Erlangen, Germany
[4] Univ Copenhagen, Dept Clin Med, Copenhagen, Denmark
[5] Rigshosp, Dept Diagnost Radiol, Copenhagen, Denmark
基金
欧盟地平线“2020”;
关键词
PET; MRI; MR-AC; Attenuation correction; Deep learning; Whole body; QUANTITATIVE-EVALUATION; MRI; TRUNCATION;
D O I
10.1186/s40658-022-00486-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Deep convolutional neural networks have demonstrated robust and reliable PET attenuation correction (AC) as an alternative to conventional AC methods in integrated PET/MRI systems. However, its whole-body implementation is still challenging due to anatomical variations and the limited MRI field of view. The aim of this study is to investigate a deep learning (DL) method to generate voxel-based synthetic CT (sCT) from Dixon MRI and use it as a whole-body solution for PET AC in a PET/MRI system. Materials and methods Fifteen patients underwent PET/CT followed by PET/MRI with whole-body coverage from skull to feet. We performed MRI truncation correction and employed co-registered MRI and CT images for training and leave-one-out cross-validation. The network was pretrained with region-specific images. The accuracy of the AC maps and reconstructed PET images were assessed by performing a voxel-wise analysis and calculating the quantification error in SUV obtained using DL-based sCT (PETsCT) and a vendor-provided atlas-based method (PETAtlas), with the CT-based reconstruction (PETCT) serving as the reference. In addition, region-specific analysis was performed to compare the performances of the methods in brain, lung, liver, spine, pelvic bone, and aorta. Results Our DL-based method resulted in better estimates of AC maps with a mean absolute error of 62 HU, compared to 109 HU for the atlas-based method. We found an excellent voxel-by-voxel correlation between PETCT and PETsCT (R-2 = 0.98). The absolute percentage difference in PET quantification for the entire image was 6.1% for PETsCT and 11.2% for PETAtlas. The regional analysis showed that the average errors and the variability for PETsCT were lower than PETAtlas in all regions. The largest errors were observed in the lung, while the smallest biases were observed in the brain and liver. Conclusions Experimental results demonstrated that a DL approach for whole-body PET AC in PET/MRI is feasible and allows for more accurate results compared with conventional methods. Further evaluation using a larger training cohort is required for more accurate and robust performance.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] A deep learning-based whole-body solution for PET/MRI attenuation correction
    Sahar Ahangari
    Anders Beck Olin
    Marianne Kinggård Federspiel
    Bjoern Jakoby
    Thomas Lund Andersen
    Adam Espe Hansen
    Barbara Malene Fischer
    Flemming Littrup Andersen
    EJNMMI Physics, 9
  • [2] A deep learning-based approach for direct whole-body PET attenuation correction.
    Van Hemmen, Helena
    Massa, Haley
    Hurley, Samuel
    Cho, Steve
    Bradshaw, Tyler
    McMillan, Alan
    JOURNAL OF NUCLEAR MEDICINE, 2019, 60
  • [3] Deep learning based attenuation correction for whole-body PET studies
    Hwang, Donghwi
    Kim, Kyeong Yun
    Kang, Seung Kwan
    Seo, Seongho
    Paeng, Jin Chul
    Lee, Dong Soo
    Lee, Jae Sung
    JOURNAL OF NUCLEAR MEDICINE, 2018, 59
  • [4] JACK KROHMER JUNIOR INVESTIGATOR COMPETITION WINNER: Deep Learning-Based Self Attenuation Correction for Whole-Body PET Imaging
    Dong, X.
    Lei, Y.
    Wang, T.
    Higgins, K.
    Liu, T.
    Curran, W.
    Mao, H.
    Nye, J.
    Yang, X.
    MEDICAL PHYSICS, 2019, 46 (06) : E192 - E192
  • [5] Deep learning-based attenuation correction in the absence of structural information for whole-body positron emission tomography imaging
    Dong, Xue
    Lei, Yang
    Wang, Tonghe
    Higgins, Kristin
    Liu, Tian
    Curran, Walter J.
    Mao, Hui
    Nye, Jonathon A.
    Yang, Xiaofeng
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (05):
  • [6] PHOTON ATTENUATION CORRECTION IN WHOLE-BODY PET/MRI USING TISSUE CLASSIFICATION
    Martinez-Moeller, Axel
    Souvatzoglou, Michael
    Nekolla, Stephan G.
    2010 7TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, 2010, : 1061 - 1062
  • [7] Variable Lung Density Consideration in Attenuation Correction of Whole-Body PET/MRI
    Marshall, Harry R.
    Prato, Frank S.
    Deans, Lela
    Theberge, Jean
    Thompson, R. Terry
    Stodilka, Robert Z.
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53 (06) : 977 - 984
  • [9] Three-region MRI-based whole-body attenuation correction for automated PET reconstruction
    Steinberg, Jeffrey
    Jia, Guang
    Sammet, Steffen
    Zhang, Jun
    Hall, Nathan
    Knopp, Michael V.
    NUCLEAR MEDICINE AND BIOLOGY, 2010, 37 (02) : 227 - 235
  • [10] Whole-body PET/MRI: The effect of bone attenuation during MR-based attenuation correction in oncology imaging
    Aznar, M. C.
    Sersar, R.
    Saabye, J.
    Ladefoged, C. N.
    Andersen, F. L.
    Rasmussen, J. H.
    Lofgren, J.
    Beyer, T.
    EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (07) : 1177 - 1183